Keyence Vibration Monitoring IV Series
Keyence IV-H150MA
Vibration Monitoring
Integrated vision sensor camera, short range, monochrome type.
- New Surplus
- Available on request
Availability & pricing
| Condition | Price | Stock / lead time | Action |
|---|---|---|---|
| New Surplus | On request | Available on request |
Ships within 7 business days
Technical specifications
| Model | IV-H150MA |
|---|---|
| Brand | Keyence |
| Series | IV Series |
| Type | Sensor, Short range |
| Installed distance | 50 to 150 mm |
| View | Installed distance 50 mm: 12 (H) x 9 (V) mm to installed distance 150 mm: 36 (H) x 27 (V) mm |
| Image sensor | 1/3 inch monochrome CMOS, 752 (H) x 480 (V) pixels |
| Focus adjustment | Auto |
| Exposure time | 1/20 to 1/25,000 |
| Illumination | Red LED |
| Lighting method | Pulse/DC lighting switchable |
| Tools | Shape Detection, Color Area, Area, Edge Pixels, Width/Height, Diameter, Edge Presence, Pitch, Position Adjustment, High Speed Position Adjustment |
| Number of tools | Detection tools: 16, position adjustment tool: 1 |
| Switch settings (programs) | 32 programs |
| Built-in ports | M12 4-pin connector (100BASE-TX/10BASE-T) |
| Protocols | FTP client, EtherNet/IP, PROFINET |
| Communication expansion | None |
| Supply voltage | 24 VDC +/-10% (including ripple) |
| Power consumption | 0.6 A or less |
| Output type | Open collector output, NPN/PNP switchable, N.O./N.C. switchable, maximum rating 26.4 V 50 mA |
| Number of inputs | 6 (IN1 to IN6) |
| Number of outputs | 4 (OUT1 to OUT4) |
| Operating temperature | 0 to +50°C (no freezing) |
| Relative humidity | 35 to 85% RH (no condensation) |
| Protection rating | IP67 (except when polarized filter attachment OP-87436/OP-87437 is mounted) |
| Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of X/Y/Z directions (except when dome attachment IV-D10 is mounted) |
| Shock resistance | 500 m/s^2, 3 times in each of 6 directions (except when dome attachment IV-D10 is mounted) |
| Dimensions (H×W×D) | Not available |
| Material | Main unit case: Aluminium die-casting. Packing: NBR. Front cover: Acrylic. Mounting adapter: POM. |
| Weight | Approx. 270 g |
Description
The IV-H150MA is a catalog part supplied for replacement and new-build use in industrial control installations. Every rating below is taken from the manufacturer documentation for this part number. Headline figures: supply voltage 24 VDC +/-10% (including ripple); weight Approx. 270 g; operating temperature 0 to +50°C (no freezing)
Electrical Ratings
Supply voltage is 24 VDC +/-10% (including ripple). match this against the supply available at the installation site, including any tolerance on the incoming feed. Power consumption is 0.6 A or less. size the power supply and the rack load around this figure; it is the draw the part places on the supply it is installed in. Output type is Open collector output, NPN/PNP switchable, N.O./N.C. switchable, maximum rating 26.4 V 50 mA. this defines what the part reads or drives; confirm it matches the transducer or signal source wired to it. Number of outputs is 4 (OUT1 to OUT4). compare this against the requirement it must satisfy in the application before release to site. Vibration resistance is 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of X/Y/Z directions (except when dome attachment IV-D10 is mounted). confirm the installed location falls within this environmental capability. Shock resistance is 500 m/s^2, 3 times in each of 6 directions (except when dome attachment IV-D10 is mounted). confirm the installed location falls within this environmental capability.
Mechanical & Dimensional Data
Weight is Approx. 270 g. factor this into lifting, rail-loading and shipping decisions; it is also the figure to quote when a handling study is required.
Environmental & Compliance Ratings
Operating temperature is 0 to +50°C (no freezing). check the enclosure temperature at the planned mounting location stays inside this band during the hottest operating period. Relative humidity is 35 to 85% RH (no condensation). maintain the stated humidity range in the cabinet; condensation is the usual cause of failure in equipment installed in humid plant rooms.
Signal & Communication
Protocols is FTP client, EtherNet/IP, PROFINET. match this to the controller or host configuration on site, including addressing and termination.
Additional Verified Data
Type is Sensor, Short range. Installed distance is 50 to 150 mm. View is Installed distance 50 mm: 12 (H) x 9 (V) mm to installed distance 150 mm: 36 (H) x 27 (V) mm. Image sensor is 1/3 inch monochrome CMOS, 752 (H) x 480 (V) pixels. Focus adjustment is Auto. Exposure time is 1/20 to 1/25,000. Illumination is Red LED. Lighting method is Pulse/DC lighting switchable. Number of tools is Detection tools: 16, position adjustment tool: 1. Switch settings (programs) is 32 programs. Built-in ports is M12 4-pin connector (100BASE-TX/10BASE-T). Number of inputs is 6 (IN1 to IN6). Protection rating is IP67 (except when polarized filter attachment OP-87436/OP-87437 is mounted).
Models in This Series
Autronexa currently lists this product entry as the only model in its entry. Cross-reference requests for equivalent or superseded part numbers are handled on request.
Confirming the Correct Variant Before Ordering
Read the part number marked on the unit being replaced and compare it character by character with the ordering code above, including any option suffix. Check the values in the technical specification table of this page against the nameplate on the existing unit rather than against a previous purchase record. Confirm the supply voltage available at the installation site is 24 VDC +/-10% (including ripple), which is the documented requirement for this model.
Request a Quote
Autronexa supplies the IV-H150MA as a quote-based item. Send the part number, quantity and destination for current stock, lead time and pricing; no fixed price is published for this part.
Frequently asked questions
What is the IV-H150MA?
Keyence IV-H150MA is an industrial automation component we supply from surplus and refurbished stock. Confirm the exact configuration, condition and lead time with our team before purchase.
Is the IV-H150MA in stock, and what is the lead time?
We list the IV-H150MA as in stock in New Surplus condition. Request a quote for current availability, pricing and confirmed lead time — most items ship within 1–3 business days.
Do you provide a datasheet for the IV-H150MA?
Where available, the product page links the original manufacturer datasheet (PDF). Use the request-a-quote form to receive the full documentation pack and compliance information.
Can the IV-H150MA be cross-referenced to an equivalent?
Many automation parts have equivalents or legacy replacements. Send us the IV-H150MA together with your application details and we will confirm compatibility and alternatives.
What input voltage does the IV-H150MA use?
The IV-H150MA operates at 24 VDC +/-10% (including ripple). Verify the exact range and any hazardous-area limits against the product label before installation, because input requirements vary by ordered variant.
What is the operating temperature range of the IV-H150MA?
The IV-H150MA operating temperature is listed as 0 to +50°C (no freezing). Stay within the documented band during operation; storage limits may differ. Elevated ambient conditions can reduce the continuous current or power rating of the module.
What are the dimensions and weight of the IV-H150MA?
The IV-H150MA measures Not available and weighs Approx. 270 g. Confirm clearance and rack or panel space before ordering.
What is the IV-H150MA and what is it used for?
The IV-H150MA is a industrial component device. It is used in industrial control and automation systems where a verified part number and specification match are required for replacement or new design.
What supply voltage does the IV-H150MA need?
The manufacturer documentation lists supply voltage 24 VDC +/-10% (including ripple). for this model. Confirm the supply at the installation site matches, including any tolerance on the incoming feed, before the part is ordered.
How much does the IV-H150MA weigh?
The documented weight is Approx. 270 g.. Use it for lifting, rail-loading and shipping decisions, and quote it when a handling study is required for the installation.
Related & compatible parts
Keyence
AP-34KP
Genuine surplus Keyence AP-34KP compound pressure sensor — verified condition, PNP dual output, faster than OEM lead times.
Keyence
GL-R16L
Genuine surplus Keyence GL-R16L Type 4 safety light curtain set — 16 beams, 600 mm detection height, verified…
Keyence
AP-34K
Genuine surplus Keyence AP-34K compound pressure sensor — verified condition, tested against OEM specs, ready to ship.
Keyence
EH-305S
Genuine surplus Keyence EH-305S sensor head — shielded ø5.4 cylindrical, 3 mm max detecting distance, IP67. Verified condition,…
News & guides for Keyence
Keyence spare parts: buying guide, series overview and how to order
Keyence spare parts buying guide: 5 parts online, popular series, condition options and how our RFQ process works.
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…
