Schneider Electric PLCs & Controllers
Schneider Electric 171CCC76010
M1/M1E Processor Adapter Module
Genuine surplus Schneider 171CCC76010 M1/M1E processor adapter for Modicon Momentum — verified condition, faster than OEM lead times.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Product Line | Modicon Momentum |
|---|---|
| Processor | X86 based (INTEL, AMD), 32 MHz |
| Memory | 512 KB flash, 512 KB RAM; program 18 kB LL984 / 240 kB IEC; data 24 kB |
| Supply Voltage | 5.0 V DC ±5% (from Momentum I/O base) |
| Communication | Modbus; 1 non-isolated RS-232C port, 1 I/O bus port |
| I/O Capacity | 8,192 bits max (discrete); 26,048 I/O registers |
| Instruction Speed | 1 ms per 1,000 instructions |
| Operating Temperature | 0…60 °C (32…140 °F), non-condensing |
| Shock Resistance | ≤ 15 gn peak, 11 ms half sine wave |
Description
When a Modicon Momentum M1 or M1E processor drops offline, production visibility goes with it. The Schneider Electric 171CCC76010 processor adapter module is the genuine interface that restores that link — and Autronexa supplies it as verified surplus or refurbished stock, tested against OEM datasheet specifications and functionally verified by our sourcing team.
What This Adapter Does in a Momentum System
The 171CCC76010 is an M1/M1E processor adaptor for the Modicon Momentum automation platform. It supplies the processor with 5.0 V DC ±5% from the Momentum I/O base, so no separate power supply is required at the module. The X86-based processor runs at 32 MHz and executes 1,000 instructions in 1 ms, which suits deterministic control loops. Memory is split between 512 KB flash and 512 KB RAM, with program memory of 18 kB LL984 or 240 kB IEC and 24 kB data. Software support covers Concept V2.6, Modsoft V2.5 or later, ProWORX NxT V2.0 and ProWORX 32. Communication runs over Modbus through one non-isolated RS-232C port plus one I/O bus port.

Surplus and Refurbished: Why It Fits This Module
Momentum M1/M1E hardware is mature, and OEM lead times for adapter modules can stretch while a line waits. Genuine surplus and refurbished units close that gap. Each unit is checked against OEM datasheet markings and part-number cross-reference before dispatch, so you receive a genuine part, verified — not a grey-market substitute. This unit carries CE marking plus FM Class 1 Division 2, UL, cUL and Nema type 250 certifications, and we confirm those markings on every unit. Refurbished stock is tested against OEM datasheet specifications and functionally verified by our sourcing team. Please verify current lifecycle status and availability with Autronexa before ordering.

Choosing the Right Momentum Adapter
Buyers comparing this module with other Momentum processor adapters should confirm the processor family first: M1/M1E adapters differ from later Momentum CPU bases in supply arrangement and port count. Check the exact part number and revision against your existing module, and confirm whether your program uses LL984 or IEC memory sizing, because the 18 kB and 240 kB figures are not interchangeable. Also verify the RS-232C port is sufficient for your programming and Modbus needs; this unit has one non-isolated port and one I/O bus port. Autronexa helps match the adapter to your base and software version before shipment.
| Comparison | unit (this unit) | Typical OEM-new adapter | Generic grey-market unit |
|---|---|---|---|
| Authenticity | Verified against OEM markings | OEM direct | Often unverified |
| Condition | Refurbished, functionally tested | New | Unknown |
| Lead time | Surplus stock, ready to ship | Often extended | Variable |
| Cost | Below OEM list | Full list price | Low but risky |
| Support | Sourcing team help | OEM channel | Limited |
Frequently asked questions
Is this a genuine Schneider Electric 171CCC76010, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before dispatch. The module carries CE, FM Class 1 Division 2, UL, cUL and Nema type 250 markings as listed in the OEM data.
What condition will the 171CCC76010 arrive in?
Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — confirm the exact condition with Autronexa when you request a quote.
How fast can you ship the 171CCC76010?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus and refurbished units are ready to ship when in stock.
Does this adapter work with Modbus and my existing Momentum base?
Yes — the module communicates over Modbus through one non-isolated RS-232C port and one I/O bus port, and it is supplied by the Momentum I/O base at 5.0 V DC ±5%. Confirm your base model with Autronexa before ordering.
Is the 171CCC76010 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Please verify current lifecycle status and availability with Autronexa before ordering.
Related & compatible parts
Schneider Electric
140NOC78000C
Genuine surplus Schneider Electric 140NOC78000C Ethernet DIO module for Modicon Quantum — verified condition, faster than OEM lead…
Schneider Electric
BMENOP0300
Genuine surplus Schneider Electric BMENOP0300 communication module for Modicon M580 PACs — verified condition, ready to ship.
Schneider Electric
ATV320U40N4W
Genuine surplus Schneider ATV320U40N4W, 4 kW IP66 drive with integrated EMC filter — verified condition, ready to ship.
Schneider Electric
140CRA93101C
Genuine surplus Schneider Electric 140CRA93101C adapter module for Modicon Quantum — verified condition, practical lead times.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…