Schneider Electric Communication Modules
Schneider Electric 170INT11000C
Interbus Communication Adaptor
Genuine surplus Schneider 170INT11000C Interbus adaptor — verified, tested, and ready to ship for Modicon Momentum systems.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Product Line | Modicon Momentum |
|---|---|
| Transmission Rate | 500 kbit/s |
| Transmission Support Medium | Twisted Pair |
| Topology | Ring |
| Number of Devices Per Segment | 0 to 254 |
| Max Cable Distance Between Modules | 12800 m |
| Fail State | Fail Safe |
| Protection Class | IP20 |
| Resistance to Electrostatic Discharge | 8 kV |
| Resistance to Electromagnetic Fields | 10 V/m |
| Operating Altitude | 5000 m |
Description
The 170INT11000C is a Schneider Electric Interbus communication adaptor for the Modicon Momentum platform, built for engineers who need reliable 500 kbit/s data transfer across ring-topology networks. Genuine surplus stock offers a practical alternative to OEM lead times without compromising authenticity. Autronexa verifies each unit against OEM datasheet markings and functionally tests it before shipping.
What This Adaptor Does in a Momentum System
This module connects Modicon Momentum I/O to an Interbus generation SUPI 2 network over twisted-pair cable. It supports ring topology with up to 254 devices per segment and a maximum cable distance of 12,800 m between modules — enough to cover large plant footprints without additional repeaters. The fail-safe state ensures that if the network drops, connected devices default to a safe condition rather than an undefined state. With an IP20 protection class and conformal coating (Humiseal 1A33 TC), the unit is suited to control cabinets where particulate ingress and moderate electrical noise are present. It withstands 8 kV electrostatic discharge and 10 V/m electromagnetic fields, and operates at altitudes up to 5000 m.

Surplus Advantage for This Interbus Adaptor
Interbus is a legacy fieldbus, and sourcing genuine Schneider adaptors through official channels often means long lead times or minimum order quantities that don’t match maintenance needs. Autronexa holds surplus and refurbished units of this adaptor, each verified against OEM datasheet specifications and functionally tested by our sourcing team. You get a genuine part with traceable condition — not a grey-market clone — and a lead time that fits planned shutdowns or emergency replacements. For engineers maintaining Momentum systems, this is a practical way to keep spares on the shelf without paying OEM list prices.

Selection and Sourcing Guide
When specifying this adaptor, confirm the exact part number 170INT11000C and check that your network uses Interbus generation SUPI 2 with twisted-pair cabling. Verify the ring topology and device count per segment (0 to 254) match your architecture. If you are replacing a failed unit, inspect the existing module for conformal coating condition and any revision markings. Autronexa can cross-reference your requirements and provide current availability. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric 170INT11000C, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We source only genuine surplus and refurbished components, not grey-market copies.
What condition will the 170INT11000C arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — contact us for current stock condition.
How fast can you ship the 170INT11000C?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability — we prioritize urgent maintenance requests.
Does this adaptor work with Modicon Momentum I/O?
Yes, it is designed for the Modicon Momentum platform and supports Interbus generation SUPI 2 over twisted-pair cable with ring topology.
Is the 170INT11000C still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and availability before ordering.
Related & compatible parts
Schneider Electric
170AMM09000
Genuine surplus Schneider Electric 170AMM09000 I/O base module — verified condition, tested against OEM specs, ready to ship.
Schneider Electric
140DDI15310
Genuine surplus Schneider Electric 140DDI15310 Modicon Quantum 32-point TTL 5V DC input module — verified condition, faster than…
Schneider Electric
TM3AQ4
Genuine surplus Schneider Electric TM3AQ4 analog output module — 4 channels, 12-bit, verified condition and ready sourcing support.
Schneider Electric
TWDAMM3HT
Genuine surplus TWDAMM3HT analog I/O module for Schneider Twido base units — verified condition, sourcing help from Autronexa.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes