Technical specifications
| Number of racks | 8 |
|---|---|
| Local I/O capacity (discrete) | 4096 I/O |
| Local I/O capacity (analog) | 1024 I/O |
| Remote I/O stations | 16 (2 remote drop) |
| Program memory | 16 MB |
| Integrated connections | 1 Ethernet TCP/IP service port, 2 Ethernet TCP/IP device network, USB mini B |
| Current consumption | 295 mA at 24 V DC |
| Operating temperature | 32…140 °F (0…60 °C) |
| IP degree of protection | IP20 |
| Net weight | 1.872 lb (0.849 kg) |
Description
When a Modicon M580 rack loses its processor, the whole line stalls. The BMEP584040 from Schneider Electric is a standalone processor module built to keep high‑density I/O systems running, and sourcing a genuine surplus or refurbished unit gets you back online without the OEM lead time. Autronexa verifies every module against OEM datasheet markings so you receive a genuine part, not a clone.
What This Processor Delivers in a Running System
The BMEP584040 handles the core control tasks for Modicon M580 architectures. It supports up to 8 racks and 16 remote I/O stations (with 2 remote drops), giving you room to scale. Local I/O capacity reaches 4096 discrete and 1024 analog points, plus 144 application‑specific channels for counter, SSI encoder, motion control, HART, and serial link functions. The integrated Ethernet TCP/IP service port and two device network ports simplify connectivity to distributed equipment — up to 64 devices. With 16 MB of program RAM and 4 GB expandable flash, this module suits complex process control and programmable loop applications. The 30 Kinst/ms Boolean instruction rate keeps scan times predictable.

Why Surplus Beats Waiting on a Factory Order
OEM lead times for active Modicon M580 processors can stretch weeks or months, and a single failed module can idle an entire production line. Autronexa stocks genuine surplus and professionally refurbished units like this one, tested against OEM datasheet specifications and functionally verified by our sourcing team. You get the same form, fit, and function without the new‑from‑OEM price tag. Because we specialise in automation components across Allen‑Bradley, Bently Nevada, Siemens, and Schneider, we understand the urgency of a processor failure. Every unit we ship is inspected for firmware integrity, memory health, and Ethernet port function. Surplus and refurbished, ready to ship — with clear lead times confirmed before you commit.

Sourcing Checklist for This Processor Module
Before ordering a replacement unit, confirm the exact revision and firmware level your application requires. Check that your rack configuration matches the 8‑rack and 16‑remote‑station capacity of this unit. Verify the condition: Autronexa supplies refurbished modules by default, but surplus units may also be available — ask for current stock. Ensure your cybersecurity requirements align with the embedded firewall, IPSec, and Achilles certification features listed in the datasheet. For legacy M580 systems, please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this BMEP584040 a genuine Schneider Electric module or a clone?
Autronexa verifies every processor module against OEM datasheet markings and part‑number cross‑reference. We supply genuine surplus and refurbished units only — no clones or grey‑market copies.
What condition will the BMEP584040 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — contact us for current stock and condition details.
How fast can you ship the BMEP584040?
Lead time varies with stock. Contact Autronexa for current availability and lead time — we confirm before you order.
Does this processor work with my existing Modicon M580 racks?
The BMEP584040 supports up to 8 racks and 16 remote I/O stations (2 remote drops). Confirm your rack configuration and firmware revision with our sourcing team before ordering.
Is the BMEP584040 still supported by Schneider Electric?
Please verify current lifecycle status and availability with Autronexa before ordering. We can check OEM support status and recommend alternatives if needed.
Related & compatible parts
Schneider Electric
TSXMRPC007M
Genuine surplus Schneider Electric TSXMRPC007M memory module for TSX Micro PLCs — 512 KB flash, verified condition, ready…
Schneider Electric
TSXCANCBDD5
Genuine surplus Schneider Electric TSXCANCBDD5 CANopen cordset, 5 m, dual SUB-D9, IP20 — verified condition and clear lead…
Schneider Electric
170BNP67100
Genuine surplus Schneider Electric 170BNP67100 Modbus Plus communication module for Modicon Momentum — verified condition, sourcing support.
Schneider Electric
TSXMFPP128K
Genuine surplus Schneider Electric TSXMFPP128K Flash EPROM memory module — 128 kB for Modicon Premium processors, verified condition.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…