Schneider Electric Communication Modules

Schneider Electric 140NWM05000

DIO head-end adaptor

Manufacturer: Schneider Electric Part Number: 140NWM05000

Genuine surplus Schneider Electric 140NWM05000 DIO head-end adaptor for Modicon Quantum — verified condition, faster lead time than OEM.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Product Line Modicon Quantum
IP Address Required
Door Removable
Interfaces RS-232, 100 Base-Fx, 10/100 Base-T
Bus Current 900 mA
Power Dissipation 4.5 W
Serial Port Bus Current 750 mA
Serial Port Power Dissipation 3.8 W
Operating Temperature 0 to 40 degrees Celsius
Maximum Operating Humidity 80% RH, non-condensing

Description

How do you keep a Modicon Quantum DIO segment communicating when the head-end adaptor fails and OEM lead times stretch? The 140NWM05000 from Schneider Electric is the DIO head-end adaptor that bridges the Quantum backplane to your network, and genuine surplus stock is often the fastest route back to service. This unit requires an assigned IP address and carries RS-232, 100 Base-Fx and 10/100 Base-T interfaces. Autronexa supplies verified surplus and refurbished units with clear condition notes.

What This Head-End Adaptor Does in a Quantum System

Within the Modicon Quantum framework, this adaptor handles the network-facing side of a distributed I/O segment. It is the point where the DIO drop connects to the wider control network, so a failure takes the whole segment offline rather than a single channel. The removable door simplifies access during installation and maintenance, and the diagnostics LEDs give technicians a front-panel view of link and module state during troubleshooting. Firmware is upgradable, which matters when a replacement must match the revision level of the existing segment. The unit draws 900 mA bus current with 4.5 W power dissipation; the serial port draws 750 mA and dissipates 3.8 W. No fuse is fitted.

Figure 1: Front view of the Schneider Electric 140NWM05000 DIO head-end adaptor showing its physical design and enclosure.

Technical Specs That Shape the Installation

Three values drive most of the installation planning. First, the IP address requirement: this is not a plug-and-play module, so the network address must be planned and assigned before the unit joins the segment. Second, the interface mix — RS-232, 100 Base-Fx and 10/100 Base-T — determines cabling and whether a fibre run is part of the architecture. Third, the thermal envelope: operating temperature is 0 to 40 degrees Celsius and storage is 0 to 50 degrees Celsius, with maximum humidity of 80% RH, non-condensing, in both states. Confirm the cabinet’s ambient conditions against those figures before commissioning, and keep the enclosure free of condensation.

Figure 2: Technical layout and connection details for the Schneider Electric 140NWM05000 DIO head-end adaptor.

Why Genuine Surplus Fits This Adaptor

Head-end adaptors sit at a single point of failure, so buyers rarely want to wait on a long OEM queue while a segment is down. Autronexa stocks genuine surplus and refurbished Quantum components, and refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. That gives you a practical alternative to full OEM list pricing without accepting unverified grey-market stock. Because the module is firmware upgradable, a verified unit can be brought to the revision your segment expects. Please verify current lifecycle status and availability with Autronexa before ordering, since Quantum stock moves quickly. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is this a genuine Schneider Electric 140NWM05000, or a clone?

Autronexa verifies units against OEM datasheet markings and part-number cross-reference before they enter stock. We supply genuine surplus and refurbished components, not copies.

What condition will the adaptor arrive in?

The site default condition is Refurbished: units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the specific condition note on the unit currently available.

How fast can you ship the 140NWM05000?

Lead time depends on current stock. Contact Autronexa for current lead time and availability; surplus Quantum parts move quickly, so confirm before ordering.

Does the module need an IP address before it will communicate?

Yes. The data states an IP address is required for this DIO head-end adaptor. Plan and assign the address before the unit joins the network segment.

Is the 140NWM05000 still supported by Schneider Electric?

Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before ordering.

Related & compatible parts

Schneider Electric

TM5ACBN1

Genuine surplus Schneider Electric TM5ACBN1 bus base module for Modicon TM5 — verified condition, practical lead times, sourcing…

In Stock

Schneider Electric

140NOM21200C

Genuine surplus Schneider 140NOM21200C DIO head-end adaptor for Modicon Quantum — verified condition, ready to ship.

In Stock

Schneider Electric

140NOA62200C

Genuine surplus Schneider Electric 140NOA62200C Interbus master module for Modicon Quantum — verified condition, practical sourcing support.

In Stock

Schneider Electric

140DDM69000

Genuine surplus Schneider Electric 140DDM69000 discrete I/O module for Modicon Quantum — 4 inputs, 4 outputs, verified condition.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: 140NWM05000

We reply within one business day.

140NWM05000 Quote reply within 1 business day