Keyence AP-34K
Digital pressure sensor
Genuine surplus Keyence AP-34K compound pressure sensor — verified condition, tested against OEM specs, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Type | Compound pressure, NPN |
|---|---|
| Rated pressure | 29.9 to -29.9 inchHg |
| Detectable pressure range | -15 to +110 % of F.S. |
| Fluid type | Air or non-corrosive gases |
| Supply voltage | 12 to 24 VDC ±10% |
| Current consumption | 50 mA maximum (at 24 V), 90 mA maximum (at 12 V) |
| Output type | NPN open collector, 2-output (N.O./N.C. selectable) |
| Analog output | 1 to 5 V (Load impedance: 47 kΩ minimum) |
| Response time | 2.5 / 5 / 100 / 500 ms selectable |
| Operating temperature | 0 to +50 °C (No freezing) |
Description
When a pressure switch on a leak-test or vacuum-handling station starts drifting, the fastest fix is a verified replacement rather than a weeks-long OEM order. The Keyence AP-34K is a compound-pressure, NPN-output digital sensor from the AP-30 series, and Autronexa supplies it as genuine surplus or refurbished stock with condition checked before dispatch.
What the AP-30 Series Sensor Does on the Line
The AP-30 family covers gauge-pressure monitoring where operators need a readable number at the machine, not a remote signal. This unit reads 29.9 to -29.9 inchHg across a detectable range of -15 to +110 % of F.S., so it covers both positive pressure and vacuum in one device. A 3½-digit, two-color, 7-segment LED with 11 mm character height shows the value at a glance, and the display resolution of 0.1 inchHg, 0.2 kPa, 2 mmHg and 0.002 bar lets you match the readout to the unit your process sheet already uses. The two-color switching makes pass/fail states visible without reading the digits.

Electrical and Output Behaviour
The sensor runs on 12 to 24 VDC ±10%, drawing 50 mA maximum at 24 V and 90 mA maximum at 12 V. Two NPN open-collector outputs are selectable as N.O. or N.C., each rated 100 mA maximum at 40 V maximum with 1 V maximum residual voltage. An analog output of 1 to 5 V is available for a load impedance of 47 kΩ minimum, which suits chart recorders and simple monitoring inputs. Response time is selectable at 2.5, 5, 100 or 500 ms, so chattering prevention can be tuned to a noisy vacuum line without changing hardware. There are no built-in ports, protocols or communication expansion — this is a stand-alone sensor, and any network connection would need to be handled at the controller level.

Sourcing a Genuine Unit Without the OEM Wait
Because the AP-34K remains in active production, buyers sometimes assume the only safe route is a new order. Surplus and refurbished stock gives a practical alternative: units are tested against OEM datasheet specifications and functionally verified by our sourcing team, so the pressure range, output behaviour and display are confirmed before shipping. For maintenance teams holding a machine that is down, that means a genuine part with a clear lead time instead of an open-ended factory date. Autronexa also supports sourcing across Allen-Bradley, Bently Nevada, Siemens and Schneider lines, so a mixed bill of materials can be handled in one request. Before ordering, confirm the exact model and revision on the existing unit, decide whether surplus or refurbished condition fits the application, and check that the oil-proof cabtyre cable and pressure port thread match your installation. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Keyence AP-34K, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished components, not grey-market copies.
What condition will the AP-34K arrive in?
The site default condition is Refurbished: units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — confirm the condition you need when you request a quote.
How fast can you ship the AP-34K?
Lead time depends on current stock at the time of your request. Contact Autronexa for the current lead time and availability for this model.
Does the AP-34K connect to a PLC or network?
No. The unit has no built-in ports, protocols or communication expansion. It provides two NPN open-collector outputs and a 1 to 5 V analog output that can be wired to a controller's discrete or analog inputs.
Is the AP-34K still supported by Keyence?
Yes — official Keyence production status is confirmed as active (last verified 2026-09). Contact Autronexa if you need documentation or a current availability check.
Related & compatible parts
Keyence
AP-32KP
Genuine Keyence AP-32KP digital pressure sensor, surplus/refurbished, verified condition and clear lead times from Autronexa.
Keyence · PZ-G series
PZ-G41N
Built-in amplifier photoelectric sensor, diffuse reflective, long-range.
Keyence · LR-Z series
LR-ZB100CN
Self-contained CMOS laser photoelectric sensor, rectangular, NPN output, m8 connector, 4-pin.
Keyence
GL-R14L
Genuine surplus Keyence GL-R14L Type 4 light curtain set — 14 beams, 520 mm detection height, verified and…
News & guides for Keyence
Keyence spare parts: buying guide, series overview and how to order
Keyence spare parts buying guide: 5 parts online, popular series, condition options and how our RFQ process works.
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…