Schneider Electric I/O & Function Modules
Schneider Electric 170ARM37030
Discrete relay I/O base AC
Genuine surplus Schneider Electric 170ARM37030 relay I/O base — 10 inputs, 8 outputs, 24–230 V AC. Verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Product Line | Modicon |
|---|---|
| Range of Product | Modicon Momentum automation platform |
| Discrete Input Number | 10 (IEC 1131-2 Type 1) |
| Discrete Output Number | 8 |
| Voltage Rating | 24–230 V AC |
| Input Voltage Limits | 3–30 V |
| Isolation Between Group of I/O Channels | 1780 V AC |
| Isolation Between Channels and Bus | 500 V AC |
| Power Dissipation | ≤ 8.5 W |
| Protective Treatment | TC |
Description
How do you keep a Modicon Momentum line running when a discrete relay I/O base fails and OEM lead times stretch? The Schneider Electric 170ARM37030 — a 10-input, 8-output relay base rated 24–230 V AC — is the kind of genuine surplus part Autronexa stocks and verifies so maintenance teams avoid long waits.
What This Modicon Momentum Base Does
The 170ARM37030 is a discrete relay I/O base for the Modicon Momentum automation platform. It carries ten discrete inputs compliant with IEC 1131-2 Type 1 and eight discrete outputs, giving one module enough points to handle mixed control tasks in a single slot. Positive input logic suits standard digital control schemes. The 24–230 V AC voltage rating lets the same base serve low-voltage control circuits and higher-voltage relay loads, which reduces the number of variants a plant must carry. Isolation between I/O channel groups reaches 1780 V AC, and isolation between channels and the bus is 500 V AC — practical protection when the module sits near contactors or other noisy loads. Power dissipation stays at or below 8.5 W, and the TC protective treatment supports operation in tougher panel environments.

Why Genuine Surplus Fits This Relay Base
Relay I/O bases are wear items: output contacts cycle, panels get rebuilt, and a failed base can idle an entire Momentum rack. Buying new from the OEM is one route, but lead time is often the deciding factor when production is down. Autronexa supplies genuine surplus and refurbished units, each tested against OEM datasheet specifications and functionally verified by our sourcing team before it ships. For this model that means confirming the 10-input/8-output configuration, the 24–230 V AC rating, and the isolation values match the datasheet — not a lookalike. You get a verified part with a clear lead time instead of an open-ended wait, and the cost profile of surplus rather than full OEM list price.

Sourcing Checklist Before You Order
Match the exact part number and confirm the Momentum platform variant your rack expects; This unit is a specific configuration, not a generic relay base. Decide whether you need surplus or refurbished condition and ask for the condition statement in writing. Check that your field wiring and input voltage limits (3–30 V) suit the sensors and actuators already installed. Because lifecycle status is not stated in our public data, please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 170ARM37030, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it is listed. The 170ARM37030 we ship is a genuine Schneider Electric Modicon Momentum discrete relay I/O base, not a copy.
What condition will the 170ARM37030 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — request the condition statement with your quote.
How fast can you ship the 170ARM37030?
Lead time depends on current stock. Contact Autronexa with your part number and we will confirm verified condition and current availability, including the expected ship date.
Does the 170ARM37030 suit both 24 V and 230 V AC circuits?
The datasheet voltage rating is 24–230 V AC, with input voltage limits of 3–30 V. Confirm your specific field wiring against those limits before ordering.
Is the 170ARM37030 still supported by Schneider Electric?
Lifecycle status is not stated in our public data. Contact Autronexa to verify OEM support status and current availability before you commit to a replacement plan.
Related & compatible parts
Schneider Electric
170BSM01600
Genuine surplus Schneider 170BSM01600 16-channel input simulator — verified, tested, and ready to ship from Autronexa.
Schneider Electric
ATV320U40N4WS
Genuine surplus Schneider ATV320U40N4WS 4 kW IP65 drive with disconnect and C2 EMC filter — verified condition, faster…
Schneider Electric
BMXP3420302
Genuine surplus Schneider Electric BMXP3420302 processor module for Modicon M340 — verified condition, practical lead times, engineering sourcing…
Schneider Electric
BMXNGD0100
Genuine surplus Schneider BMXNGD0100 Ethernet module for Modicon M580 — verified, tested, and ready to ship from Autronexa.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…