Schneider Electric I/O & Function Modules
Schneider Electric 170PBI03001
Terminal connection base
Genuine surplus Schneider Electric 170PBI03001 terminal connection base for Modicon Momentum I/O — verified condition, sourcing help, faster than OEM.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Series | Modicon Momentum |
|---|---|
| Description | Terminal connection base for 170 series I/O modules |
| Compatible with | 170 series discrete and analog I/O modules |
| Terminal type | Screw/clamp terminal |
| Protection rating | IP20 |
| Certifications | CE, UL, CSA |
| Lifecycle | Discontinued (Last verified: 2026-09) |
Description
Consider a Modicon Momentum rack where a 170 series I/O module is ready to install but the wiring interface is missing — without the terminal connection base, the module cannot land field wiring, and the line stays down. The Schneider Electric 170PBI03001 is the screw/clamp terminal base that closes that gap for 170 series discrete and analog I/O modules.
What This Terminal Base Does in a Momentum Rack
The 170PBI03001 is a terminal connection base built for the Modicon Momentum family. It provides the screw/clamp terminal interface between a 170 series I/O module and the field wiring, so discrete and analog signals have a defined landing point. The base carries an IP20 protection rating, which suits it to cabinet-mounted installations where the assembly sits inside an enclosure rather than in the open. CE, UL, and CSA certifications are stated for this part, which matters when the panel has to pass inspection. Because the base is dedicated to the 170 series, matching it to the correct I/O module is the first check before ordering.

Sourcing a Discontinued Momentum Base
Schneider Electric lists this terminal base as discontinued, last verified in 2026-09. That changes the sourcing picture: OEM channels may no longer carry it, and buyers are left comparing surplus stock against waiting on a replacement path. Autronexa holds genuine surplus and refurbished automation components, and units are tested against OEM datasheet specifications and functionally verified by our sourcing team before they ship. For a discontinued base like this one, that verification is the practical difference between a part that installs cleanly and one that stalls a restart. Surplus and refurbished stock also typically moves faster than an OEM lead time on an end-of-life item.
What to Confirm Before You Order
Three checks protect a Momentum retrofit or repair. First, confirm the I/O module is a 170 series discrete or analog unit — the base is specified for those modules only. Second, confirm the terminal style matches your wiring plan; this base uses screw/clamp terminals. Third, confirm the condition you are buying: surplus, refurbished, or otherwise, and ask for the verification details. Autronexa can cross-reference the part number against OEM markings and provide current availability. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric 170PBI03001, or a clone?
Autronexa sources genuine surplus and refurbished units and verifies them against OEM datasheet markings and part-number cross-reference before listing. Ask our sourcing team for the verification details on the specific unit in stock.
What condition will the terminal base arrive in?
The site default condition is Refurbished: units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Confirm the condition of the current stock with Autronexa before ordering.
How fast can you ship the 170PBI03001?
Lead time is not stated in the available data. Contact Autronexa with your part number for current availability and lead time; surplus stock generally moves faster than an OEM path on a discontinued item.
Which I/O modules does this base fit?
It is specified as compatible with 170 series discrete and analog I/O modules in the Modicon Momentum family. Confirm your exact module is a 170 series unit before ordering.
Is the 170PBI03001 still supported by Schneider Electric?
The available data lists it as discontinued, last verified 2026-09. Contact Autronexa to verify current OEM support status and remaining availability.
Related & compatible parts
Schneider Electric
TSXCANCA300
Genuine surplus Schneider Electric TSXCANCA300 CANopen cable, 300 m, IP20, IEC 60332-1 — verified condition and practical lead…
Schneider Electric
TSXETG100
Genuine surplus Schneider TSXETG100 Ethernet Modbus gateway/router — verified condition, practical lead times, engineering sourcing support.
Schneider Electric
TSXMRPC001M
Genuine surplus Schneider TSXMRPC001M SRAM memory for TSX Micro PLCs — verified condition, 192–1024 kB capacity, ready to…
Schneider Electric
ABFM04S200
The Schneider Electric ABFM04S200 cable connector is built for reliable analog output connections within the Modicon Quantum series.…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…