Keyence AP-31K
Digital pressure sensor
Genuine surplus Keyence AP-31K negative-pressure sensor, verified and ready to ship — a practical alternative to OEM lead times.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated pressure | 0 to -29.9 inchHg |
|---|---|
| Detectable pressure range | -15 to +110 % of F.S. |
| Fluid type | Air or non-corrosive gases |
| Supply voltage | 12 to 24 VDC ±10% |
| Output type | NPN open collector, 2-output (N.O./N.C. selectable) |
| Analog output | 1 to 5 V (Load impedance: 47 kΩ minimum) |
| Response time | 2.5 / 5 / 100 / 500 ms selectable |
| Operating temperature | 0 to +50 °C (No freezing) |
| Weight | Approx. 120 g |
Description
When a vacuum pick-and-place head starts missing parts, the pressure sensor is usually the first suspect — and the last part anyone wants to wait weeks for. The Keyence AP-31K is a negative-pressure, NPN-output digital sensor from the AP-30 series, and Autronexa supplies it as verified surplus for maintenance teams that need a genuine unit without an OEM lead-time queue.
What This Sensor Does on the Line
The AP-31K reads gauge pressure in the negative range, from 0 to -29.9 inchHg, with a detectable range of -15 to +110 % of full scale. That window covers the vacuum levels found in pick-and-place, chucking and leak-test stations, where a dropped vacuum signal stops the cycle. The 3½-digit, two-colour, 7-segment LED display (11 mm character height) switches colour to flag setpoint status at a glance, so an operator can confirm vacuum at the nozzle without a separate gauge. Resolution is 0.1 inchHg, 0.1 kPa, 1 mmHg or 0.001 bar, and response time is selectable at 2.5, 5, 100 or 500 ms, letting you trade speed for stability where chattering would otherwise trip the output.

Electrical and Output Details
The unit runs on 12 to 24 VDC ±10%, drawing 50 mA maximum at 24 V and 90 mA maximum at 12 V. Two NPN open-collector outputs are selectable as N.O. or N.C., rated 100 mA maximum at 40 V maximum with 1 V maximum residual voltage. A 1 to 5 V analog output is also provided for a load impedance of 47 kΩ minimum, which suits trend logging on a PLC analog card. There are no built-in communication ports and no expansion options, so integration is purely discrete and analog wiring. The pressure port is die-cast zinc, the front housing polyamide, and the cable is oil-proof cabtyre. Operating range is 0 to +50 °C at 35 to 85 % RH, non-condensing, with proof pressure of 72.5 PSI.

Why Buy This Model as Surplus
Keyence lists the AP-30 series as active, so the case for surplus is availability rather than obsolescence. A failed sensor on a running machine rarely waits for a standard factory order, and refurbished units give you a tested spare at a fraction of new-list cost. Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference, then functionally checks it before dispatch. Because This unit is a current model, matching the exact suffix and output type matters — confirm your existing unit’s label before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Keyence AP-31K, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished Keyence sensors, not grey-market copies.
What condition will the AP-31K arrive in?
Our default condition is refurbished: the unit is tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact us if you need a surplus-only unit instead.
How fast can you ship this sensor?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability, and we will confirm the ship date before you order.
Does the AP-31K support any fieldbus or communication protocol?
No. The datasheet lists no built-in ports, no protocols and no communication expansion. Integration is through the two NPN open-collector outputs and the 1 to 5 V analog output.
Is the AP-31K still in production at Keyence?
Yes — Keyence production status is confirmed as active (last verified 2026-09). Surplus stock is therefore an availability and cost option rather than an obsolescence workaround.
Related & compatible parts
Keyence
GL-R16L
Genuine surplus Keyence GL-R16L Type 4 safety light curtain set — 16 beams, 600 mm detection height, verified…
Keyence
GL-R08L
Genuine surplus Keyence GL-R08L Type 4 light curtain set — 8 beams, 280 mm detection height, verified condition…
Keyence
GL-R12L
Genuine surplus Keyence GL-R12L Type 4 safety light curtain set — 12 beam axes, 480 mm length, verified…
Keyence · IV Series
IV-H150MA
KEYENCE CORPORATION IV-H150MA Vibration Monitoring. Type: Sensor, Short range; Installed distance: 50 to 150 mm.
News & guides for Keyence
Keyence spare parts: buying guide, series overview and how to order
Keyence spare parts buying guide: 5 parts online, popular series, condition options and how our RFQ process works.
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…