Schneider Electric Communication Modules

Schneider Electric 172PNN21022C

Communication adaptor

Manufacturer: Schneider Electric Part Number: 172PNN21022C

Genuine surplus Schneider Electric 172PNN21022C Modbus adaptor for Modicon Momentum — verified condition, faster lead times than OEM.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Product Line Modicon Momentum
Communication Type Modbus
Rated Supply Voltage 5 V DC
Supply Via I/O Base
Current Consumption 700 mA
Electrical Connection 1 Connector D-shell 9 pins
Battery Type / Size Lithium / 2/3 AA
Clock Drift Plus/Minus 13 s/day
Dielectric Strength 500 V DC
Material Lexan

Description

The Schneider Electric 172PNN21022C is a Modbus communication adaptor for the Modicon Momentum series, operating at 5 V DC with 700 mA current draw. Maintenance and procurement teams choose genuine surplus or refurbished units to avoid OEM lead times and list prices while keeping legacy Momentum I/O bases communicating reliably.

What This Adaptor Does in a Momentum System

The 172PNN21022C slots into a Modicon Momentum I/O base and draws its 5 V DC supply directly from that base — no separate power supply or wiring run is needed. It handles Modbus communication for the connected I/O, so the adaptor is the link between field signals and the controller or network master. The D-shell 9-pin connector provides the physical interface, and an integrated LED gives local status indication so technicians can confirm communication health without a laptop. The unit includes a lithium 2/3 AA battery and a clock drift of plus/minus 13 s/day, which supports time-dependent functions where exact second-level precision is not critical. The Lexan housing measures 1 inch high, 5.6 inches wide and 2.3 inches deep at 85.05 grams, and the 500 V DC dielectric strength covers the isolation expected in industrial panels.

Figure 1: Front view of the Schneider Electric 172PNN21022C Communication adaptor showing its physical design and enclosure.

Surplus Advantage: Cost and Lead-Time Math

A failed communication adaptor stops the I/O base from reporting to the controller, and every hour of that downtime carries a cost. OEM channels for older Momentum components often mean extended lead times and full list pricing. Autronexa stocks genuine surplus and refurbished units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. For this adaptor, the practical savings show up in three places: the unit price versus OEM list, the shorter lead time that gets the line back online, and the avoided cost of replacing an entire I/O base when only the adaptor has failed. Because the part is a plug-in module, swapping a verified unit restores Modbus communication without re-engineering the panel.

Figure 2: Technical layout and connection details for the Schneider Electric 172PNN21022C Communication adaptor.

Sourcing Checklist Before You Order

Confirm the exact part number and that your application uses Modbus communication, since this adaptor is configured for that protocol only. Check whether your existing unit is a surplus or refurbished item and ask for the condition grade in writing. Verify that the D-shell 9-pin connector on your cable matches, and note that the internal lithium 2/3 AA battery and the plus/minus 13 s/day clock drift are part of the assembly — ask whether the battery has been checked. Autronexa can cross-reference markings and provide current availability. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is this a genuine Schneider Electric 172PNN21022C, or a clone?

Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished Schneider Electric components, not grey-market copies.

What condition will the 172PNN21022C arrive in?

Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask for the condition grade in writing when you request a quote.

How fast can you ship the 172PNN21022C?

Lead time depends on current stock. Contact Autronexa for current lead time and availability — surplus units typically move faster than OEM factory orders.

Does this adaptor work with my Modicon Momentum I/O base?

The 172PNN21022C is configured for Modbus communication and draws its 5 V DC supply from the I/O base. Confirm your base model and protocol with Autronexa before ordering.

Is the 172PNN21022C still supported by Schneider Electric?

Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before you commit to a maintenance plan.

Related & compatible parts

Schneider Electric

AS-B873-011

Genuine surplus Schneider Electric AS-B873-011 Modicon analog input module, 4 points, 4–20 mA, verified and ready to source.

In Stock

Schneider Electric

ATV320U30N4B

Genuine surplus Schneider ATV320U30N4B 3 kW drive — verified condition, faster than OEM lead time, with sourcing support…

In Stock

Schneider Electric

BMXDDO1602

Genuine surplus BMXDDO1602 discrete output module — 16 outputs, 24 V DC, verified condition and faster lead time…

In Stock

Schneider Electric · Advantys STB

STBACO8220

Genuine surplus Schneider STBACO8220: 2-channel HART analog output, 4-20 mA, 15-bit, hot-swappable. Verified condition, sourcing help from Autronexa.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: 172PNN21022C

We reply within one business day.

172PNN21022C Quote reply within 1 business day