Schneider Electric Drives & Inverters
Schneider Electric ATV610D11N4
Variable speed drive
Genuine surplus Schneider ATV610D11N4 11 kW drive — verified condition, tested, and ready to ship from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated motor power (normal duty) | 11 kW (15 HP) |
|---|---|
| Rated motor power (heavy duty) | 7.5 kW (10 HP) |
| Supply voltage | 380...460 V AC, 50/60 Hz, three-phase |
| Maximum continuous output current | 23.5 A (normal duty) |
| Maximum transient current (60 s) | 25.9 A (normal duty) |
| Integrated EMC filter | Category C3 |
| Integrated HMI | Plain text display terminal VW3A1113 |
| Dimensions (H×W×D) | 360 × 171 × 233 mm |
| Weight | 7.73 kg (17 lb), without packaging |
| Protection rating | IP20 (IP40 on top) |
Description
The Schneider Electric ATV610D11N4 is an 11 kW (15 HP) normal-duty variable speed drive from the Easy Altivar 610 series, built for three-phase pumps and fans on a 380…460 V supply. Maintenance and procurement teams choose genuine surplus or refurbished units of this model when an OEM replacement lead time would stall a running process — Autronexa verifies each unit against OEM datasheet markings before it ships.
What This Drive Does in a Pump or Fan System
The Easy Altivar 610 family targets variable-torque HVAC and water applications, and this variant carries the ratings that matter for that duty. Normal duty is 11 kW (15 HP) with 23.5 A maximum continuous output current and 25.9 A transient current for 60 s; heavy duty drops to 7.5 kW with 16.5 A continuous. The integrated C3 EMC filter reduces the need for external filtering in many cabinet builds, and the plain text display terminal VW3A1113 (2 lines, white backlit LCD, RJ45) gives local access without a separate HMI purchase. A fan cooled design with a field-replaceable fan — under 5 minutes without special tools — keeps routine service practical. The drive accepts three-phase asynchronous and synchronous motors in open loop, with control modes including U/f Vc Quadratic (UFQ) for variable-torque fan and pump loads.

Technical Specifications That Shape the Installation
Three values drive most of the engineering decisions here. First, the supply range of 380…460 V AC at 50/60 Hz three-phase with 22 A maximum input current at 380 V and 19.6 A at 460 V sets the upstream protection and cabling. Second, the 15.6 kVA apparent power at 460 V and 22 kA maximum prospective short-circuit current inform the breaker and contactor selection. Third, the 364 W total power dissipation at nominal current (per installation manual EAV64381) must be removed from the enclosure — plan ventilation accordingly. The unit measures 360 × 171 × 233 mm and weighs 7.73 kg without packaging, frame size 2. Operating temperature is -15…+45 °C without derating, extending to +60 °C with power derating; altitude is up to 1000 m without derating. I/O includes 3 analog inputs, 6 digital inputs (2 programmable as pulse inputs), 2 analog outputs, and 3 relay outputs. Slot A accepts an Extended I/O module VW3A3203, Extended relay module VW3A3204, or PROFIBUS DP V1 module VW3A3607. Built-in communication is Modbus RTU over 2 RJ45 ports (one Modbus field network, one HMI multidrop).

Why Genuine Surplus Fits This Model
For a drive already installed in a pump or fan panel, the constraint is usually schedule, not specification. A refurbished ATV610D11N4 from Autronexa is tested against OEM datasheet specifications and functionally verified by our sourcing team, so the unit arrives with known condition rather than an unknown service history. The Easy Altivar 610 line remains active per the manufacturer’s official product pages (last verified 2026-10), which means surplus stock is a practical bridge when a new-unit lead time does not match a maintenance window. Before ordering, confirm the exact model and revision against your existing drive, and confirm whether your application needs the normal-duty 11 kW rating or the heavy-duty 7.5 kW rating — the two are not interchangeable. Please verify current lifecycle status and availability with Autronexa before ordering.
Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this ATV610D11N4 a genuine Schneider Electric drive or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before listing. The ATV610D11N4 is a genuine Schneider Electric Easy Altivar 610 drive, not a copy.
What condition will the drive arrive in?
Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade confirmed before purchase.
How fast can you ship the ATV610D11N4?
Lead time depends on current stock. Contact Autronexa for the current lead time and availability on this model before committing to a maintenance window.
Does this drive support Modbus communication out of the box?
Yes. The unit has built-in Modbus RTU over 2 RJ45 ports — one Modbus field network and one HMI multidrop. PROFIBUS DP V1 is available through the optional VW3A3607 module in Slot A.
Is the Easy Altivar 610 line still supported by Schneider Electric?
The manufacturer's official product pages were active as of 2026-10. Contact Autronexa to verify current OEM support status and lifecycle before ordering.
Related & compatible parts
Schneider Electric
JDL36225
SQUARE D JDL36225 Circuit Protection. Voltage rating: 600 V; Wire Size: 350 KCMIL. Current rating is 225 A.…
Schneider Electric
140CRA21120C
Genuine surplus Schneider Electric 140CRA21120C DIO drop interface for Modicon Quantum — verified condition and fast sourcing from…
Schneider Electric
TSXPSY1610M
Genuine surplus Schneider Electric TSXPSY1610M power supply for TSX Micro PLCs — verified, tested, and ready to ship…
Schneider Electric
TCSESM043F23F0
Genuine surplus Schneider ConneXium managed switch with 4 copper ports, HiPER ring redundancy, and verified condition from Autronexa.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…