Technical specifications
| Motor power | 2.2 kW (3 HP) at 380...500 V three-phase |
|---|---|
| Supply voltage | 380...500 V three-phase (-15%/+10%), 50/60 Hz |
| Nominal output current | 5.5 A maximum at 4 kHz switching frequency |
| Protection rating | IP66 |
| Integrated EMC filter | Yes (category C2) |
| Dimensions (H×W×D) | 340 x 250 x 235 mm |
| Weight | 7.700 kg (16.975 lb) |
| Operating temperature | -10 to +50 °C without derating |
| Output frequency | 0.1 to 599 Hz |
Description
When a washdown-area conveyor or outdoor pump loses its drive, every hour of downtime hurts. The Schneider Electric ATV320U22N4W is a 2.2 kW, 380–500 V three-phase variable speed drive in an IP66 wall-mount enclosure with a category C2 integrated EMC filter — a genuine surplus unit that Autronexa verifies against OEM datasheet markings before it ships.
Built for Harsh Enclosures, Not Just Clean Panels
The most common failure point in food-processing or wastewater installations is moisture ingress into a standard IP20 drive. This Altivar Machine ATV320 variant solves that with a sealed IP66 housing measuring 340 x 250 x 235 mm and weighing 7.700 kg. The integrated category C2 EMC filter removes the need for a separate external filter, which simplifies panel space and wiring. The drive accepts 380…500 V three-phase input at 50/60 Hz, delivers 5.5 A nominal continuous output current at the 4 kHz factory switching frequency, and handles 150% overload for 60 s. Output frequency spans 0.1 to 599 Hz, covering both standard induction motors and synchronous PM motor control without a sensor. For engineers replacing a failed unit in a washdown zone, the IP66 rating and C2 filter are the two specifications that most often decide whether a substitute drive is acceptable.

Why Genuine Surplus Beats Waiting on a New Build
OEM lead times on active drive lines can stretch when a specific rating and enclosure combination is backordered. Autronexa holds surplus and refurbished Altivar Machine units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. For this 2.2 kW frame, the practical advantage is straightforward: you get the exact IP66, C2-filtered configuration without waiting for a factory build slot. The drive carries UL 508C, UL61800-5-1, CSA 22.2 N274, and IEC 61800-3 category C2/C3 certifications, and its safety architecture supports STO up to SIL3/PLe — so a verified surplus unit keeps your existing safety validation intact. Every unit is checked for part-number match and enclosure condition before dispatch, and we confirm current availability before you commit.

Sourcing Checks Before You Install
Three details decide whether this drive drops into your application. First, confirm the supply voltage: the unit is rated for 380…500 V three-phase with -15%/+10% tolerance, so a 400 V or 480 V site both qualify. Second, plan the motor cable: maximum shielded length is 10 m at 4 kHz under category C2, which matters on long conveyor runs. Third, allow 100 mm minimum clearance around the drive for vertical mounting at ±10°. If your panel uses an optional communication module — Modbus TCP/EtherNet/IP, PROFIBUS DP V1, DeviceNet, EtherCAT, POWERLINK, or PROFINET — the built-in RJ45 port covers CANopen and Modbus Serial line, and the expansion slot accepts the rest. Autronexa can confirm the exact revision and accessory compatibility before shipping. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this ATV320U22N4W a genuine Schneider Electric drive, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. The drive you receive is a genuine Schneider Electric Altivar Machine ATV320, not a grey-market copy.
What condition will the drive arrive in?
This unit is supplied in refurbished condition, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the specific condition grading of the unit currently in stock.
How fast can you ship the ATV320U22N4W?
Lead time depends on current stock at the time of order. Contact Autronexa with your part number and we will confirm availability and dispatch timing before you commit.
Does this drive work with my existing Modbus or Ethernet network?
The built-in RJ45 port supports CANopen and Modbus Serial line. For Modbus TCP/EtherNet/IP, PROFIBUS DP V1, DeviceNet, EtherCAT, POWERLINK, or PROFINET, the drive requires an optional communication module in its expansion slot — confirm the correct module with Autronexa before ordering.
Is the ATV320U22N4W still supported by Schneider Electric?
The Altivar Machine ATV320 is an active product line per the official Schneider Electric catalog (April 2020, last verified 2026-10). Contact Autronexa to verify current OEM support status for this specific rating.
Related & compatible parts
Schneider Electric
ATV310HD15N4E
Genuine surplus Schneider ATV310HD15N4E drive — 15 kW heavy duty, 380–460 V, Modbus RTU. Verified condition and fast…
Schneider Electric
140NOC77100C
Genuine surplus Schneider Electric 140NOC77100C TCP/IP module for Modicon Quantum — verified condition, practical lead times, sourcing help…
Schneider Electric
BMXCPS3500
Genuine surplus Schneider Electric BMXCPS3500 Modicon X80 power supply — 36 W, 100-240 V AC input, verified condition…
Schneider Electric
ATV610D22N4
Genuine surplus Schneider ATV610D22N4 drive — 22 kW, 380...460 V, Modbus, C3 EMC filter. Verified condition and clear…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…