SMC-Flex 150-F Soft Starter Guide: Current Frames, Control Voltage and Lug Kits

SMC-Flex soft starters are usually replaced after a trip that will not reset, not after a planned upgrade. That puts the burden on identification: the replacement has to repeat the amp frame, the line voltage class and the control voltage of the unit already wired into the cabinet.

The 20 catalog numbers below come from this site’s own product records. Ratings are quoted only where the product page records them, and the two records with incomplete spec tables are named rather than filled in.

How do you read a Bulletin 150 SMC-Flex catalog number?

A 150-F catalog number breaks into three blocks: the 150 prefix identifies the SMC-Flex solid-state controller, the digits after the dash give the amp frame, and the trailing letters separate line-voltage class from control voltage, which is why 150-F108FBD and 150-F108FAD share 108 A but not input voltage.

  • 150-F is the SMC-Flex solid-state controller prefix on all 20 catalog numbers listed here.
  • The digits give the amp frame: 108, 780 or 1250 A. Thirteen models are 108 A, one is 780 A and six are 1250 A.
  • On 108 A units the last letter separates control supply: D is 100…240 V AC and R is 24 V AC/DC.
  • On 1250 A units the same position separates 230/240 V AC (A) from 110/120 V AC (E).
  • A factory option string can follow the base number, as in 150-F108FBD-3-6P-HC3; the product page does not decode that string, so quote it in full.

Which 150-F models does this catalogue list?

This catalogue lists 20 SMC-Flex catalog numbers across three current frames: 108 A units rated up to 75 HP at 460 V AC, one 780 A unit rated 600 HP, and six 1250 A units rated 1000 HP at 460 V AC, in both enclosed and open construction.

  • 108 A frame: 13 catalog numbers, covering 200…208 V, 230 V, 400…460 V, 500…575 V and 230…690 V classes.
  • 1250 A frame: 6 catalog numbers, 1000 HP at 460 V AC, split between 200…460 V and 200…575 V classes.
  • 780 A frame: one catalog number, 150-F780JBE, 600 HP at 460 V AC in an IP54 (Type 12) enclosure.
  • 150-F1250NBED has no spec table on the site and 150-F108NBDD records voltage and enclosure only, so neither is quoted for power.
Catalog numberCurrentPowerLine voltageControl voltageEnclosure
150-F108FAD108 A—230V AC, 3-phase, 50 and 60 Hz100-240V AC (5-480 A units)IP65 (Type 4/12)
150-F108FBD108 A—400-460V AC, 3-phase, 50 and 60 Hz100-240V AC (5-480 A units)IP65 (Type 4/12)
150-F108FBD-3-6P-HC3108 A75 HP200 – 460 V AC100 – 240 V ACOpen Construction
150-F108FCD108 A—500-575V AC, 3-phase, 50 and 60 Hz100-240V AC (5-480 A units)IP65 (Type 4/12)
150-F108FHD108 A—200-208V AC, 3-phase, 50 and 60 Hz100-240V AC (5-480 A units)IP65 (Type 4/12)
150-F108NBD108 A75 HP at 460 VAC200-460 VAC, 3-Phase, 50/60 Hz100…240 V AC (5…480 A units)Open Type
150-F108NBDB108 A75 HP200 – 460 V AC100 – 240 V ACOpen Construction
150-F108NBDD108 A—200–460 VAC, 3-Phase, 50/60 Hz100–240 VACOpen Type
150-F108NBR108 A—200-460V AC, 3-phase, 50 and 60 Hz24V AC/DC (5-480 A units)Open
150-F108NBRB108 A—200…480 V AC (-15%, +10%) per UL/CSA/NEMA24 V AC at 50/60 Hz, 24 V DCOpen type
150-F108NCD108 A75 Hp at 460 V AC200–575 V AC, 3-phase, 50 and 60 Hz100–240 V AC (5–480 A units)Open
150-F108NCR108 A—200-575V AC, 3-phase, 50 and 60 Hz24V AC/DC (5-480 A units)Open
150-F108NZD108 A—230-690V AC, 3-phase, 50 and 60 Hz100-240V AC (5-480 A units)Open
150-F780JBE780 A—400-460V AC, 3-phase, 50 and 60 Hz110/120V AC (625-1250 A units)—
150-F1250NBA1250 A—200-460V AC, 3-phase, 50 and 60 Hz230/240V AC (625-1250 A units)open
150-F1250NBAB1250 A1000 Hp @ 460V AC200..480V AC, 3-Phase, 50/60Hz230…240V ACOpen
150-F1250NBE1250 A—200-460V AC, 3-phase, 50 and 60 Hz110/120V AC (625-1250 A units)Open
150-F1250NCA1250 A—200-575V AC, 3-phase, 50 and 60 Hz230/240V AC (625-1250 A units)Open
150-F1250NCE1250 A—200-575V AC, 3-phase, 50 and 60 Hz110/120V AC (625-1250 A units)Open

A blank cell means the product page does not record that field. It has not been filled from a neighbouring model.

What changes between the D and R control-voltage suffixes?

On the 108 A frame the final letter changes the control supply, not the power section. Models ending in D take 100…240 V AC control, while models ending in R take 24 V AC at 50/60 Hz or 24 V DC, and both are rated 108 A and 75 HP at 460 V AC.

  • 150-F108NBD: 108 A, 200…460 V AC line, 100…240 V AC control, open type.
  • 150-F108NBR: 108 A, 200…460 V AC line, 24 V AC/DC control, open type.
  • 150-F108NCD and 150-F108NCR repeat the same split on the 200…575 V AC class.
  • 150-F108NBRB adds a recorded trip-class range of 10, 15, 20 and 30 on top of the 24 V control supply.

What is the difference between the F-series and N-series SMC-Flex controllers?

F-series numbers such as 150-F108FBD ship in an IP65 (Type 4/12) enclosure that can be mounted without a separate cabinet, while N-series numbers such as 150-F108NBD are open construction, intended for installation inside existing switchgear where the enclosure rating comes from the cabinet rather than the starter.

  • Enclosed IP65 (Type 4/12), 108 A: 150-F108FAD, 150-F108FBD, 150-F108FCD, 150-F108FHD.
  • Open construction, 108 A: 150-F108NBD, 150-F108NBDB, 150-F108NBR, 150-F108NBRB, 150-F108NCD, 150-F108NCR, 150-F108NZD.
  • One exception to the pattern: 150-F780JBE is listed as IP54 (Type 12) rather than IP65, on the 780 A frame.
  • All six 1250 A models are open construction.

Which line-voltage classes are covered?

The 108 A frame covers five line-voltage classes — 200…208 V, 230 V, 400…460 V, 500…575 V and 230…690 V — while the 1250 A frame covers two, 200…460 V and 200…575 V, and the single 780 A unit is 400…460 V.

  • 200…208 V: 150-F108FHD. 230 V: 150-F108FAD. 400…460 V: 150-F108FBD. 500…575 V: 150-F108FCD.
  • 230…690 V: 150-F108NZD, the widest band recorded on any 108 A model.
  • 1250 A: 150-F1250NBA, 150-F1250NBAB and 150-F1250NBE are 200…460 V; 150-F1250NCA and 150-F1250NCE are 200…575 V.
  • The line-voltage class, not the amp frame, decides whether a unit suits a 690 V or a 575 V system.

Which lug kits fit SMC-Flex controllers?

Two SMC-Flex lug kits are listed. 100-DL860 accepts #2/0 to 500 MCM cable and ships as four tin-plated copper lugs rated 600 V with UL 94 V-0 insulation, while 100-DL630 is the IP20 / NEMA 1 terminal lug kit recorded for a 40 °C maximum ambient.

  • 100-DL860: #2/0 through 500 MCM, four tin-plated copper lugs, 600 VAC insulation rating, UL 94 V-0, −40 °C to +105 °C, 13.56 lbs (6.15 kg).
  • 100-DL860 also lists three heat-shrink insulating sleeves, types 193-EC_H and 193-EE_H.
  • 100-DL630: IP20 / NEMA 1, 0 °C to 40 °C ambient, 95 % maximum non-condensing humidity, 5.00 lbs (2.27 kg).
  • Both kits are separate catalog numbers, so the lug kit has to be ordered alongside the starter rather than assumed inside it.

How do you match a 150-F replacement to the existing starter?

Match three fields from the nameplate before ordering: the full catalog number, the amp frame and the control voltage. The amp frame is fixed by the 108, 780 or 1250 digit group and the control voltage by the trailing letter, so a 24 V control variant will not substitute for a 100…240 V unit even at the same current.

  • Amp frame settles the power section: 108 A, 780 A or 1250 A, with 75 HP, 600 HP and 1000 HP recorded at 460 V AC.
  • Control voltage settles the wiring to the existing control circuit: 100…240 V AC, 24 V AC/DC, 230/240 V AC or 110/120 V AC depending on frame.
  • Enclosure settles the mechanical fit: IP65 (Type 4/12) enclosed versus open construction.
  • Factory option strings must be quoted in full, as in 150-F108FBD-3-6P-HC3.

Frequently asked questions

What does SMC-Flex mean in a 150-F catalog number?

SMC-Flex is the Allen-Bradley solid-state motor controller family behind the 150-F prefix, used for reduced-voltage starting of three-phase motors. All 20 catalog numbers on this page carry that prefix, across three amp frames: 108 A, 780 A and 1250 A. The frame fixes the power rating, from 75 HP at 460 V AC on the 108 A units up to 1000 HP on the 1250 A units.

What is the difference between 150-F108NBD and 150-F108NBR?

Both are 108 A, 200…460 V AC, open construction and rated 75 HP at 460 V AC. The difference is the control supply: 150-F108NBD takes 100…240 V AC control, while 150-F108NBR takes 24 V AC at 50/60 Hz or 24 V DC. The power section and mounting are identical, so the existing control circuit decides which one is correct.

What is the difference between the F-series and N-series SMC-Flex units?

F-series numbers such as 150-F108FBD are enclosed in IP65 (Type 4/12) and can be mounted without a separate cabinet. N-series numbers such as 150-F108NBD are open construction for mounting inside existing switchgear. On the 108 A frame the four F-series models are 150-F108FAD, 150-F108FBD, 150-F108FCD and 150-F108FHD, and the seven open models include 150-F108NBD and 150-F108NZD.

Which 150-F model is rated 1250 A and 1000 HP?

Six catalog numbers carry that rating: 150-F1250NBA and 150-F1250NBAB at 200…460 V AC with 230/240 V AC control, 150-F1250NBE at 200…460 V AC with 110/120 V AC control, 150-F1250NCA at 200…575 V AC with 230/240 V AC control, and 150-F1250NCE at 200…575 V AC with 110/120 V AC control. All are open construction. 150-F1250NBED is also listed but has no spec table on the site.

Which control voltage do the 1250 A SMC-Flex units use?

Two options are recorded: 230/240 V AC on 150-F1250NBA, 150-F1250NBAB and 150-F1250NCA, and 110/120 V AC on 150-F1250NBE and 150-F1250NCE. That differs from the 108 A frame, where the choice is 100…240 V AC or 24 V AC/DC. Do not carry a control-voltage assumption across frames: the same letter position does not mean the same voltage on a 1250 A unit.

Are 150-F108FAD and 150-F108FBD different products?

Yes. Both are 108 A, IP65 (Type 4/12), 100…240 V AC control, but 150-F108FAD is the 230 V AC line-voltage class and 150-F108FBD is the 400…460 V AC class. The 500…575 V class is 150-F108FCD and the 200…208 V class is 150-F108FHD. Four separate catalog numbers cover the same current and enclosure on four different supplies.

Which lug kit should I order for a 150-F controller?

Two kits are listed. 100-DL860 takes #2/0 through 500 MCM cable and ships as four tin-plated copper lugs rated 600 V with UL 94 V-0 insulation and three heat-shrink sleeves. 100-DL630 is the IP20 / NEMA 1 terminal lug kit recorded for 0 °C to 40 °C ambient. The conductor size in the existing installation decides between them, and either kit is a separate catalog number from the starter.

Is a 690 V SMC-Flex listed on this site?

Yes, one: 150-F108NZD, rated 108 A with a 230…690 V AC three-phase line-voltage range and 100…240 V AC control in open construction. It is the widest line-voltage band recorded on any 108 A model here. The 500…575 V class is covered separately by 150-F108FCD (enclosed) and 150-F108NCD (open).

What information do you need to quote a 150-F replacement?

Send the full catalog number including any factory option string, a photo of the nameplate, the control circuit voltage and the conductor size at the terminals. The catalog number settles the amp frame and line voltage, the trailing letter settles control voltage, and the conductor size settles whether a lug kit is needed. Without the full number, the control voltage is the field most often quoted incorrectly.

Sources for the ratings in this guide

Every figure above is taken from the linked product page or brand page on this site. No value has been sourced from an external datasheet for a model this catalogue does not list.