PowerFlex 400 (22C) Selection Guide: Catalog Codes, Ratings and Enclosures

A PowerFlex 400 purchase is rarely a question about the family. It is a question about which of the 20 catalog numbers in this catalogue matches the nameplate already in the panel, and whether the enclosure on that number will fit the space left behind by the failed drive.

This guide works entirely from the spec tables stored on this site. Every rating below is taken from the linked product page for that catalog number; nothing is carried across from a neighbouring model or from a generic datasheet. Where a record is incomplete, the gap is stated rather than filled.

How do you read a 22C PowerFlex 400 catalog number?

Every 22C catalog number in this catalogue resolves the same way: 22C fixes the PowerFlex 400 family, the fourth character sets the voltage class, the next three digits track continuous output current, the eighth character fixes mounting and enclosure, and the 103 tail is identical on all 19 rated models.

  • The 22C prefix identifies the PowerFlex 400 family; all 20 catalog numbers listed here carry it.
  • B is the 200…240 V AC three-phase class and D is the 380…480 V AC three-phase class.
  • Digits five to seven track continuous output current: 012 for 22C-B012N103 (12 A), 088 for 22C-D088A103 (88 A), 145 for 22C-B145A103 (145 A).
  • The eighth character fixes mounting: N is IP20 open, F is IP20 flange mount, H is IP20 heatsinkless plate mount, and A is IP30 / NEMA 1 in frame D or E only.
  • The 103 tail is identical on all 19 rated models and the product pages do not document what it encodes, so no specification should be read into it.

Which 22C models does this catalogue list, and what are their ratings?

The catalogue carries 20 distinct 22C catalog numbers: ten in the 200…240 V AC class running from 2.2 kW (3 HP) at 12 A to 37 kW (50 HP) at 145 A, and ten in the 380…480 V AC class running from 4.0 kW (5 HP) at 10.5 A to 45 kW (60 HP) at 88 A.

  • 200…240 V AC: 22C-B012N103 is the smallest at 2.2 kW (3 HP) / 12 A and 22C-B145A103 the largest at 37 kW (50 HP) / 145 A.
  • 380…480 V AC: 22C-D010F103 is the smallest at 4.0 kW (5 HP) / 10.5 A and 22C-D088A103 the largest at 45 kW (60 HP) / 88 A.
  • 22C-B012F103 is listed on the site but its spec table is empty, so no rating is quoted for it here — read the nameplate before ordering.
  • Each catalog number below links to the single product page used as the reference for this guide.
Catalog numberPowerOutput currentVoltage classFrameEnclosure
22C-B012N1032.2 kW (3 HP)12 A200…240V AC, 3-phaseCIP20/NEMA/UL Type Open
22C-B017F1033.7 kW (5 HP)17.5 A200…240V AC, 3-phaseCIP20/NEMA UL Type Open flange mount
22C-B017H1033.7 kW (5 HP)17.5 A200…240V AC, 3-phase—IP20/NEMA UL Type Open, heatsinkless plate mount
22C-B024H1035.5 kW (7.5 HP)24 A200…240V AC, 3-phase—IP20 heatsinkless plate mount
22C-B033F1037.5 kW (10 HP)33 A200…240V AC, 3-phase, ±10 %—IP20/NEMA/UL Type Open flange mount
22C-B033H1037.5 kW (10 HP)33 A200…240V AC, 3-phase—IP20/NEMA UL Type Open, plate mount
22C-B033N1037.5 kW (10 HP)33 A200…240V AC, 3-phaseCIP20/NEMA/UL Type Open
22C-B065A10315.0 kW (20 HP)65 A200…240V AC, 3-phaseDIP30/NEMA 1/UL Type 1
22C-B145A10337.0 kW (50 HP)145 A200…240V AC, 3-phaseEIP30/NEMA 1/UL Type 1
22C-D010F1034.0 kW (5 HP)10.5 A380…480V AC, 3-phaseCIP20/NEMA/UL Type Open flange mount
22C-D017F1037.5 kW (10 HP)17 A380…480V AC, 3-phase, ±10 %—IP20/NEMA/UL Type Open, flange mount
22C-D017N1037.5 kW (10 HP)17 A380…480V AC, 3-phaseCIP20/NEMA/UL Type Open
22C-D022H10311.0 kW (15 HP)22 A380…480V AC, 3-phase—IP20 heatsinkless plate mount
22C-D030F10315.0 kW (20 HP)30 A380…480V AC, 3-phaseCIP20/NEMA UL Type Open flange mount
22C-D030N10315.0 kW (20 HP)30 A380…480V AC, 3-phaseCIP20/NEMA/UL Type Open
22C-D045A10322.0 kW (30 HP)45.5 A380…480V AC, 3-phaseDIP30/NEMA 1/UL Type 1
22C-D060A10330.0 kW (40 HP)60 A380…480V AC, 3-phase, ±10 %DIP30/NEMA 1/UL Type 1
22C-D072A10337.0 kW (50 HP)72 A380…480V AC, 3-phaseEIP30/NEMA 1/UL Type 1
22C-D088A10345.0 kW (60 HP)88 A380…480V AC, 3-phaseEIP30/NEMA 1/UL Type 1

Where a cell is blank, the product page does not record that field. Blank cells have not been filled from a sister model.

What do the PowerFlex 400 drives in this catalogue share?

The 19 rated models all list a programmable output frequency range of 0…320 Hz. Where a full spec table is present, the pages also record 97.5 % efficiency at rated amps, 48…63 Hz input frequency, sinusoidal PWM volts-per-hertz control, and an RS-485 DSI port carrying Modbus RTU, Metasys N2 and P1-FLN.

  • 0…320 Hz appears on 19 of the 20 catalog numbers; the exception is 22C-B012F103, whose spec table is empty.
  • 22C-D088A103 records 97.5 % efficiency at rated amps and a 0…460 V three-phase output for the 380…480 V class.
  • RS-485 DSI with Modbus RTU, Metasys N2 and P1-FLN is the built-in port on the drive pages that carry a communication field; 22C-D088A103 is one of them.
  • Fieldbus adapters are optional rather than built in: 22C-D088A103 lists 22-COMM adapters for BACnet, DeviceNet, EtherNet/IP, PROFIBUS DP, ControlNet and LonWorks.

How do the open, flange-mount, plate-mount and NEMA 1 versions differ?

The eighth character decides where the drive can physically sit: N is an IP20 open chassis for an existing enclosure, F is an IP20 flange mount for through-panel heat sinking, H is an IP20 heatsinkless plate mount, and A is a freestanding IP30 / NEMA 1 unit offered only in frames D and E.

  • N, IP20 / NEMA UL Type Open: 22C-B012N103, 22C-B033N103, 22C-D017N103, 22C-D030N103.
  • F, IP20 flange mount: 22C-B017F103, 22C-B033F103, 22C-D010F103, 22C-D017F103, 22C-D030F103.
  • H, IP20 heatsinkless plate mount: 22C-B017H103, 22C-B024H103, 22C-B033H103, 22C-D022H103.
  • A, IP30 / NEMA 1 / UL Type 1 in frame D or E: 22C-B065A103, 22C-B145A103, 22C-D045A103, 22C-D060A103, 22C-D072A103, 22C-D088A103.
  • Frame E is recorded only with the IP30 / NEMA 1 enclosure, on 22C-B145A103, 22C-D072A103 and 22C-D088A103.

Can a 15 kW 200…240 V drive replace a 15 kW 380…480 V drive?

No. The 22C-B065A103 delivers 15 kW (20 HP) at 65 A from 200…240 V AC three-phase input, while the 22C-D030N103 delivers the same 15 kW (20 HP) at 30 A from 380…480 V AC input. Equal power, but a different voltage class, a different current, and different cable and protection sizing.

  • 22C-B065A103: 15.0 kW (20 HP), 65 A, frame D, IP30 / NEMA 1 / UL Type 1.
  • 22C-D030N103: 15.0 kW (20 HP), 30 A, frame C, IP20 / NEMA UL Type Open.
  • The fourth character has to match the supply at the panel, not the motor nameplate.

Why do some 22C models appear on two product pages?

Nineteen of the twenty 22C catalog numbers are currently published twice, on two product URLs built from the same record, so both copies show the same ratings. This guide links one URL per catalog number, always the copy whose spec table is more complete.

  • 22C-D088A103 is listed at /products/22c-d088a103-allen-bradley-45-kw-88-a-powerflex-400-drive/ and at /products/22c-d088a103-allen-bradley-powerflex-400-45-kw-ac-drive/.
  • 22C-B033F103 is listed at /products/22c-b033f103-allen-bradley-powerflex-400-75-kw-drive/ and at /products/22c-b033f103-allen-bradley-powerflex-400-75-kw-ac-drive/.
  • Where the two copies disagree on completeness, the table above points to the fuller record — for example 22C-B017H103 resolves to the copy that carries a full spec table.
  • Order against the catalog number, not against the URL, so the duplicate listing does not matter at quotation.

How do you verify a 22C replacement before ordering?

Match four nameplate fields before ordering: catalog number, voltage class, continuous output current and enclosure. Then compare them with the spec table on the linked product page, because frame size, weight and panel cut-out differ between the open, flange, plate and NEMA 1 versions of the same rating.

  • Catalog number plus voltage class settles the family and the supply; current then confirms the rating code.
  • Enclosure and frame settle the mechanical fit: the same 15 kW rating is frame C open (22C-D030N103) and frame D NEMA 1 (22C-D060A103 lists 30 kW, so compare within the same rating code).
  • Send a nameplate photo with the enquiry when the printed catalog number is worn; the 103 tail is not a rating and cannot be used to recover a missing digit.

Frequently asked questions

What is the difference between 22C-B and 22C-D PowerFlex 400 drives?

The fourth character is the voltage class. B models take 200…240 V AC three-phase input and D models take 380…480 V AC three-phase input. The same mechanical power therefore needs roughly half the current on a D model: 22C-B065A103 is 15 kW (20 HP) at 65 A, while 22C-D030N103 is 15 kW (20 HP) at 30 A. Both are PowerFlex 400 fan-and-pump drives with a 0…320 Hz programmable output range.

Which 22C model is the largest in this catalogue?

22C-D088A103 is the largest 380…480 V AC model, rated 45 kW (60 HP) at 88 A in an IP30 / NEMA 1 / UL Type 1 frame E enclosure. The largest 200…240 V AC model is 22C-B145A103 at 37 kW (50 HP) and 145 A, also frame E and IP30 / NEMA 1. Nothing larger than these two is listed on the site, so a higher rating has to be sourced as a different catalog number.

What does the eighth character in 22C-B033N103 mean?

The N fixes the mounting and enclosure: IP20 / NEMA UL Type Open, with a frame C heatsink assembly. The same rating is also listed as F for an IP20 flange mount (22C-B033F103) and H for an IP20 heatsinkless plate mount (22C-B033H103). All three are 7.5 kW (10 HP) at 33 A on 200…240 V AC three-phase input, so the enclosure, not the rating, is what changes.

Are all PowerFlex 400 drives in this catalogue IP30?

No. Only the A-suffix units are IP30 / NEMA 1 / UL Type 1, and only in frames D and E: 22C-B065A103, 22C-B145A103, 22C-D045A103, 22C-D060A103, 22C-D072A103 and 22C-D088A103. The N, F and H suffixes are all IP20 variants intended to sit inside a cabinet, whether open, flange mounted or on a heatsinkless plate. Check the enclosure column in the table before assuming a NEMA 1 rating.

Can I fit a 22C-D030N103 where a 22C-B065A103 was installed?

No. Both are 15 kW (20 HP), but 22C-B065A103 expects 200…240 V AC three-phase input at 65 A, while 22C-D030N103 expects 380…480 V AC three-phase input at 30 A. Connecting a 380…480 V model to a 240 V supply leaves it outside its input range, and the reverse puts the drive and its protection outside their ratings. The voltage class has to match the supply at the panel.

What output frequency range do these drives support?

The product pages record 0…320 Hz programmable output frequency on 19 of the 20 catalog numbers. The exception is 22C-B012F103, whose spec table is empty on the site, so no frequency range is quoted for that model here. Input frequency is recorded as 48…63 Hz where the field is present, for example on the 380…480 V models that carry a complete spec table.

Which 22C models are frame E?

Three: 22C-B145A103 at 37 kW (50 HP) / 145 A, 22C-D072A103 at 37 kW (50 HP) / 72 A, and 22C-D088A103 at 45 kW (60 HP) / 88 A. All three are IP30 / NEMA 1 / UL Type 1. Frame E is the largest frame recorded in this catalogue, and the product pages record the enclosure as fixed for that frame rather than offered as an option.

Why is there no rating for 22C-B012F103?

The product record for 22C-B012F103 carries no specification table, so any power, current or enclosure value would have to be guessed from a neighbouring model. This guide does not do that. The unit is still listed and linked, and its model number follows the same B-class pattern, but the rating has to be read from the nameplate before a replacement is quoted.

Do these PowerFlex 400 drives include a fieldbus card?

A built-in RS-485 DSI port carrying Modbus RTU, Metasys N2 and P1-FLN is recorded on the drive pages that list a communication field, and 22C-D088A103 is one of them. EtherNet/IP, DeviceNet, BACnet, PROFIBUS DP, ControlNet and LonWorks are listed as optional 22-COMM adapters rather than built in. Confirm which adapter is fitted before replacing a networked drive.

What information do you need to quote a 22C replacement?

Send the full catalog number from the nameplate, the supply voltage at the panel, the motor nameplate current and a photo of the existing enclosure. The catalog number fixes voltage class, rating and enclosure in one string, so a clear photo usually settles the order. If the printed number is damaged, the supply voltage and motor current narrow the choice but do not replace the catalog number.

Sources for the ratings in this guide

Every figure above is taken from the linked product page or brand page on this site. No value has been sourced from an external datasheet for a model this catalogue does not list.

Leave a comment

Your email address will not be published. Required fields are marked *

Need a part? Ask us.

We reply within one business day.