Schneider Electric Communication Modules
Schneider Electric 170ENT11001
Communication Adapter
Genuine surplus Schneider Electric 170ENT11001 Ethernet TCP/IP adapter for Modicon Momentum — verified condition, faster than OEM lead times.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Product Line | Modicon Momentum |
|---|---|
| Communication Protocol | Ethernet TCP/IP |
| Transmission Rate | 10/100 Mbit/s |
| Ethernet Port Type | 100BASE-TX, RJ45 connector |
| Access Method | Master/slave and peer-to-peer (P2P) |
| Network Topology | Star network and multidrop |
| Devices Per Segment | 0 to 32 |
| Max Cable Distance | 3,280 feet (1,000 meters) |
| Operating Temperature | 0 to 60°C, non-condensing |
| Protection Class | IP20 |
Description
When a Modicon Momentum node drops off the network, every minute of lost production counts. The 170ENT11001 is Schneider Electric’s Ethernet TCP/IP communication adapter for the Momentum platform, and sourcing a genuine surplus unit keeps your line running without waiting on OEM lead times. Autronexa supplies verified surplus and refurbished units with practical lead times.
What This Adapter Does on the Network
The adapter bridges Momentum I/O modules to an Ethernet TCP/IP network. It supports 10 or 100 Mbit/s transmission over shielded twisted pair cable through an RJ45 100BASE-TX port, with star or multidrop topology. The access method covers master/slave and peer-to-peer, and a segment can carry 0 to 32 devices. Maximum cable distance between devices reaches 3,280 feet (1,000 meters), which gives layout flexibility in larger cabinets and across plant floors. Four status LEDs (three green, one yellow) show operating state at a glance, and CRC-32 control protects data integrity. IP parameters are assigned via a BOOTP server or a user-assigned IP address, and the unit carries a unique IEEE global address.

Why Genuine Surplus Makes Sense Here
Network adapters are a common failure point in Momentum installations, and OEM lead times can stall a maintenance window. A verified surplus or refurbished adapter gets the segment back online faster. Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch. The IP20 rating and 0 to 60°C operating range suit standard control cabinets, while storage tolerance from -40 to 85°C covers warehouse conditions. For a maintenance engineer, the practical benefit is a known-good spare that matches the original part number and network parameters — no reconfiguration surprises, no clone risk.

Sourcing and Fit Checks
Before ordering, confirm the exact part number on the existing module and check the network topology and device count per segment against your design. Decide whether a surplus or refurbished unit fits your spares policy; both are tested and verified. Confirm cable type — shielded twisted pairs — and RJ45 port compatibility with your 100BASE-TX infrastructure. The adapter is compatible with the Modicon Momentum automation platform and supports Ethernet TCP/IP with BOOTP or user-assigned addressing. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 170ENT11001, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished units only.
What condition will the adapter arrive in?
Units are supplied refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade.
How fast can you ship the 170ENT11001?
Lead time depends on current stock. Contact Autronexa for verified availability and a practical ship date before committing to a maintenance window.
Does this adapter work with Modicon Momentum I/O modules?
Yes — it is the Ethernet TCP/IP communication adapter for the Modicon Momentum platform, supporting 10/100 Mbit/s over 100BASE-TX with star or multidrop topology.
Is the 170ENT11001 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Please verify current lifecycle status and availability with Autronexa before ordering.
Related & compatible parts
Schneider Electric
ATV310HU55N4S
Genuine surplus Schneider ATV310HU55N4S drive, 5.5 kW heavy duty, 380–460 V three-phase, Modbus RTU — verified condition and…
Schneider Electric
iC60N 2P C25
Genuine surplus Schneider Electric iC60N 2P C25 circuit breaker — verified 25A C-curve, 6 kA, DIN rail. Sourced…
Schneider Electric
TSXCANCBDD1
Genuine surplus Schneider Electric TSXCANCBDD1 CANopen cordset, 1 m, molded SUB-D9 connectors, IP20, UL — verified condition from…
Schneider Electric
ATV930C31N4F
Genuine surplus Schneider ATV930C31N4F floor-standing drive, 315 kW ND, verified condition and fast lead times from Autronexa.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…