Schneider Electric Circuit Protection
Schneider Electric iC60N 3P C63
Circuit Breaker
Genuine surplus Schneider Electric iC60N 3P C63 miniature circuit breaker — 63A, C-curve, 6 kA, verified condition and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated current | 63A |
|---|---|
| Poles | 3P |
| Trip curve | C (thermal-magnetic, magnetic trip 8×In ±20%) |
| Breaking capacity | 6 kA @ 230/400V (IEC 60898-1) |
| Rated voltage | 400V AC |
| Standard | EN/IEC 60898-1, EN/IEC 60947-2 |
| Operating temperature | -35 to 70 °C |
| Mounting | 35 mm DIN rail |
| Mechanical life | 20,000 cycles |
| Electrical life | 10,000 cycles |
| Dimensions (H×W×D) | 85 × 54 × 78.5 mm |
| Weight | 0.375 kg |
Description
When a 63A three-pole feeder trips and will not reset, every hour offline adds cost. The Schneider Electric iC60N 3P C63 miniature circuit breaker from the Acti9 iC60 range is the drop-in replacement maintenance teams ask for — and Autronexa supplies it as a verified surplus or refurbished unit, so you avoid OEM lead time without accepting grey-market risk.
What This Breaker Does on Your Panel
The iC60N 3P C63 is a thermal-magnetic miniature circuit breaker rated 63A with a C trip curve, where the magnetic element trips at 8×In ±20%. That curve tolerates brief inrush from motor and transformer loads while still clearing short circuits decisively. Three poles switch a 400V AC three-phase circuit together, and the 6 kA breaking capacity at 230/400V to IEC 60898-1 covers the fault levels of most distribution boards downstream of a main breaker. The unit clips onto 35 mm DIN rail, measures 85 × 54 × 78.5 mm and weighs 0.375 kg, so it fits standard enclosure widths without re-drilling. It is built to EN/IEC 60898-1 and EN/IEC 60947-2, and rated for operation from -35 to 70 °C.

Why Sourcing This Model as Surplus Makes Sense
Lifecycle data confirms this configuration is active in production in the Acti9 range, verified in September 2026, so availability is not the problem — price and speed often are. A genuine surplus unit gives you the same Schneider Electric part at a lower cost than OEM list, and every unit we ship is checked against OEM datasheet markings and functionally verified by our sourcing team before dispatch. For a breaker that is already in service across your plant, matching the exact model, pole count and curve matters more than buying new; a mislabelled clone can leave a feeder under-protected. Refurbished stock is tested against OEM datasheet specifications, and surplus stock is verified genuine parts. If you maintain several Acti9 boards, keeping one spare of this rating on the shelf shortens every future changeover.
Selection and Service Notes for Maintenance Teams
Before ordering, confirm the panel schedule calls for a 63A C-curve device and not a B or D curve, and check that the outgoing cable and busbar arrangement suits a three-pole unit of this width. Inspect the DIN rail clip and terminal screws on arrival, torque terminations to the manufacturer’s specification, and record the installation date so the 20,000 mechanical and 10,000 electrical cycle ratings can be tracked against service history. Periodic inspection of terminal tightness and a visual check for discolouration remain the practical reliability routine. Please verify current lifecycle status and availability with Autronexa before ordering, and contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this iC60N 3P C63 a genuine Schneider Electric breaker or a copy?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. You receive a genuine Schneider Electric device, not a clone.
What condition will the breaker arrive in?
Units ship as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available and are verified genuine parts.
How fast can you ship this model?
Contact Autronexa for current lead time and stock status. Surplus and refurbished units are ready to ship once condition is confirmed against your order.
Does the 6 kA rating suit my distribution board?
The breaker is rated 6 kA at 230/400V to IEC 60898-1. Compare that with the prospective fault level at the installation point; if your board exceeds it, specify a higher breaking capacity device.
Is the Acti9 iC60 range still supported by Schneider Electric?
Lifecycle data verified in September 2026 lists this configuration as active in production within the Acti9 range. Confirm current OEM support status with Autronexa when ordering.
Related & compatible parts
Schneider Electric
ATV320U11N4C
Genuine surplus Schneider ATV320U11N4C drive, 1.1 kW, tested and verified. Sourcing help and clear lead times from Autronexa.
Schneider Electric
140CHS41010
Genuine surplus Schneider 140CHS41010 hot standby kit for Modicon Quantum redundancy — verified condition, ready to ship.
Schneider Electric
140DDO35301
Genuine surplus Schneider 140DDO35301: 32-output DC module for Modicon Quantum, verified and ready to ship from Autronexa.
Schneider Electric
140DDO35310C
Genuine surplus Schneider Electric 140DDO35310C Modicon Quantum 32-channel discrete output module — verified condition, sourcing support from Autronexa.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…