Allen-Bradley I/O & Function Modules 1756 ControlLogix Series
Allen-Bradley 1756-OA8D
I/O & Function Modules
Allen-Bradley 1756-OA8D I/O & Function Modules. Module: Type Diagnostic AC Output Module; Outputs: 8 Diagnostic.
- New Surplus
- Available on request
Availability & pricing
| Condition | Price | Stock / lead time | Action |
|---|---|---|---|
| New Surplus | On request | Available on request |
Ships within 7 business days
Technical specifications
| Manufacturer | Rockwell Automation |
|---|---|
| Brand | Allen-Bradley |
| Part Number/Catalog No. | 1756-OA8D |
| Series | ControlLogix |
| Module | Type Diagnostic AC Output Module |
| Outputs | 8 Diagnostic |
| Voltage | 120 Volts AC |
| Operating Voltage Range | 74-132 Volts AC |
| Maximum Output Current Rating-Point | 1 Amp at 30 degrees Celsius, 0.5 Amps at 60 degrees Celsius |
| Maximum Output Current Rating-Module | 8 Amps at 30 degrees Celsius and 4 Amps at 60 degrees Celsius |
| Power Dissipation | (Max) 5.3 Watts at 60 degrees Celsius |
| Backplane Current | at 5 Volts 175 milliamps |
| Backplane Current | at 24 Volts 250 milliamps |
| Removeable Terminal Block(s) | 1756-TBNH, 1756-TBSH |
| Isolation Voltage | 50 Volts Continuous |
| Enclosure | None |
| UPC | 10612598164520 Description |
Description
The Rockwell Automation 1756-OA8D is a catalog part supplied for replacement and new-build use in industrial control installations. Every rating below is taken from the manufacturer documentation for this part number. Headline figures: voltage 120 Volts AC
Electrical Ratings
Outputs is 8 Diagnostic. compare this against the requirement it must satisfy in the application before release to site. Voltage is 120 Volts AC. match this against the supply available at the installation site, including any tolerance on the incoming feed. Operating Voltage Range is 74-132 Volts AC. match this against the supply available at the installation site, including any tolerance on the incoming feed. Maximum Output Current Rating-Point is 1 Amp at 30 degrees Celsius, 0.5 Amps at 60 degrees Celsius. confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Maximum Output Current Rating-Module is 8 Amps at 30 degrees Celsius and 4 Amps at 60 degrees Celsius. confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Power Dissipation is (Max) 5.3 Watts at 60 degrees Celsius. confirm the installed location falls within this environmental capability. Backplane Current is at 5 Volts 175 milliamps. confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Backplane Current is at 24 Volts 250 milliamps. confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Isolation Voltage is 50 Volts Continuous. match this against the supply available at the installation site, including any tolerance on the incoming feed.
Additional Verified Data
Part Number/Catalog No. is 1756-OA8D. Module is Type Diagnostic AC Output Module. Removeable Terminal Block(s) is 1756-TBNH, 1756-TBSH.
Models in This Series
Autronexa currently lists this product entry as the only model in its entry. Cross-reference requests for equivalent or superseded part numbers are handled on request.
Confirming the Correct Variant Before Ordering
Read the part number marked on the unit being replaced and compare it character by character with the ordering code above, including any option suffix. Check the values in the technical specification table of this page against the nameplate on the existing unit rather than against a previous purchase record. Confirm the voltage available at the installation site is 120 Volts AC, which is the documented requirement for this model.
Request a Quote
Rockwell Automation supplies the 1756-OA8D as a quote-based item. Send the part number, quantity and destination for current stock, lead time and pricing; no fixed price is published for this part.
Frequently asked questions
What is the 1756-OA8D?
Allen-Bradley 1756-OA8D is an industrial automation component we supply from surplus and refurbished stock. Confirm the exact configuration, condition and lead time with our team before purchase.
Is the 1756-OA8D in stock, and what is the lead time?
We list the 1756-OA8D as in stock in New Surplus condition. Request a quote for current availability, pricing and confirmed lead time — most items ship within 1–3 business days.
Do you provide a datasheet for the 1756-OA8D?
Where available, the product page links the original manufacturer datasheet (PDF). Use the request-a-quote form to receive the full documentation pack and compliance information.
Can the 1756-OA8D be cross-referenced to an equivalent?
Many automation parts have equivalents or legacy replacements. Send us the 1756-OA8D together with your application details and we will confirm compatibility and alternatives.
What input voltage does the 1756-OA8D use?
The Rockwell Automation 1756-OA8D operates at 120 Volts AC. Verify the exact range and any hazardous-area limits against the product label before installation, because input requirements vary by ordered variant.
What is the 1756-OA8D and what is it used for?
The Rockwell Automation 1756-OA8D is a Type Diagnostic AC Output Module device. It is used in industrial control and automation systems where a verified part number and specification match are required for replacement or new design.
What supply voltage does the 1756-OA8D need?
The manufacturer documentation lists voltage 120 Volts AC. for this model. Confirm the supply at the installation site matches, including any tolerance on the incoming feed, before the part is ordered.
Related & compatible parts
Allen-Bradley
150-F108NBD
Genuine surplus Allen-Bradley 150-F108NBD SMC Flex motor controller, verified and ready to ship with sourcing support from Autronexa.
Allen-Bradley
22C-D045A103
Genuine surplus Allen-Bradley 22C-D045A103 PowerFlex 400 drive: 22 kW, 45.5 A, 380–480V AC, IP30, RS-485. Verified condition and…
Allen-Bradley
22C-B033F103
Genuine surplus Allen-Bradley 22C-B033F103 PowerFlex 400 drive: 7.5 kW, 33 A, 200…240V AC three-phase, IP20 flange mount, RS-485…
Allen-Bradley
150-F108NCR
Genuine surplus Allen-Bradley 150-F108NCR solid state controller with 108 A rating and 200-575V AC input — verified and…
News & guides for Allen-Bradley
Allen-Bradley spare parts: buying guide, series overview and how to order
Allen-Bradley spare parts buying guide: 16 parts online, popular series, condition options and how our RFQ process works.
Allen-Bradley spare parts: how to confirm the exact replacement
Specifying the correct Allen-Bradley replacement starts with the exact catalog number, not just the family. A 2097-Kinetix drive, a 1746…
SMC-Flex 150-F Soft Starter Guide: Current Frames, Control Voltage and Lug Kits
SMC-Flex soft starters are usually replaced after a trip that will not reset, not after a planned upgrade. That puts…
PowerFlex 400 (22C) Selection Guide: Catalog Codes, Ratings and Enclosures
A PowerFlex 400 purchase is rarely a question about the family. It is a question about which of the 20…
Rockwell 1718/1719-AENTR DoS: CVE-2026-9140 and the 3.012 Fix
Rockwell SD1778: a UDP unicast storm can knock 1718/1719 Ex I/O EtherNet/IP adapters offline until a power cycle. CVE-2026-9140 scores…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Rockwell CompactLogix 5390: 43% Smaller, 128 Axes, Built-In Security
Rockwell's CompactLogix 5390 is 43% smaller than the 5380, with 128 motion axes, 32 PointMax I/O modules and IEC 62443-4-2…
22 Powerflex series guide: configurations in stock and how to order
All 22 Powerflex configurations listed on this site, ordering notes for New Surplus parts, and answers to the most common…