Schneider Electric Communication Modules

Schneider Electric 140NOA61110C

Communications Module

Manufacturer: Schneider Electric Part Number: 140NOA61110C

Genuine surplus Schneider Electric 140NOA61110C Interbus module for Modicon Quantum — verified condition, faster than OEM lead time.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Product Line Modicon Quantum
Module Type Interbus Communication Type
Operating Temperature 0 to 40 degrees Celsius
Storage Temperature 0 to 50 degrees Celsius
Maximum Operating Humidity 80% RH, non-condensing
Maximum Storage Humidity 80% RH, non-condensing
Maximum Operating Altitude 1000m above sea level
Maximum Storage Altitude 1000m above sea level
Operating Environment Clean indoor environment (no corrosive chemicals)

Description

Interbus Communications for Modicon Quantum

When an Interbus link drops on a running packaging or material handling line, every hour of downtime carries a cost. The Schneider Electric 140NOA61110C is a Modicon Quantum communications module built for Interbus communication, and sourcing a genuine unit quickly keeps that cost contained. Autronexa supplies verified surplus and refurbished units with clear lead times.

Figure 1: Front view of the Schneider Electric 140NOA61110C Communications Module showing its physical design and enclosure.

What This Module Does in a Quantum Rack

The module slots into a Modicon Quantum system and handles Interbus communication between the controller and connected field devices. Schneider Electric lists material handling, packaging, and textile machine applications among its supported uses, so it typically sits where conveyor, wrapping, or weaving equipment must exchange data with the PLC. Each of those applications depends on uninterrupted data flow; a failed module stops the line rather than slowing it, which is why buyers treat this part as a critical spare rather than a consumable. The module is specified for a clean indoor environment with no corrosive chemicals, so it belongs in standard control cabinets, not washdown or chemical-exposure areas. Please verify current lifecycle status and availability with Autronexa before ordering.

Figure 2: Technical layout and connection details for the Schneider Electric 140NOA61110C Communications Module.

Environmental Limits and Their Cost Impact

The published ratings are straightforward and worth checking against your cabinet conditions before you commit. Operating temperature runs from 0 to 40 degrees Celsius, while storage temperature extends to 0 to 50 degrees Celsius — a narrow window that makes cabinet cooling and ambient control part of the module’s cost of ownership. Maximum operating and storage humidity is 80% RH, non-condensing, and both operating and storage altitude are rated to 1000m above sea level. In practice, a cabinet that already runs warm or humid shortens service life and raises replacement frequency, so correcting ventilation is often cheaper than repeated module swaps. These figures come from the manufacturer’s published data for this configuration; confirm them against your installation before ordering.

Why Genuine Surplus Fits This Part

Interbus is a legacy fieldbus, and new-stock channels for Quantum communication modules are not always quick or inexpensive. Genuine surplus and refurbished units give maintenance teams a practical alternative: tested against OEM datasheet specifications and functionally verified by our sourcing team, at a fraction of full list price and without the wait that a factory order can involve. For a module whose failure stops a line outright, having a verified spare on the shelf is the cheapest insurance available. Autronexa stocks genuine surplus and refurbished automation components across Allen-Bradley, Bently Nevada, Siemens, Schneider and more, and our sourcing team can confirm condition and current availability against your exact part number. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is this a genuine Schneider Electric 140NOA61110C, or a clone?

Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it is listed. The module is supplied as genuine surplus or refurbished stock, not as a grey-market copy.

What condition will the module arrive in?

Units are supplied in the site default condition, Refurbished, meaning tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a surplus unit instead.

How fast can you ship the 140NOA61110C?

Lead time depends on current stock. Contact Autronexa for the current lead time and availability for your required quantity.

Can this module be used in a humid or high-altitude cabinet?

The published ratings are 80% RH non-condensing and 1000m maximum altitude for both operation and storage. Confirm your cabinet conditions against these figures before installation.

Is the 140NOA61110C still supported by Schneider Electric?

Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before ordering.

Related & compatible parts

Schneider Electric · Advantys STB

STBDDI3420

Genuine surplus Schneider Electric STBDDI3420 digital input module — 4 sink channels, hot-swappable, verified condition and clear lead…

In Stock

Schneider Electric

ATV610D37N4Z

Genuine surplus Schneider Electric ATV610D37N4Z 37 kW drive — verified condition, Modbus built in, ready to ship.

In Stock

Schneider Electric

BMXNOR0200H

Genuine surplus BMXNOR0200H Modicon X80 RTU serial module, conformal coated, Modbus RTU, verified condition and ready to ship.

In Stock

Schneider Electric

BMXP3420102CL

Genuine surplus Schneider Electric BMXP3420102CL processor module for Modicon M340 — verified condition, sourcing support, faster than OEM…

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: 140NOA61110C

We reply within one business day.

140NOA61110C Quote reply within 1 business day