Schneider Electric Drives & Inverters
Schneider Electric ATV610D75N4
Variable speed drive
Genuine surplus Schneider ATV610D75N4 75 kW drive, verified and ready to ship from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated motor power | 75 kW (100 HP) normal duty; 55 kW (75 HP) heavy duty |
|---|---|
| Supply voltage | 380...460 V AC, 50/60 Hz, three-phase |
| Maximum continuous output current | 145 A (normal duty) |
| Maximum input current | 147.9 A at 380 V; 130.2 A at 460 V (normal duty) |
| Integrated EMC filter | Category C3 |
| Integrated HMI | Plain text display terminal VW3A1113 (2 lines, white backlit LCD, RJ45) |
| Protection rating | IP20 (IP40 on top) |
| Dimensions (H×W×D) | 762 × 290 × 323 mm |
| Weight | 53 kg (117 lb), without packaging |
Description
The Schneider Electric ATV610D75N4 is a 75 kW (100 HP) variable speed drive for pumps and fans, built for 380…460 V three-phase supply. Maintenance and procurement teams choose genuine surplus or refurbished units of this model to avoid OEM lead times while keeping verified authenticity. Autronexa supplies tested, traceable stock with practical sourcing support.
Product Overview
This drive belongs to the Easy Altivar 610 series and ships with an integrated C3 EMC filter and a plain text display terminal VW3A1113. It handles three-phase asynchronous and synchronous motors in open loop, with control modes including U/f Vc Standard (STD), 5-point (UF5), quadratic (UFQ) for variable-torque fan and pump loads, plus open-loop synchronous motor control (SYNU) and reluctance motor control (SRVC). The frame size 5 unit measures 762 × 290 × 323 mm and weighs 53 kg without packaging. I/O includes 6 digital inputs (2 configurable as pulse inputs), 3 analog inputs, 2 analog outputs, and 3 relay outputs. Slot A accepts an Extended I/O module VW3A3203 or Extended relay module VW3A3204, and built-in communication covers Modbus RTU via two RJ45 ports.

Key Electrical and Environmental Ratings
At 380 V the maximum input current is 147.9 A; at 460 V it is 130.2 A, with apparent power of 103.7 kVA at 460 V. Normal duty output is 145 A continuous and 160 A transient for 60 s, while heavy duty is rated 55 kW, 106 A continuous, and 159 A transient for 60 s. Overload capability reaches 110% of rated current for 60 s (or 120% for 20 s) in normal duty, and 150% for 60 s in heavy duty. The drive operates from -15…+45 °C without derating and up to +60 °C with power derating, at altitudes up to 1000 m without derating. Protection rating is IP20 (IP40 on top), and electronic cards carry a protective conformal coating. The integrated DC choke reduces harmonic distortion; an optional passive filter (VW3A460xx) can achieve THDi < 10%.

Surplus Advantage for This Drive
Autronexa stocks genuine surplus and refurbished Easy Altivar 610 units, including this 75 kW model, because OEM lead times on high-power drives can stall pump and fan projects. Each refurbished unit is tested against OEM datasheet specifications and functionally verified by our sourcing team. The fan is field-replaceable in under five minutes without special tools, which simplifies maintenance planning. The Easy Altivar 610 line remains active as of 2026-10, so lifecycle status is current. For buyers comparing against new-from-OEM or grey-market options, Autronexa provides verified condition, clear lead times, and technical sourcing help across Allen-Bradley, Bently Nevada, Siemens, Schneider and more. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this ATV610D75N4 a genuine Schneider Electric drive or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished Schneider Electric drives, not grey-market copies.
What condition will the ATV610D75N4 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — contact Autronexa to confirm current stock condition.
How fast can Autronexa ship the ATV610D75N4?
Lead time depends on current stock. Contact Autronexa for verified availability and a shipping estimate for this 75 kW drive.
Does the ATV610D75N4 support Modbus RTU?
Yes. The drive has two built-in RJ45 ports — one for Modbus field network and one for HMI multidrop — and supports Modbus RTU. Slot A can accept a PROFIBUS DP V1 module VW3A3607 if needed.
Is the ATV610D75N4 still supported by Schneider Electric?
The Easy Altivar 610 product line was active as of 2026-10 per official product pages. Contact Autronexa to verify current OEM support status before ordering.
Related & compatible parts
Schneider Electric
ATV310HU22N4E
Genuine surplus Schneider ATV310HU22N4E 2.2 kW drive — verified condition, faster than OEM lead times, with practical sourcing…
Schneider Electric
TSXETY4103
Genuine surplus Schneider TSXETY4103 Ethernet TCP/IP module for TSX Micro PLCs — verified condition, Modbus TCP and Uni-Telway,…
Schneider Electric
171CBU98090
Genuine surplus Schneider Electric 171CBU98090 Modicon Momentum PLC — verified condition, clear lead times, sourcing help from Autronexa.
Schneider Electric
BMEP582020H
Genuine surplus BMEP582020H M580 processor for severe environments — verified condition, faster than OEM lead times.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…