ABB AI895
Analog Input Module
Genuine surplus ABB AI895 Analog Input Module — 8-channel 4...20 mA with HART and intrinsic safety. Verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Article number | 3BSC690086R1 |
|---|---|
| Signal specification | 4...20 mA |
| Number of channels | 8 |
| Signal type | Unipolar single ended |
| HART | Yes |
| Intrinsic safety | Yes |
| Resolution | 12 bit |
| Isolation | Groupwise isolated from ground |
| Operating temperature | 0 to +55 °C (+32 to +131 °F) |
| Compatibility | TU890, TU891 or TU891Z |
Description
For process plants running ABB S800 I/O, a failed analog input module stalls HART transmitter loops and forces costly emergency sourcing. The ABB AI895 Analog Input Module restores 8 channels of 4…20 mA input with built-in intrinsic safety, so you avoid both OEM lead times and the expense of external isolators. Autronexa supplies this module as verified genuine surplus, tested against OEM datasheet specifications.
What the AI895 Does in an S800 System
This unit is an 8-channel analog input module for single-ended, unipolar 4…20 mA signals. Each channel powers and monitors a two-wire process transmitter while preserving HART communication, so you keep digital diagnostics without extra hardware. Intrinsic safety protection is built into every channel, allowing direct connection to process equipment in hazardous areas — no additional external devices needed. That integration cuts both panel space and per-loop hardware cost compared with external isolator arrangements. The module also accepts 4-wire transmitters with a particular connection, retaining HART capability. Input voltage drop is typically 3 V including the PTC, and the transmitter supply delivers at least 15 V at 20 mA loop current, current-limited to 23 mA under overload. For Ex-certified two-wire transmitters, this means reliable loop power without a separate supply module.

Cost and Efficiency Implications of the Key Ratings
Every rating on this module has a budget consequence. The 12-bit resolution and typical 0.05% error (0.1% max) keep measurement uncertainty low, reducing calibration rework and product give-away. Groupwise isolation from ground protects the backplane from field faults, lowering repair costs across the I/O rack. The 20 ms input filter rise time (0–90%) smooths noisy process signals, which cuts nuisance alarms and unnecessary operator intervention. Power dissipation of 4.75 W and typical current draw of 130 mA from the +5 V Modulebus and 270 mA from +24 V external (max <370 mA) simplify power budgeting for the cabinet. With CMRR above 80 dB at 50/60 Hz, the module rejects common-mode noise that would otherwise distort readings and trigger false trips.

Surplus Sourcing and Compatibility Notes
Autronexa stocks genuine surplus and refurbished S800 modules because OEM lead times on discontinued or constrained lines can stretch production schedules. This unit is functionally verified by our sourcing team, and its condition is stated as refurbished. This unit works with TU890 Compact MTU for Ex applications and TU891 or TU891Z for non-Ex applications, enabling two-wire connections without additional terminals — a saving in both wiring time and terminal hardware. The keying code is AE; confirm your existing MTU keying before ordering. Operating temperature is 0 to +55 °C, dropping to 40 °C maximum ambient for vertical mounting in a compact MTU, so verify cabinet airflow. The module carries CE marking, ATEX/IECEx Zone 2 certification with interface to Zone 0, and marine approvals from ABS, BV, DNV and LR. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this ABB AI895 a genuine module or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. This is genuine ABB surplus, not a grey-market copy.
What condition will the AI895 arrive in?
The module is supplied refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the specific condition report on the unit in stock.
How fast can you ship the AI895?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus units typically ship faster than OEM factory lead times.
Does the AI895 work with TU890 and TU891 MTUs?
Yes. The module is compatible with TU890 for Ex applications and TU891 or TU891Z for non-Ex applications. Confirm the keying code AE matches your existing MTU before installation.
Is the AI895 still supported by ABB?
Lifecycle status is not stated in our current data. Contact Autronexa to verify OEM support status and availability before ordering.
Related & compatible parts
ABB
AI931N
Genuine surplus ABB AI931N HART analog input for S900 I/O — 4 channels, 0/4...20 mA, verified condition and…
ABB
DI803
Genuine surplus ABB DI803 8-channel digital input module for S800 I/O — verified condition, faster lead times than…
ABB
AO801
Genuine surplus ABB AO801 analog output module, 8 channels, 0–20 mA / 4–20 mA, verified condition and current…
ABB
V18345-1010221001
Genuine surplus ABB TZIDC-120 valve positioner, 4–20 mA two-wire, IP 65, with analog feedback. Verified condition, ready to…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…