ABB AI950S
Sturdy
Genuine surplus ABB AI950S temperature input module for S900 I/O — 4 isolated channels, ATEX Zone 1, PROFIBUS DP. Verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Article number | 3KDE175521L9500 |
|---|---|
| Number of channels | 4 |
| Input types | Pt100, Pt1000, Ni100 (2-/3-/4-wire); thermocouples B, E, J, K, L, N, R, S, T, U; mV |
| HART | Yes |
| Intrinsic safety | Yes |
| Hazardous location | ATEX Zone 1 |
| Operating temperature | -20 °C...60 °C |
| Dimensions (W×D×H) | 20 mm × 104 mm × 104 mm |
| Weight | 0.135 kg |
Description
Consider a process plant where a temperature transmitter in Zone 1 must feed an intrinsically safe signal back to the control system, and the existing I/O card has failed. The ABB AI950S temperature input module solves exactly that problem: it is a 4-channel analog input for the S900 I/O system, rated for ATEX Zone 1 installation and designed to connect intrinsically safe field devices from Zone 0, 1, or 2. For maintenance and procurement teams, sourcing a genuine surplus or refurbished unit like this one means restoring the loop without waiting on OEM lead times or paying full list price.
What the AI950S Does in an S900 System
This unit (article number 3KDE175521L9500) is a temperature input module (TI4-Ex) within ABB’s S900 I/O family. It accepts Pt100, Pt1000, and Ni100 sensors in 2-, 3-, or 4-wire technique, plus thermocouples of types B, E, J, K, L, N, R, S, T, and U, as well as mV signals. Each of the four channels is electrically isolated channel to channel, and the module provides isolation between input and bus as well as input and power. Short and break detection help flag wiring faults before they cause bad readings. Internal or external cold junction compensation is selectable. The module communicates with the control level over PROFIBUS DP, and its S900 mechanics allow installation directly in the field — reducing marshalling and wiring costs. Integrated disconnection mechanisms support replacement during operation, and hot-swap functionality means you can exchange the module without interrupting primary voltage.

Surplus Advantage for This Temperature Module
New-from-OEM lead times for S900 I/O modules can stretch weeks or months, especially for ATEX-rated variants. A genuine surplus or professionally refurbished unit gives you a practical alternative: the unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before it ships. Because this is an ATEX Zone 1 module, condition matters — you need a unit that has not been exposed to corrosive atmospheres beyond its G3 coating rating or to temperatures outside the -20 °C to 60 °C operating range. Autronexa verifies each module’s markings and part-number cross-reference so you receive a genuine ABB part, not a clone. For plants carrying spares of S900 hardware, this is a straightforward way to keep a critical temperature loop covered without tying up capital in a full-price OEM order.
Sourcing Checklist Before You Order
Confirm the exact article number 3KDE175521L9500 matches your backplane and system variant — the S900 family includes non-hazardous and hazardous-area versions, and This unit is specifically the Zone 1 type. Verify that your field devices are intrinsically safe and rated for the Zone 2, Zone 1, or Zone 0 connection you intend. Check whether your application requires HART communication (this module supports it) or SOE (it does not). Review the G3 coating suitability for your atmosphere and the 93 % relative humidity limit at 40 °C. If you are replacing an existing card, note any revision or firmware requirements from your system documentation. Autronexa can help cross-check these details against your installation; contact us with your part number for verified condition and current availability. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine ABB AI950S, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. The AI950S carries article number 3KDE175521L9500, and we confirm that before shipping.
What condition will the AI950S arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — contact us to confirm current stock condition.
How fast can you ship the AI950S?
Lead time depends on current stock. Contact Autronexa for current lead time and availability; surplus and refurbished units are typically ready to ship faster than OEM factory orders.
Does the AI950S work with PROFIBUS DP networks?
Yes — the S900 I/O system communicates with the control level using PROFIBUS DP. Confirm your network configuration and any required gateway or connection module with your supplier before installation.
Is the AI950S still supported by ABB?
Lifecycle status is not stated in our current data. Contact Autronexa to verify OEM support status and availability before ordering.
Related & compatible parts
ABB
SS823
Genuine surplus ABB SS823 voting unit for redundant power supplies — verified, tested, and ready for your AC…
ABB
TU810V1
Genuine surplus ABB TU810V1 compact MTU: 16 channels, 50 V, DIN rail mount, verified condition and clear lead…
ABB
DI831
Genuine surplus ABB DI831 16-channel 48 V d.c. digital input module for S800 I/O — verified condition, practical…
ABB
TB825
Genuine surplus ABB TB825 ModuleBus optical media converter — verified, tested, and ready to ship for S800 I/O…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…