Schneider Electric I/O & Function Modules
Schneider Electric 140DAI34000C
Discrete input module
Genuine surplus Schneider Electric 140DAI34000C discrete input module for Modicon Quantum — 16 channels at 24 V AC, verified and ready to source.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Input Channels | 16 |
|---|---|
| Input Voltage | 24 V AC |
| Input Current | 10.7 to 12 mA |
| Max Leakage Current | 1.9 mA |
| Bus Current Requirement | 180 mA |
| Max Power Dissipation | 5.5 W |
| Addressing Requirement | 1 input word |
| Ambient Temperature | 0 to 60 °C |
| Standards | UL 508, CSA |
Description
The Schneider Electric 140DAI34000C is a 16-channel discrete input module for the Modicon Quantum platform, built for 24 V AC field signals. Maintenance and procurement teams choose genuine surplus or refurbished units of this module when they need a verified replacement without waiting on OEM lead times or paying full list price.
What This Modicon Quantum Module Does
The 140DAI34000C sits in the Modicon Quantum I/O lineup and accepts sixteen discrete inputs at 24 V AC. Each module occupies one input word in the controller’s addressing scheme, which keeps integration predictable for engineers maintaining existing Quantum racks. Input current runs from 10.7 to 12 mA, and maximum leakage current is held to 1.9 mA — a practical figure when you need to avoid false signal pickup from long field wiring. The module draws 180 mA from the bus and dissipates up to 5.5 W. It carries CE marking and is built to UL 508 and CSA standards, with an ambient operating range of 0 to 60 °C.

Why Genuine Surplus Fits This Module
Quantum installations are long-lived, and the discrete input cards inside them are often the parts that fail first or get damaged during field work. Sourcing a genuine replacement through OEM channels can mean extended lead times on a platform that is no longer the newest line. Autronexa stocks surplus and refurbished units of this module, each tested against OEM datasheet specifications and functionally verified by our sourcing team. That means you get a real Schneider Electric module — not a clone — with condition confirmed before it ships. For maintenance managers holding a line together, the difference between a verified surplus card and an uncertain grey-market unit is the difference between a planned swap and a second outage.

Sourcing Checklist Before You Order
Before committing, confirm the exact part number and revision on the module you are replacing, since Quantum racks can carry mixed generations. Decide whether your application needs surplus or refurbished condition, and check that your field devices match the 24 V AC input rating — this is an AC input card, not a DC variant. Review the addressing requirement against your existing configuration so the new module drops into the same input word. Autronexa can cross-reference markings and part numbers to confirm authenticity, and our team works with Allen-Bradley, Bently Nevada, Siemens and Schneider systems daily. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 140DAI34000C, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it is listed. The module you receive is a genuine Schneider Electric unit, not a copy.
What condition will the module arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — confirm the condition you need when you request a quote.
How fast can you ship the 140DAI34000C?
Lead time depends on current stock. Contact Autronexa with your part number and we will confirm availability and the shipping schedule for your order.
Does this module work in an existing Modicon Quantum rack?
Yes — it is a standard-format Modicon Quantum discrete input module occupying one input word. Confirm your rack generation and addressing configuration with our team before ordering.
Is the 140DAI34000C still supported by Schneider Electric?
Lifecycle status is not stated in our current data. Contact Autronexa to verify OEM support status and availability before you commit to a replacement plan.
Related & compatible parts
Schneider Electric
TM3AQ4
Genuine surplus Schneider Electric TM3AQ4 analog output module — 4 channels, 12-bit, verified condition and ready sourcing support.
Schneider Electric
140NOE25110C
Genuine surplus Schneider Electric 140NOE25110C TCP/IP module for Modicon Quantum — 8 channels, fiber support, verified condition.
Schneider Electric
ATV71HU22N4
Genuine surplus Schneider ATV71HU22N4 Altivar 71 drive, 2.2 kW, 380-480 VAC. Verified condition, faster lead time than OEM.
Schneider Electric
PC-L984-785
Genuine surplus Schneider Electric PC-L984-785 Compact CPU with 24k logic memory, Modbus ports, and verified condition from Autronexa.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…