Genuine surplus Schneider ATV610D18N4Z drive, 18.5 kW, 380...460 V, C3 EMC filter — verified condition and ready to ship from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated motor power | 18.5 kW (25 HP) normal duty; 15 kW (20 HP) heavy duty |
|---|---|
| Supply voltage | 380...460 V AC, 50/60 Hz, three-phase |
| Maximum continuous output current | 39.2 A (normal duty) |
| Maximum transient current (60 s) | 43.1 A (normal duty) |
| Integrated EMC filter | Category C3 |
| Dimensions (H×W×D) | 495 × 211 × 232 mm |
| Weight | 13.3 kg (29.32 lb) without packaging |
| Protection rating | IP20 (IP40 on the top of the product) |
| Operating temperature | -15...+45 °C without derating; up to +60 °C with power derating |
Description
How do you replace an 18.5 kW pump or fan drive without waiting weeks for an OEM build slot? The Schneider Electric ATV610D18N4Z variable speed drive is the answer many maintenance teams look for: an Easy Altivar 610 unit rated 18.5 kW (25 HP) normal duty on a 380…460 V three-phase supply, with an integrated Category C3 EMC filter and no integral keypad. Autronexa supplies it as genuine surplus or professionally refurbished stock, verified before dispatch.
What This Drive Does in a Pump or Fan System
The Easy Altivar 610 family is built around variable-torque loads, and this variant fits that role directly. Its quadratic U/f control profile (UFQ) matches the torque curve of centrifugal pumps and fans, so the drive can trim motor speed to demand instead of running a motor at full line frequency. The 18.5 kW normal-duty rating pairs with 39.2 A maximum continuous output current and 43.1 A transient current for 60 s. For heavier starts, the same frame carries a 15 kW heavy-duty rating at 31.7 A continuous and 47.6 A transient. Six 24 V DC digital inputs, three analog inputs and two analog outputs cover the usual feedback and command wiring, and Slot A accepts an Extended I/O module VW3A3203 or Extended relay module VW3A3204 when more points are needed. Note that this N4Z version ships without a display terminal; a VW3A1113 keypad connects through the RJ45 HMI port as a separate accessory.

Technical Specifications That Matter on Site
Three figures drive most installation decisions on this unit. First, the supply range of 380…460 V AC at 50/60 Hz three-phase, with maximum input current of 37.2 A at 380 V and 33.5 A at 460 V — useful when sizing upstream protection. Second, the 495 × 211 × 232 mm frame 3 enclosure at 13.3 kg, which sets cabinet depth and lifting arrangements; vertical mounting within ±10° is required for cooling. Third, the thermal budget: 474 W total dissipation at nominal current, with operation from -15…+45 °C without derating and up to +60 °C with power derating. The IP20 rating (IP40 on top) suits enclosed cabinets rather than washdown areas. Modbus RTU is built in through the RJ45 field-network port, and Slot A can take a PROFIBUS DP V1 module VW3A3607 if the plant network requires it. Integration Note: wiring into such networks may require an external gateway or connection module — confirm required cables and gateways with your supplier.

Why Genuine Surplus Fits This Model
A drive in this power class is rarely a stock item on a maintenance shelf, yet a failed unit stops the process immediately. Autronexa holds surplus and refurbished Easy Altivar 610 units so buyers can avoid an OEM lead time on a part that is still an active product line. Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before it is listed — genuine parts, verified, not grey-market substitutes. The practical trade-off is straightforward: you get a traceable Schneider drive at a cost below OEM list, with condition stated up front. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this ATV610D18N4Z a genuine Schneider Electric drive, or a copy?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before listing. This is genuine Schneider Electric stock, supplied as surplus or professionally refurbished — not a clone or grey-market substitute.
What condition will the drive arrive in?
Units are supplied in the site default condition, Refurbished, meaning tested against OEM datasheet specifications and functionally verified by our sourcing team. Any specific grading is confirmed in writing before dispatch.
How quickly can Autronexa ship this drive?
Lead time depends on current stock at the time of your request. Contact Autronexa with the part number for verified condition and current availability; surplus and refurbished units are ready to ship once confirmed.
Does this version include a display keypad?
No. The N4Z version ships without an integral plain-text display terminal. A VW3A1113 keypad can be connected through the RJ45 HMI port as a separate accessory if local configuration access is needed.
Can this drive run on a Modbus network?
Yes. Modbus RTU is built in through one of the two RJ45 ports. For PROFIBUS DP, Slot A accepts the VW3A3607 communication module, which must be ordered separately.
Related & compatible parts
Schneider Electric
140NOC78000C
Genuine surplus Schneider Electric 140NOC78000C Ethernet DIO module for Modicon Quantum — verified condition, faster than OEM lead…
Schneider Electric
140DRC83000C
Genuine surplus Schneider Electric 140DRC83000C Modicon Quantum discrete output module — 8 channels, verified condition, ready to ship.
Schneider Electric
TSXCTY2C
Genuine surplus Schneider TSXCTY2C counter module: 2 channels, 1 MHz, 24 V sink inputs. Verified condition, ready to…
Schneider Electric
BMXRMS128MPF
Genuine surplus Schneider Electric BMXRMS128MPF 128MB SD flash memory card for Modicon M340 processors — verified condition, ready…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…