Technical specifications

Analog Outputs 4 Outputs
Data Format Full 16 Bits Signed Format
Update Time 2 ms
Isolation (Channels to Ground) 500V AC for 1 Minute
Maximum Power Dissipation 8.5 Watts
Reverse Polarity Protection Internal, Supported
Operating Temperature 0 to 60 degrees Celsius
Storage Temperature -40 to 85 degrees Celsius
Maximum Humidity 95% (non-condensing), operating and storage
Approximate Dimensions 4.9 x 1.9 x 5.6 inches

Description

The Schneider Electric 170AAO92100 is a Modicon Momentum analog output base module with four outputs in full 16-bit signed format. Maintenance and automation teams choose genuine surplus or refurbished units when an OEM lead time would stall a running line — Autronexa verifies each module against OEM datasheet markings before it ships.

What This Momentum Module Does in a Control Cabinet

The 170AAO92100 carries four analog output channels and converts controller data into a full 16-bit signed format, so the signal resolution stays fine enough for setpoint and valve-position work rather than coarse on/off switching. A 2 ms update time keeps the output loop responsive in monitoring and control duties. Isolation between channels and ground is rated 500V AC for one minute, which matters where field wiring runs near drives or other noise sources. Internal reverse polarity protection guards the module against incorrect wiring during commissioning. The standard module format and approximate dimensions of 4.9 x 1.9 x 5.6 inches suit cabinet layouts already built around the Momentum family.

Figure 1: Front view of the Schneider Electric 170AAO92100 Analog output base module showing its physical design and enclosure.

Why Buy This Module as Genuine Surplus

A failed analog output module stops the loop it serves, and an OEM order can put weeks between fault and restart. Autronexa stocks surplus and refurbished Momentum units so a replacement is available without that wait. Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team; condition is stated before you commit, and lead time is confirmed at the time of quote. That combination — genuine parts, verified, with a clear ship date — is the practical alternative to paying full OEM list price for a module that may no longer be in regular production. For buyers comparing options, the trade-off is straightforward: new-from-OEM means longest lead time and highest price; grey-market units carry unknown history; verified surplus sits between them on cost with a documented condition check.

Figure 2: Technical layout and connection details for the Schneider Electric 170AAO92100 Analog output base module.

Sourcing Checklist Before You Order

Confirm the base module type matches the Momentum assembly you are repairing — this is an analog output base, not a processor or input base, and mixing them will not work. Check the part number against your existing module, including any suffix on the label, and note the revision if one is printed. Decide whether you need surplus or refurbished condition and ask for the grading in writing. Verify environmental fit: 0 to 60 degrees Celsius operating, -40 to 85 degrees Celsius storage, and 95% non-condensing humidity in both states. Maximum power dissipation is 8.5 watts, so confirm cabinet thermal headroom. The unit weighs 0.50 lbs (0.23 kg). Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: 170AAO92100-datasheet.pdf

Frequently asked questions

Is this a genuine Schneider Electric 170AAO92100, or a clone?

Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished modules, not copies.

What condition will the module arrive in?

Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — ask for the grading in writing before you order.

How fast can you ship the 170AAO92100?

Lead time depends on current stock at the time of your request. Contact Autronexa with your part number and we will confirm availability and a ship date.

Does this module fit a standard Modicon Momentum assembly?

Yes — it is an analog output base module in standard module format for the Momentum series, with four outputs in full 16-bit signed format and a 2 ms update time.

Is the 170AAO92100 still supported by Schneider Electric?

Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before ordering.

Related & compatible parts

Schneider Electric

ATV930C31N4C

Genuine surplus Schneider Electric ATV930C31N4C drive — 315 kW ND, IP00, verified condition, faster than OEM lead time.

In Stock

Schneider Electric

BMEP581020H

Genuine surplus BMEP581020H processor module for Modicon M580 — verified condition and fast lead times from Autronexa.

In Stock

Schneider Electric

140DAI75300C

Genuine surplus Schneider Electric 140DAI75300C: 32-channel 230 VAC discrete input module for Modicon Quantum, verified and ready to…

In Stock

Schneider Electric

ATV320U04N4C

Genuine surplus Schneider ATV320U04N4C Altivar drive, 0.37 kW, verified condition and ready to ship from Autronexa.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: 170AAO92100

We reply within one business day.

170AAO92100 Quote reply within 1 business day