Genuine surplus BMXDDM16025 mixed I/O module — 8 DI + 8 relay DO, verified condition, faster than OEM lead times.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Channels | 16 channels (8 DI + 8 DO) |
|---|---|
| Signal type | DI: 24V DC positive logic 3.5mA; DO: relay |
| Range | DI: 24 V DC; DO: 24-240 V AC / 19-30 V DC |
| Isolation | Input-to-output isolation |
| Supply voltage | 24 V DC / field supply |
| Power consumption | 2.6 W |
| Bus current | 110 mA @ 24 V DC |
| Operating temperature | 0°C to +60°C |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 100 × 28 × 93 mm |
Description
How do you keep a Modicon M340 or M580 line running when a mixed I/O module fails and the OEM lead time stretches on? The Schneider Electric BMXDDM16025 answers that question: a 16-channel Modicon X80 mixed discrete I/O module with 8 DC inputs and 8 relay outputs, available through Autronexa as genuine surplus or professionally refurbished stock, verified before it ships.
What This Mixed I/O Module Does in a Modicon X80 Rack
The BMXDDM16025 combines two functions in one X80 slot: eight 24 V DC positive-logic inputs drawing 3.5 mA, and eight relay outputs rated for 24–240 V AC or 19–30 V DC. That mix lets a single module read field sensors and switch contactors, solenoids or interposing relays without adding a second card. Input-to-output isolation separates the DC sensing side from the relay side, and a module status LED gives a quick visual check during commissioning. The unit draws 2.6 W and 110 mA at 24 V DC on the bus, and connects through a 20-pin terminal block. Because the X80 platform is shared between M340 and M580 controllers, the same module serves both families — useful when a spare has to cover several racks.

Surplus and Refurbished: Why It Fits This Module
Schneider lists this module as active, yet OEM lead times on individual X80 modules can still stretch when demand spikes. Genuine surplus and refurbished stock closes that gap. Every unit Autronexa supplies is checked against OEM datasheet markings and functionally verified by our sourcing team, so you get a tested module rather than an unknown pull. Refurbished units are tested against OEM datasheet specifications and functionally verified — genuine parts, verified. For maintenance teams holding a line on a failed channel, that means a practical alternative to waiting on a factory order, with condition and lead time confirmed before you commit.

Sourcing Checklist Before You Order
Match the exact part number and confirm the revision level on the label, since X80 modules have evolved over the platform’s life. Decide whether your application needs surplus (pulled from service, tested) or refurbished (professionally restored and verified) condition, and confirm the 20-pin terminal block arrangement matches your existing wiring. Check that the relay output range suits your load — 24–240 V AC or 19–30 V DC — and that the 0 °C to +60 °C operating range fits the cabinet. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this BMXDDM16025 a genuine Schneider Electric module or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished modules, not copies.
What condition will the BMXDDM16025 arrive in?
Units ship in the condition listed at the time of order — typically refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Confirm the exact condition with Autronexa before ordering.
How fast can Autronexa ship the BMXDDM16025?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus and refurbished units are ready to ship when in stock.
Does the BMXDDM16025 work in both M340 and M580 racks?
Yes. Schneider lists the Modicon X80 platform as shared between M340 and M580 controllers, so this module fits either family. Confirm your rack and terminal block arrangement with Autronexa.
Is the BMXDDM16025 still supported by Schneider Electric?
Schneider's lifecycle data lists this module as active as of the last verification. Contact Autronexa to confirm current OEM support status and availability before ordering.
Related & compatible parts
Schneider Electric
ATV930C11N4C
Genuine surplus Schneider Electric ATV930C11N4C dual-rated 110 kW/90 kW drive — verified condition, faster than OEM lead time.
Schneider Electric
TSXDSY16S5
Genuine surplus Schneider TSXDSY16S5 discrete output module — 16 triac-protected outputs, 48–240 V AC, verified and ready to…
Schneider Electric
ATV310HD18N4EF
Genuine surplus Schneider ATV310HD18N4EF drive, 18.5 kW heavy duty, 380–460 V three-phase, with integrated C3 EMC filter. Verified…
Schneider Electric
140CPU65160C
Genuine surplus Schneider Electric 140CPU65160C Unity Processor — verified condition, Modicon Quantum series, ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…