| Rated motor power | 30 kW (40 HP) normal duty; 22 kW (30 HP) heavy duty |
|---|---|
| Supply voltage | 380...460 V AC, 50/60 Hz, three-phase |
| Maximum continuous output current | 61.5 A (normal duty) |
| Frame size | 4 |
| Dimensions (H×W×D) | 613 × 226 × 271 mm |
| Weight | 25.5 kg (56.2 lb), without packaging |
| Protection rating | IP20 (IP40 on the top of the product) |
| Operating temperature | -15...+45 °C without derating; up to +60 °C with power derating |
| Integrated HMI | Plain text display terminal VW3A1113 (2 lines, white backlit LCD, RJ45) |
| Built-in communication | 2 RJ45 ports; Modbus RTU |
Description
How do you keep a pump or fan line running when the drive that controls it fails and OEM lead times stretch out? The Schneider Electric ATV610D30N4 answers that question: a 30 kW (40 HP) normal-duty variable speed drive from the Easy Altivar 610 series, built for three-phase 380…460 V supplies and stocked by Autronexa as genuine surplus and refurbished automation hardware.
What This Drive Does in a Pump or Fan System
The unit is an AC frequency inverter for open-loop three-phase asynchronous and synchronous motors. It ships with a plain text display terminal VW3A1113, a two-line white backlit LCD with RJ45 connection, so operators can read and adjust parameters at the cabinet door. A Category C3 EMC filter is integrated, which simplifies compliance planning for the enclosure. Control modes cover U/f Vc Standard, 5-point and Quadratic curves for variable-torque fan and pump loads, plus open-loop synchronous motor and reluctance motor control. The drive carries six 24 V DC digital inputs, three analog inputs configurable for 0…10 V or 0…20 mA, two analog outputs and three relay outputs. Slot A accepts an Extended I/O module VW3A3203, an Extended relay module VW3A3204 or a PROFIBUS DP V1 module VW3A3607.

Technical Specs That Shape the Installation
At 30 kW normal duty the drive delivers 61.5 A continuous output and 67.7 A transient for 60 s; heavy duty is rated 22 kW at 46.3 A continuous. Maximum input current is 62.5 A at 380 V and 55.8 A at 460 V, with 44.5 kVA apparent power at 460 V. The frame 4 chassis measures 613 × 226 × 271 mm and weighs 25.5 kg. Power terminals take 12 N·m of tightening torque. Cabinet designers should plan for 740 W of dissipation at nominal current and keep top, bottom and front clearances of at least 100, 100 and 10 mm. The fan is field-replaceable in under five minutes without special tools, and the IP20 enclosure (IP40 on top) suits controlled cabinets. Operating range is -15…+45 °C without derating, extending to +60 °C with derating; altitude is rated to 1000 m without derating.

Why Genuine Surplus Makes Sense Here
The Easy Altivar 610 line is active, yet OEM lead times on a 30 kW frame can still stall a maintenance window. Autronexa holds surplus and refurbished units that are tested against OEM datasheet specifications and functionally verified by our sourcing team — genuine parts, verified before dispatch. For a pump or fan drive, the practical benefit is straightforward: you replace like for like without paying full list price, and you keep the existing wiring, EMC filter and terminal layout. Confirm your exact model and revision against the unit before ordering, and ask our team about current condition and lead time. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this ATV610D30N4 a genuine Schneider Electric drive or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. The drive is genuine Schneider Electric hardware, not a copy.
What condition will the drive arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a surplus unit instead.
How fast can Autronexa ship the ATV610D30N4?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability before ordering.
Does the drive support PROFIBUS DP?
Yes, when Slot A is fitted with the PROFIBUS DP V1 module VW3A3607. Built-in communication is Modbus RTU over the RJ45 field network port.
Is the Easy Altivar 610 line still supported by Schneider Electric?
Official product pages were active as of 2026-10. Contact Autronexa to verify OEM support status for your specific revision.
Related & compatible parts
Schneider Electric
ATV930C11N4C
Genuine surplus Schneider Electric ATV930C11N4C dual-rated 110 kW/90 kW drive — verified condition, faster than OEM lead time.
Schneider Electric
ATV930D37N4Z
Genuine surplus Schneider ATV930D37N4Z drive — dual-rated 37 kW ND / 30 kW HD, verified condition, ready to…
Schneider Electric
TM218LDAE24DRHN
Genuine surplus Schneider TM218LDAE24DRHN Modicon M218 controller — 24 I/O, relay outputs, Ethernet. Verified condition, faster than OEM…
Schneider Electric
BMENOS0300
Genuine surplus BMENOS0300 switch module for Modicon X80 — verified condition, faster lead times than OEM.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…