Schneider Electric PLCs & Controllers
Schneider Electric 140CPU42402C
CPU Module
Genuine surplus Schneider Electric 140CPU42402C Modicon Quantum CPU — verified condition, faster lead time than OEM, sourcing support from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Processor | 486 Controller CPU |
|---|---|
| Memory | 2 MB RAM |
| I/O Compatibility | Local & Remote I/O |
| Communication Ports | 2 x Modbus Plus (MB+) |
| Communication Protocols | Modbus, Modbus Plus |
| Instruction Set | IEC 61131-3 |
| Voltage Supply | 5 V DC |
| Operating Temperature | 0…60°C |
| Coating | Conformal Coated (CC) |
Description
When a Modicon Quantum controller fails, every hour of downtime adds cost. The Schneider Electric 140CPU42402C is a genuine surplus CPU module for local and remote I/O systems, offering a practical route to restoring control without OEM lead times or list pricing.
What This Quantum CPU Module Delivers
The 140CPU42402C pairs a 486 controller CPU with 2 MB RAM and built-in flash memory, so program storage and data handling stay on board without extra hardware. Its Boolean execution time of roughly 0.3 µs keeps scan cycles tight, which matters when a line runs many discrete operations per second. The module supports both local and remote I/O, giving you flexibility to place I/O where the process needs it rather than where the rack sits. Two Modbus Plus ports and Modbus protocol support mean the unit can join existing networks without a separate communication card. A conformal coating protects against dust and moisture, and an integrated watchdog timer helps the system recover from fault conditions. The instruction set follows IEC 61131-3, and the module is rack-mounted for straightforward installation in a control cabinet.

Why Genuine Surplus Makes Cost Sense Here
OEM lead times on legacy Quantum CPUs can stretch while a line waits. Genuine surplus and refurbished units change that equation. Each unit we source is tested against OEM datasheet specifications and functionally verified by our sourcing team, so you know the module meets the published performance before it ships. The cost saving versus OEM list price is real, and the lead time is typically shorter because the part is already in stock. For maintenance teams managing an aging Quantum installation, this is a practical way to keep spares on the shelf without committing to a full new-parts budget. The conformal coating and 0…60°C operating range suit cabinet environments where dust and temperature swings are part of daily operation.

Sourcing Checklist Before You Order
Verify the exact part number and any revision suffix on your existing module before ordering — Quantum installations often mix revisions across racks. Confirm whether your application uses local or remote I/O, since the module supports both but the rack configuration differs. Check that your programming environment is compatible with the Unity Pro or Concept platforms referenced in the datasheet. Decide between surplus and refurbished condition based on your spares policy; both are verified, but the grading differs. Ask about accessory compatibility if you are replacing a module in an existing rack. Autronexa can cross-reference your part number against OEM markings and confirm current availability. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric 140CPU42402C, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it ships. We source genuine surplus and refurbished modules only.
What condition will the 140CPU42402C arrive in?
Our default condition is refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the specific grading on current stock.
How fast can you ship the 140CPU42402C?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability.
Does this module work with Modbus Plus networks?
Yes — the datasheet lists two Modbus Plus ports and support for Modbus and Modbus Plus protocols. Confirm your network configuration with your supplier before ordering.
Is the 140CPU42402C still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before ordering.
Related & compatible parts
Schneider Electric
ATV310HU30N4S
Genuine surplus Schneider ATV310HU30N4S 3 kW drive — verified condition, Modbus RTU built in, ready to ship.
Schneider Electric
TM2DRA16RT
Genuine surplus Schneider Electric TM2DRA16RT discrete output module — 16 relay outputs, verified condition, ready to ship.
Schneider Electric
ABFM16H300
Genuine surplus Schneider Electric ABFM16H300 cabled connector for Modicon Quantum — 16 channels, 3 m cable, verified condition…
Schneider Electric
XBTGT1130
Genuine surplus Schneider XBTGT1130 HMI display: 3.8 in LCD, 320 x 240 pixels, Ethernet/RS232/RS485. Verified condition, ready to…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
