Schneider Electric Drives & Inverters
Schneider Electric ATV930D22N4
Variable speed drive
Genuine surplus Schneider ATV930D22N4 Altivar 930 drive — 22 kW ND/18.5 kW HD, 380–480 V, tested and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Motor power (ND / HD) | 22 kW (30 HP) / 18.5 kW (25 HP) |
|---|---|
| Supply voltage | 380...480 V three-phase, 50/60 Hz |
| Maximum continuous output current | 46.3 A (ND) / 39.2 A (HD) |
| Output frequency | 0.1...599 Hz |
| Integrated safety | STO, SIL3 / Cat. PL e per IEC 61508 and ISO 13849-1 |
| Built-in ports | Ethernet dual-port switch (RJ45); Modbus serial (RJ45) |
| Protection rating | IP21 / UL Type 1 |
| Dimensions (H×W×D) | 545.9 x 211 x 235 mm |
| Weight | 14.300 kg (31.526 lb) |
Description
When a 22 kW drive fails on a running line, every hour of downtime adds cost. The Schneider Electric ATV930D22N4 Altivar Process drive is the dual-rated ND/HD unit that keeps three-phase 380…480 V motors turning — and Autronexa supplies it as a verified genuine surplus or refurbished unit, tested against OEM datasheet specifications and functionally checked before dispatch.
What This Dual-Rated Drive Solves
Engineers specify the ATV930D22N4 when a single frame must cover two duty profiles. In Normal Duty it delivers 22 kW (30 HP) with 120% overload for 60 s; in Heavy Duty it delivers 18.5 kW (25 HP) with 150% overload for 60 s. That flexibility matters on mixed loads — a conveyor that runs light most of the day but starts under load, for example. The built-in dynamic brake transistor handles stopping energy without an external chopper, though a braking resistor of at least 15 Ω is still required. Integrated STO (SIL3 / Cat. PL e) supports machine-safety architectures without extra hardware. Output frequency spans 0.1…599 Hz, and motor control covers asynchronous, synchronous PM and synchronous reluctance motors in open- or closed-loop vector modes.

Why Genuine Surplus Beats Waiting on OEM Lead Time
A failed drive on a critical line rarely waits for a factory order. Autronexa holds surplus and refurbished Altivar Process units so maintenance teams can restore production without paying full OEM list price. Each unit is verified against OEM datasheet markings and part-number cross-reference — no clones, no grey-market copies. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. This unit is a current catalog model (catalog Nov 2019), so surplus availability varies; confirm current stock and lead time with Autronexa before committing to a delivery schedule.

Sourcing Checklist for This Frame
Before ordering, confirm the exact model string and revision, and decide whether your application needs the ND or HD rating — the same hardware carries both, but continuous current differs (46.3 A ND versus 39.2 A HD at nominal switching frequency). Check enclosure and environment: this frame is IP21/UL Type 1, rated -15 to +50 °C standard with derating to 60 °C, and requires 100 mm clearance above and below plus 10 mm at the front. If your network uses EtherNet/IP or Modbus TCP, the built-in dual-port switch covers it; other fieldbuses need the option slot. Autronexa can confirm condition grade and accessory compatibility from the unit’s test record. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this ATV930D22N4 a genuine Schneider Electric drive or a copy?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before listing. We supply genuine surplus and refurbished Schneider Electric drives, not clones or grey-market copies.
What condition will the drive arrive in?
Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — confirm the condition grade for your order with Autronexa.
How fast can you ship the ATV930D22N4?
Lead time depends on current stock of this frame. Contact Autronexa for current lead time and availability before committing to a delivery schedule.
Does this drive support EtherNet/IP and Modbus TCP?
Yes. The ATV930D22N4 has a built-in Ethernet dual-port switch (RJ45) supporting EtherNet/IP and Modbus TCP, plus a Modbus serial port (RJ45). Other fieldbuses such as PROFINET or EtherCAT require an option module in the single expansion slot.
Is the ATV930D22N4 still supported by Schneider Electric?
The Altivar Process ATV930 wall-mounting range appears in the current Schneider Electric catalog (Nov 2019). Contact Autronexa to verify OEM support status and lifecycle details for this specific unit.
Related & compatible parts
Schneider Electric
990XTS00300
Genuine surplus Schneider Electric 990XTS00300 conversion connector, 10A/250 VDC, Modicon Quantum — verified condition, ready to ship.
Schneider Electric
ATV930U75N4
Genuine surplus Schneider ATV930U75N4 dual-rated 7.5 kW drive — verified condition, faster than OEM lead time.
Schneider Electric
LMC058LF424
Genuine surplus Schneider LMC058LF424 Modicon LMC058 motion controller — 4 axes, 42 I/O, verified condition and clear lead…
Schneider Electric
JDL36225
SQUARE D JDL36225 Circuit Protection. Voltage rating: 600 V; Wire Size: 350 KCMIL. Current rating is 225 A.…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes