Siemens 3RW4436-6BC44
Soft starter
Genuine surplus Siemens 3RW4436-6BC44 soft starter, 90 kW at 400 V, 162 A standard, with inside-delta capability and verified condition.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated operating current at 40 °C (standard) | 162 A |
|---|---|
| Rated power at 400 V (standard) | 90 kW |
| Inside-delta circuit current at 40 °C | 281 A |
| Inside-delta circuit power at 400 V | 160 kW |
| Operating voltage (standard circuit) | 200 … 460 V AC |
| Control supply voltage | 230 V AC |
| Operating frequency | 50 … 60 Hz |
| Ambient temperature during operation | 60 °C |
| Protection class | IP00 |
| Dimensions (W × H × D) | 170 × 200 × 270 mm |
Description
When a soft starter fails on a critical three-phase motor, every hour of downtime adds cost and pressure. The Siemens 3RW4436-6BC44 is a SIRIUS soft starter rated 90 kW at 400 V in standard circuit, and sourcing a genuine surplus or refurbished unit through Autronexa gives maintenance teams a practical path to restore operation without waiting on OEM lead times.
What the 3RW4436-6BC44 Delivers on the Line
This soft starter handles standard switching at 162 A and 90 kW at 400 V, with an inside-delta circuit rating of 281 A and 160 kW. The integrated bridging contact system and thyristors reduce wear parts, while intrinsic device protection and motor overload protection simplify panel design. An external reset and adjustable current limitation let technicians tune starting behaviour to the driven load. For maintenance engineers, the screw-terminal main connections and busbar design make inspection and torque checks straightforward during planned shutdowns.

Why Genuine Surplus Fits This SIRIUS Model
Autronexa supplies genuine surplus and refurbished automation components, and each unit is verified against OEM datasheet markings before dispatch. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Because the SIRIUS soft starter family remains widely deployed, surplus stock often provides a faster route than factory order cycles. The practical benefit is clear: a verified unit with known lead time, not an open-ended wait. Contact Autronexa with your part number for verified condition and current availability.

Sourcing Checks Before You Install
Confirm the exact model and any revision suffix match your panel documentation. Verify the condition grade — surplus versus refurbished — and check that the 230 V AC control supply suits your control circuit. Review the ambient temperature rating of 60 °C during operation and the IP00 protection class, which requires installation inside a suitable enclosure. Finally, confirm terminal compatibility for your conductor cross-section. Autronexa provides technical sourcing help across Allen-Bradley, Bently Nevada, Siemens, Schneider and more.
Frequently asked questions
Is this a genuine Siemens 3RW4436-6BC44 or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before listing. The 3RW4436-6BC44 is supplied as genuine surplus or refurbished stock, not a grey-market copy.
What condition will the 3RW4436-6BC44 arrive in?
Units are supplied refurbished as standard, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa to confirm the current condition grade and availability.
How fast can Autronexa ship the 3RW4436-6BC44?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability, and we will confirm the shipping window for your order.
Does the 3RW4436-6BC44 support inside-delta circuit operation?
Yes. The data lists an inside-delta circuit rating of 281 A and 160 kW at 400 V, in addition to the standard circuit rating of 162 A and 90 kW.
Related & compatible parts
Siemens
3RW4423-1BC44
Genuine Siemens 3RW4423-1BC44 soft starter, surplus and refurbished, verified for 36A standard duty and 62A inside-delta operation.
Siemens
3RW4444-6BC44
Genuine Siemens 3RW4444-6BC44 soft starter for 250 A standard or 433 A inside-delta operation, sourced as verified surplus…
Siemens
3RW4435-6BC44
Genuine surplus Siemens 3RW4435-6BC44 soft starter with 75 kW standard rating and inside-delta capability, verified and ready to…
Siemens
1FK7022-5AK71-1LH0
Genuine surplus Siemens 1FK7022-5AK71-1LH0 servo motor with 0.38kW, 6000rpm, and IP64 protection. Verified condition and ready to ship…
News & guides for Siemens
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Siemens and NVIDIA’s Erlangen Blueprint: 85% Less Ramp-Up Engineering
Siemens and NVIDIA are turning the Erlangen electronics plant into a blueprint for AI-run factories. What the 85% and 20%…
Siemens spare parts: buying guide, series overview and how to order
Siemens spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…