Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up

Digital twin model of an industrial plant used for product carbon footprint data

TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle carbon footprint” in kg CO2e per commercial reference, split into manufacturing, use and end-of-life phases, alongside Product Environmental Profiles (PEPs) that are externally verified ISO 14025 Type III declarations. Separately, more than 50,000 Schneider MEP products have EPD data on the One Click LCA platform. Those are “Project EPDs” — internally verified variations of third-party verified base declarations — which matters when the number has to survive a tender review. LC-Analytics, Schneider’s AI and Makersite-based engine, generates this data internally; it is not a customer-facing lookup tool. The practical rule is to match the channel to the decision and check the verification label before quoting a figure.

What carbon data does Schneider Electric publish for an individual product?

Schneider Electric publishes two customer-facing layers of product carbon data: an attribute-level total life cycle carbon footprint in kg CO2e per commercial reference, and a Product Environmental Profile (PEP) document for the product range. The first is a single figure with a life-cycle split; the second is a full life-cycle assessment summary with a registration number and a validation date. Both sit under the company’s Environmental Data Program, which replaced and extended the older Green Premium data set.

According to Schneider’s Environmental Data Program page, the program covers more than 120,000 commercial references, and at least 14 attributes were available online by the end of 2025, representing 80% of product turnover. The underlying attribute set has grown from 5 to 30, covering carbon footprint, recycled material content, energy efficiency and end-of-life recycling information.

The distinction between “120,000 references with data” and “120,000 products with an EPD” is where most secondary summaries go wrong. The 120,000 figure describes references that carry at least some environmental attributes. It is not a count of published, third-party verified declarations. The number of externally verified PEPs is smaller, and the 50,000-plus MEP declarations discussed below live on a different platform with a different verification basis.

Where can you look up carbon data for a specific Schneider part number?

Start on the product page for the exact commercial reference on se.com. The “Environmental Data” or Green Premium section of that page carries the carbon footprint attributes and links to the PEP download. The same data is reachable through the mySchneider app, which Schneider’s product documentation lists as an official access route. For whole-building or MEP-level work, the second place to check is One Click LCA’s Materials Compass, where Schneider’s MEP EPD data is published.

In practice the lookup works like this:

  • Get the exact reference first. A family name is not enough. A reference such as the Modicon M221 24 V DC controller resolves to one product page with its own documents, while a generic “M221” search returns range-level material.
  • Read the attribute before the PDF. The carbon footprint attribute gives you a single kg CO2e figure per reference with a manufacturing, use and end-of-life split. It is enough for screening and for ranking alternatives.
  • Open the PEP when you need traceability. PEP documents carry a registration number (the format looks like SCHN-00896-V01.01-EN), a validation date and the program rules used. That is the document a consultant or a procurement auditor will ask for.
  • Check whether the declaration is range-level. PEPs are built on a representative product for the range. If your reference is a variant, the declaration may not describe your exact configuration.
  • Use One Click LCA for building-level work. If the question is “what is the embodied carbon of this switchboard inside my project”, the MEP EPD entry in One Click LCA is the relevant record, not the se.com product page.

One practical warning: the same reference can appear in several places with different numbers attached, because one figure may be a range average, another a specific-variant extrapolation, and a third an internally verified project declaration. Record which one you used, and from where, in your own project file.

What standards and system boundaries sit behind the numbers?

The total life cycle carbon footprint attribute is expressed in kg CO2e per commercial reference and covers the manufacturing (A), use (B) and end-of-life (C) phases. Schneider’s methodology guide states that the emission factors come from EIME version 5.9.1, database version 2016-11, in compliance with ISO 14044. PEPs follow a different route: they are quantitative Type III environmental declarations verified externally against ISO 14025, produced under the PEP ecopassport program or an equivalent program with a recognition agreement.

Two methodology details matter more than the headline standards list:

Extrapolation. Schneider’s guide states plainly that emissions for the carbon footprint attribute “may have been extrapolated for each specific product version.” That is normal for a portfolio of this size, but it means the figure for a low-volume variant is modelled rather than measured. If a number is going into a bid, ask whether it is a measured value, a range value or an extrapolation.

Verification level. The same guide defines four verification tiers: self-verification, internal non-expert verification, internal expert verification and third-party verification. The total life cycle carbon footprint attribute sits at internal expert verification, while an externally verified PEP sits at the third-party level. Both are legitimate; they are not interchangeable in a regulatory filing.

On standards, one clarification is worth repeating because it circulates widely. ISO 14067 appears in Schneider’s framework only in the context of the China Carbon Footprint certificate, alongside PAS 2050, PEP ecopassport and the China Product Carbon Footprint framework. It is not the general basis for the European PEP or for the carbon footprint attribute. The PEP ecopassport program itself states that PCR edition 4 integrates EN 50693 for electrical and electronic equipment, EN 15804 for construction products, the French RE2020 requirements and the European Commission’s Product Environmental Footprint work.

How do Schneider’s carbon data channels compare?

The table below maps what each channel actually is, so the right document is used for the right decision.

Channel What it contains Where it lives Verification basis Best used for
Environmental Data Program attribute Total life cycle carbon footprint in kg CO2e per reference, split into manufacturing, use and end of life, plus up to 30 environmental attributes se.com product pages, Green Premium section, mySchneider app Internal expert verification for the carbon attribute; third-party where an external label is claimed Fast screening, comparing two references, early specification
Product Environmental Profile (PEP) Full LCA summary for a representative product in a range, with life-cycle stage results and a registration number PEP ecopassport registry, linked from se.com product pages Externally verified Type III declaration under ISO 14025 Tenders, design documentation, RE2020 and EN 15804-based work
MEP EPD data on One Click LCA EPD records for more than 50,000 Schneider MEP products One Click LCA platform and Materials Compass Project EPDs: internally verified variations of third-party verified base EPDs, labelled “Internally Verified (ISO 14025)” Whole-building LCA, early design options, procurement benchmarking
LC-Analytics (Makersite) AI-generated product digital twins and automated LCA/EPD output across the portfolio Internal Schneider ecodesign workflow; not a public database Internal Product development and portfolio coverage, not customer lookup

How should procurement and maintenance teams use this data for replacement decisions?

Use the data to compare like with like, and treat the life-cycle split as the decision variable rather than the headline total. For a drive or a controller, the use phase usually dominates the total, so a replacement that changes efficiency changes the result far more than the embodied carbon of the part. For a passive component, the manufacturing phase carries proportionally more weight. In both cases, the comparison is only valid between references with the same functional unit, the same assumed service life and the same verification level.

A workable sequence for a spare-part or retrofit decision looks like this:

  • Identify the failed reference and the proposed replacement reference, for example an Altivar Process ATV930 75 kW drive replacing an older unit.
  • Pull the carbon footprint attribute for both, and note whether each figure is range-level or variant-specific.
  • Compare the use-phase and manufacturing-phase contributions separately, not just the total.
  • Check the PEP validation date. A declaration tied to an older database or an older product revision is not wrong, but it is stale for a decision made today.
  • Record the channel used — product page attribute, PEP or One Click LCA record — because the three are not directly comparable to each other.

For parts that are no longer in the current catalogue, the honest position is that carbon data may not exist for the exact reference. Legacy ranges are less likely to carry a current PEP than an active range such as the Altivar 320 IP65 7.5 kW drive. When no declaration exists, use the nearest documented range as a proxy, state the assumption in writing, and do not present the proxy as a product-specific figure. For discrete I/O and small modules, the same logic applies: a Modicon TM5 analog input module may be covered at range level rather than as an individual declaration.

The same caution applies to control-level components. A Zelio Logic Ethernet relay module and a Modicon Premium 16-point DC input module sit in very different positions in the catalogue lifecycle, and their documentation coverage reflects that. Checking coverage before promising a carbon figure to a customer is part of the job, not an afterthought.

What does Schneider’s carbon data not cover?

It does not cover every SKU at declaration level, it does not provide per-spare-part EPDs, and the largest MEP EPD set is not a third-party verified declaration for each individual product. The 50,000-plus MEP records on One Click LCA are Project EPDs: One Click LCA’s own explainer describes them as variations of existing third-party verified EPDs, internally verified and labelled “Internally Verified (ISO 14025)”, with both EPD numbers carried for traceability. They are not a substitute for third-party verified EPDs in certification schemes, regulatory filings or green public procurement that explicitly require external verification.

Three further limits are worth stating plainly:

  • Range-level declarations. A PEP describes a representative product. A variant with a different frame size, enclosure or option set may fall outside the declared configuration.
  • Platform exclusivity. The Schneider MEP EPD data set is published through One Click LCA, and the announcement describes it as exclusively available there. It is not a free download from the product page.
  • LC-Analytics is internal. Schneider’s September 2025 announcement describes LC-Analytics as an initiative that uses AI to generate digital twins for thousands of products and automate LCA and EPD creation; Makersite describes the scope as more than 200,000 SKUs. That is a production engine for Schneider’s own ecodesign work. It does not give an engineer a public lookup interface.

Why does MEP carbon data matter for panel builders and retrofit projects?

Because mechanical, electrical and plumbing equipment is a material share of embodied carbon, and it is the share that has historically been least documented. The One Click LCA announcement cites CIBSE research putting MEP at 15% to 50% of embodied carbon in commercial buildings, and up to 50% in retrofits over the building’s lifetime. For a panel builder or a maintenance engineer, that is the gap the Schneider data set is trying to close.

That context explains the shape of the data. A whole-building LCA needs a declaration per installed product, which is why 50,000-plus MEP records matter more than a handful of flagship PEPs. It also explains why the declarations are structured for building-level tools rather than for a maintenance spreadsheet: the output is designed to be consumed by LCA software that already knows how to apply EN 15804 modules and project quantities.

The practical consequence is that carbon data and commercial data live in different systems. Your ERP knows the reference, the price and the lead time. The environmental declaration lives on se.com or in One Click LCA, keyed to the same reference but maintained on its own cycle. Any process that needs both — a green tender response, a retrofit business case, a customer sustainability questionnaire — has to join the two deliberately.

Where do these facts come from?

Does every Schneider Electric product have an EPD?

No. More than 120,000 commercial references carry at least some environmental attributes under the Environmental Data Program, but that is not the same as an EPD per product. Externally verified PEPs are published at representative-product or range level, and the 50,000-plus MEP EPD records on One Click LCA are internally verified Project EPDs rather than individual third-party verified declarations.

Is Schneider’s EPD data on One Click LCA third-party verified?

Not in the strict sense. One Click LCA describes them as Project EPDs: non-published variations of existing third-party verified EPDs, internally verified and labelled “Internally Verified (ISO 14025)”. They carry both EPD numbers for traceability, but they should not be used where a certification scheme, regulatory filing or green public procurement process explicitly requires third-party verification.

Which standard is Schneider’s product carbon footprint based on?

The total life cycle carbon footprint attribute uses emission factors from EIME version 5.9.1, database version 2016-11, in compliance with ISO 14044. PEPs are Type III declarations verified under ISO 14025 through the PEP ecopassport program or an equivalent recognised program. ISO 14067 appears only in the context of the China Carbon Footprint certificate, together with PAS 2050 and the China Product Carbon Footprint framework.

Can this data be used in a whole-building LCA?

Yes, if you use the right record. The MEP EPD data on One Click LCA is intended for building-level assessment and is consumed through that platform. PEPs support European building work that references EN 15804 and RE2020. A single product-page carbon attribute is useful for screening, but it is not a substitute for a declaration in a formal whole-building submission.

Where do I find the PEP for a specific Schneider reference?

Open the product page for the exact commercial reference on se.com and use the Environmental Data or Green Premium section, which links to the PEP download. Schneider’s product documentation also lists the mySchneider app as an access route. Check the PEP registration number, the validation date and whether the declaration covers the range or your specific variant.

Leave a comment

Your email address will not be published. Required fields are marked *

Need a part? Ask us.

We reply within one business day.