Schneider Electric Communication Modules
Schneider Electric 170INT11001
Integral component within the Modicon Momentum series
Genuine surplus Schneider Electric 170INT11001 INTERBUS-S adapter for Modicon Momentum I/O — verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Communication Protocol | INTERBUS-S |
|---|---|
| Compatible Modules | Momentum I/O bases |
| Topology Support | Ring topology |
| Transmission Medium | Twisted pair cable |
| Data Transmission Rate | 500 kbps |
| Operating Temperature | 0°C to 55°C |
| Storage Temperature | -20°C to 60°C |
| Altitude | 2000 meters |
| Environment | No corrosive gases |
Description
The Schneider Electric 170INT11001 is a communication adapter for the Modicon Momentum series, built for maintenance and automation teams that need INTERBUS-S connectivity to Momentum I/O bases without waiting on OEM lead times. Autronexa supplies this unit as verified surplus and refurbished stock, tested against OEM datasheet specifications and functionally checked before dispatch.
What This Adapter Does in a Momentum System
The adapter sits between a Momentum I/O base and an INTERBUS-S network, translating field signals into ring-topology traffic over twisted pair cable. It transmits at 500 kbps, a rate that suits distributed I/O blocks where deterministic cycle time matters more than raw bandwidth. Because it supports ring topology, the network can be wired so that a single cable break does not take down the whole segment — a practical reliability feature for conveyor lines, packaging cells, and process skids where Momentum I/O is commonly deployed.

Operating Envelope and Installation Conditions
The unit is rated for 0°C to 55°C in operation and -20°C to 60°C in storage, so it tolerates unheated cabinets and non-climate-controlled warehouses alike. It is specified for altitudes up to 2000 meters and for environments free of corrosive gases. At roughly 0.45 kg (1 lb.), it mounts without special lifting equipment. Before commissioning, confirm cabinet airflow keeps ambient within the operating band and that no chlorine, sulfur, or ammonia sources sit nearby — both conditions are stated limits, not preferences.

Why Genuine Surplus Fits This Part
Momentum-series INTERBUS-S adapters are legacy-architecture components, and new-from-OEM availability for this generation is rarely fast. That makes verified surplus the practical route for a running line. Autronexa sources genuine units, cross-references part-number markings against OEM documentation, and functionally verifies each adapter before it ships. You get a tested component with a clear lead time instead of an open-ended factory order. For buyers comparing against grey-market sellers, the difference is traceability: every unit is checked, not just boxed.
Sourcing Checklist Before You Order
Confirm three things: the exact part number 170INT11001, that your network runs INTERBUS-S rather than another fieldbus, and that the mating Momentum I/O base matches your existing configuration. If you are replacing a failed adapter mid-shift, send us the base model and cabinet conditions and our sourcing team will confirm fit. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric 170INT11001, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished components, not grey-market copies.
What condition will the adapter arrive in?
Units ship in refurbished condition, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade confirmed before purchase.
How fast can you ship the 170INT11001?
Contact Autronexa for current lead time and stock status. Surplus and refurbished units typically move faster than a factory order for legacy Momentum components.
Does this adapter work with my existing Momentum I/O bases?
The unit is specified for use with Momentum I/O bases over INTERBUS-S at 500 kbps using twisted pair cable and ring topology. Confirm your base model and network protocol with our team before ordering.
Is the 170INT11001 still supported by Schneider Electric?
Lifecycle status is not stated in our current data. Contact Autronexa to verify OEM support status and availability before you commit to a replacement plan.
Related & compatible parts
Schneider Electric
BMXEHC0200
Genuine surplus Schneider BMXEHC0200 high-speed counter module — 2 channels, 60 kHz, verified and ready to ship from…
Schneider Electric
140NOE35100
Genuine surplus Schneider Electric 140NOE35100 Ethernet module — fiber-optic 10BASE-FL connectivity for Modicon Quantum, verified and ready to…
Schneider Electric
ATV71HD22N4
Genuine surplus Schneider ATV71HD22N4 22 kW drive, verified and tested. Phase-out model — secure tested stock with faster…
Schneider Electric
BMENOP0300
Genuine surplus Schneider Electric BMENOP0300 communication module for Modicon M580 PACs — verified condition, ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…