Schneider Electric I/O & Function Modules
Schneider Electric 140KRP10000
General-purpose I/O module
Genuine surplus Schneider 140KRP10000 I/O module for Modicon Quantum — verified condition, practical lead times, and sourcing support from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Operating Voltage | 24 V DC nominal |
|---|---|
| Input Voltage Threshold | 11–30 V DC (ON), 3–5 V DC (OFF) |
| Maximum Load Current | 0.65 A per channel, 10 A total |
| Isolation Voltage | 500 V transient protection |
| Update/Scan Time | ~15 ms |
| Bus Current Requirement | 350–550 mA |
| Operating Temperature Range | -10°C to +60°C |
| Mounting Method | Rack-mount, DIN rail option |
| IP Protection Rating | IP20 |
Description
When a Modicon Quantum rack loses an I/O module, every hour of downtime adds cost. The Schneider Electric 140KRP10000 general-purpose I/O module is the genuine replacement that keeps signal processing running at 24 V DC nominal — and sourcing it as verified surplus or refurbished stock is often faster than waiting on OEM channels. Autronexa supplies this unit with condition checked against OEM datasheet markings.
What This Quantum I/O Module Does
The 140KRP10000 sits in a Modicon Quantum system and handles input signal processing and management. Its input thresholds are 11–30 V DC for ON states and 3–5 V DC for OFF states, so field devices switching at 24 V DC are read cleanly without false transitions. Integrated filtering and surge suppression are built into the module, which reduces the chance of noise on the input lines reaching the controller. The unit draws 350–550 mA from the backplane bus, a figure worth checking against your rack power budget before you install it. Rack-mount is the standard installation; a DIN rail option is also supported for setups that need it.

Why Genuine Surplus Makes Sense Here
Quantum systems are long-lived, and replacement I/O modules are frequently needed years after the original installation. Autronexa stocks genuine surplus and refurbished units like this one, each tested against OEM datasheet specifications and functionally verified by our sourcing team. That means you get a part with confirmed input thresholds and bus current draw, not an untested pull. For maintenance managers comparing against brand-new distributor lead times, surplus stock often shortens the wait without compromising authenticity. If your rack needs a specific revision, tell us the details and we will match it.

Sourcing Checklist Before You Order
Confirm three things before committing: the exact part number on your existing module, the rack slot and backplane current available, and whether you need rack-mount or DIN rail installation. This unit is compatible with the Quantum series and Modbus/Profibus environments, so check that your system matches. Condition matters too — ask whether the unit is surplus or refurbished and request the verification notes. Autronexa provides sourcing help across Allen-Bradley, Bently Nevada, Siemens, Schneider and more, so if this module is not the right fit, we can help identify the correct one. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this 140KRP10000 a genuine Schneider Electric module or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished modules, not grey-market copies.
What condition will the 140KRP10000 arrive in?
Our default condition is refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask us for the specific condition notes on the unit in stock.
How fast can you ship the 140KRP10000?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability — we will confirm the shipping window before you order.
Does this module work with Modbus and Profibus systems?
The datasheet lists compatibility with the Quantum series and Modbus/Profibus environments. Confirm your backplane and rack configuration with our sourcing team before installation.
Is the 140KRP10000 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and availability before ordering.
Related & compatible parts
Schneider Electric · Advantys STB
STBDAI7220
Genuine surplus STBDAI7220 digital input module for Advantys STB systems — verified, tested, and ready to ship from…
Schneider Electric
171CCC98020
Genuine surplus Schneider 171CCC98020 processor adaptor module — Ethernet and Modbus, verified condition, ready to ship.
Schneider Electric
TSXP57453M
Genuine surplus Schneider TSXP57453M PL7 processor — verified condition, 16-rack support, up to 2040 discrete I/O, ready to…
Schneider Electric · Advantys STB
STBDAI5230
Genuine surplus STBDAI5230 digital input module — 2-channel 115V AC, hot-swappable, verified condition from Autronexa.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…