Keyence GL-R14L
Transmitter + Receiver set
Genuine surplus Keyence GL-R14L Type 4 light curtain set — 14 beams, 520 mm detection height, verified and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Beam axes | 14 |
|---|---|
| Beam axis spacing | 40 mm |
| Detection height | 520 mm |
| Total length | 560 mm |
| Detection capability | ø45 mm |
| Detecting distance | 0.2 to 15 m |
| Supply voltage | 24 VDC ±20%, Class 2 |
| Control output (OSSD) | 2 transistor outputs, max. load 500 mA |
| Protection rating | IP65/IP67 (IEC60529) |
| Operating temperature | -10 to +55 °C (No freezing) |
Description
When a press or packaging line needs a Type 4 light curtain, waiting weeks for a factory order stalls the whole cell. The Keyence GL-R14L transmitter and receiver set — 14 beam axes over a 520 mm detection height — is the kind of genuine surplus unit Autronexa stocks and verifies so maintenance teams can close the guard gap without an OEM lead-time penalty.
Why the GL-R Series Still Earns Its Place on the Line
Safety light curtains have moved from simple trip devices to fully monitored ESPE systems, and the GL-R family reflects that shift. This set pairs a transmitter and receiver with optical or wire synchronization, chosen by wiring, and an infrared LED source at 870 nm. The 14 beam axes sit at 40 mm spacing, giving a ø45 mm detection capability across a 520 mm detection height and 560 mm total length — a body-protection profile suited to guarding access points rather than finger-level hazards. Detection is straightforward: the OSSD turns ON when no interruption is present in the detection zone. Two GL-R systems can run side by side thanks to Channel A/B interference prevention on optical synchronization, or automatic handling on wire sync.

What the Electrical and Safety Ratings Mean in Practice
The set runs on 24 VDC ±20% with a Class 2 supply and draws at most 48 mA at the transmitter and 71 mA at the receiver with indicators on, OSSD current excluded. The two transistor OSSDs are PNP or NPN depending on cable type and carry up to 500 mA each, with reverse-current, per-output short-circuit and surge protection built in. The safety ratings are the reason buyers seek this model: IEC61496-1/-2 Type 4 ESPE/AOPD, IEC61508 SIL3, IEC62061 SIL CL3, and EN ISO13849-1 Category 4 PLe, alongside UL508 and UL1998. The housing is aluminum with nylon upper and lower cases and a polycarbonate and SUS304 front cover, rated IP65/IP67, and the set operates from -10 to +55 °C. Response time on the OSSD channel is max. 6.6 ms.

Genuine Surplus, Verified Before It Ships
Autronexa supplies this set as genuine surplus or professionally refurbished stock, tested against OEM datasheet specifications and functionally verified by our sourcing team. That matters on a safety device where a clone or mislabeled unit is worse than no spare at all. Keyence lists the GL-R14L as active, so the surplus channel is about availability and cost rather than discontinued support — and it keeps a verified spare within reach when an OEM order would leave a guard open. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Keyence GL-R14L set, or a copy?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and professionally refurbished components, not grey-market clones.
What condition will the GL-R14L arrive in?
Our default condition is Refurbished: the transmitter and receiver are tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade confirmed before purchase.
How fast can you ship the GL-R14L?
Lead time depends on current stock at the time of your request. Contact Autronexa with your part number for verified condition and current availability, and we will confirm the shipping date.
Does the GL-R14L work with our existing safety circuit?
The set provides two transistor OSSDs (PNP or NPN determined by cable type) rated up to 500 mA, with 24 VDC supply. Compatibility with your specific safety relay or controller should be confirmed against your circuit design before installation.
Is the GL-R14L still supported by Keyence?
Keyence lists this model as active, with production status confirmed via the official product page as of 2026-09. Please verify current lifecycle status and availability with Autronexa before ordering.
Related & compatible parts
Keyence
GL-R12L
Genuine surplus Keyence GL-R12L Type 4 safety light curtain set — 12 beam axes, 480 mm length, verified…
Keyence
GL-R10L
Genuine surplus Keyence GL-R10L Type 4 light curtain set, 10 beams, 400 mm, verified condition and ready to…
Keyence
AP-32K
Genuine surplus Keyence AP-32K digital pressure sensor — verified NPN two-output unit with 1–5 V analog output, ready…
Keyence
AP-31K
Genuine surplus Keyence AP-31K negative-pressure sensor, verified and ready to ship — a practical alternative to OEM lead…
News & guides for Keyence
Keyence spare parts: buying guide, series overview and how to order
Keyence spare parts buying guide: 5 parts online, popular series, condition options and how our RFQ process works.
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…