| Channels | 8 channels |
|---|---|
| Signal type | Voltage / current |
| Resolution | 12-bit |
| Accuracy | <= 0.25% FS |
| Isolation | Group-to-group isolation |
| Supply voltage | 24 V DC (via backplane) |
| Power consumption | 1.8 W |
| Operating temperature | 0°C to +60°C |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 100 × 28 × 93 mm |
Description
The BMXAMO0802 is an 8-channel analog output module from Schneider Electric’s Modicon X80 series, used by maintenance and controls teams to drive voltage or current loops in M340 and M580 systems. Genuine surplus stock lets you replace a failed output card without paying OEM list price or waiting on a factory lead time.
What This Output Module Does in Your System
This module converts controller data into eight configurable voltage or current outputs, with 12-bit resolution and accuracy of <= 0.25% FS. That accuracy matters when a loop controls a valve or drive: a tighter error band means less trim work at commissioning and fewer rejected batches downstream. Group-to-group isolation separates output groups, which limits fault propagation between loops and protects the rest of the rack. A module status LED gives front-panel diagnostics without pulling the card. The 40-pin terminal block connection keeps wiring consistent with the existing Modicon X80 platform, so a replacement does not force re-termination of the field harness.

Surplus Advantage: Cost and Uptime
A failed analog output card stops the loops it drives, and every hour of downtime adds cost. Buying new from the OEM often means a quoted lead time and full list price. Genuine surplus and refurbished units change that equation: our sourcing team tests each module against OEM datasheet specifications and functionally verifies it before it ships. Because this platform is shared between M340 and M580, demand is steady and surplus units move quickly. The lifecycle status is Active (shared I/O platform for M340 and M580), last verified 2026-09, so support and spares remain available. Choosing verified surplus here typically shortens the replacement cycle and reduces spend versus a new-unit purchase, without accepting an unverified clone.

Sourcing Checklist for This Module
Before you order, confirm the exact model and revision match your rack, and check whether your application needs voltage or current output configuration. Verify the condition grade you are buying: surplus, refurbished, or new. Confirm that your existing 40-pin terminal block and field wiring are compatible, since the module itself does not include the harness. Ask for the test record if your maintenance procedure requires documented verification. Autronexa supplies genuine surplus and refurbished automation components and can cross-reference the part number against OEM markings. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this BMXAMO0802 a genuine Schneider Electric module or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before listing. We supply genuine surplus and refurbished components, not grey-market copies.
What condition will the BMXAMO0802 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available; confirm the grade you need when you request a quote.
How fast can you ship the BMXAMO0802?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus and refurbished units are ready to ship when in stock.
Does this module work with both M340 and M580 controllers?
Yes. The lifecycle data lists this as an active shared I/O platform for M340 and M580, so the module fits both families. Confirm your rack and terminal block compatibility before ordering.
Is the BMXAMO0802 still supported by Schneider Electric?
Lifecycle status is Active (shared I/O platform for M340 and M580), last verified 2026-09. Contact Autronexa to confirm current OEM support status and availability.
Related & compatible parts
Schneider Electric
ATV310HU40N4S
Genuine surplus Schneider ATV310HU40N4S drive — 4 kW heavy duty, 380–460 V three-phase, Modbus RTU, verified and ready…
Schneider Electric
BMXXCAUSBH045
Genuine Schneider BMXXCAUSBH045 Modicon X80 USB programming cable, 4.5 m — verified surplus stock with clear lead times.
Schneider Electric
ABFM08S202
Genuine surplus ABFM08S202 cabled connector for Modicon Quantum — 8 channels, 2 m shielded cable, verified condition.
Schneider Electric
ATV610C40N4
Genuine surplus ATV610C40N4 from Schneider Electric: 400 kW normal duty, 380...460 V, Modbus, C3 EMC filter. Verified condition,…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…