Schneider Electric I/O & Function Modules
Schneider Electric BMXDDO1612
Output Module
Genuine surplus BMXDDO1612: 16-channel 24V DC transistor output module for Modicon X80, verified and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Channels | 16 channels |
|---|---|
| Signal type | Transistor output (source type) |
| Output range | 24 V DC, 0.625 A per channel (10 A module max) |
| Response time | 1.2 ms |
| Isolation | Output-to-logic isolation |
| Connection | 20-pin terminal block |
| Power consumption | 1.8 W |
| Operating temperature | 0°C to +60°C |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 100 × 28 × 93 mm |
Description
When a Modicon X80 rack needs a discrete output module and the OEM channel is quoting weeks out, the BMXDDO1612 from Schneider Electric is the practical answer for maintenance and procurement teams. Autronexa supplies this 16-channel, 24 V DC transistor (source) output module as genuine surplus, verified against OEM datasheet markings before it ships.
What This Modicon X80 Module Does in the Rack
The BMXDDO1612 is a discrete output slice for the Modicon X80 shared I/O platform used across M340 and M580 systems. It provides 16 source-type transistor outputs rated at 24 V DC, 0.625 A per channel, with a 10 A module maximum. Output-to-logic isolation separates field wiring from the backplane, and a 1.2 ms response time keeps discrete commands timely for relays, contactors, and solenoid-driven actuators. Module-level and per-channel LEDs let a technician identify a faulted point without pulling out a meter. The 20-pin terminal block connection keeps field wiring consistent with the rest of the rack, and the 100 × 28 × 93 mm housing fits standard X80 slot spacing. At 1.8 W power consumption and 75 mA bus current at 24 V DC, the electrical load on the rack stays modest.

Why Genuine Surplus Fits This Output Module
Lifecycle data lists this platform as active, shared between M340 and M580, last verified in September 2026. That matters because active platforms stay in production, and a failed output slice still stops a line even when the controller is healthy. OEM lead times can stretch when a specific reference is backordered, while surplus and refurbished stock is already on the shelf. Every unit Autronexa lists is inspected, functionally verified by our sourcing team, and described honestly — genuine parts, verified, with condition and availability confirmed before you commit. For a module that sits in a running rack, that shorter path from request to installed part is the real value.

Sourcing Checklist Before You Order
Confirm the exact reference on the failed slice matches unit, since X80 racks accept several output variants with different signal types and channel counts. Check whether your application needs source transistor outputs, as this module provides, rather than relay or sink types. Verify the 20-pin terminal block and existing field wiring are compatible with the replacement. Decide between surplus and refurbished condition based on your spares policy, and ask for the verified condition of the specific unit. The operating range of 0°C to +60°C and IP20 protection rating suit cabinet-mounted installations, so confirm your enclosure environment matches. Please verify current lifecycle status and availability with Autronexa before ordering, and contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this BMXDDO1612 a genuine Schneider Electric module or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before listing. The module is genuine Schneider Electric surplus, not a grey-market copy.
What condition will the BMXDDO1612 arrive in?
Units ship in the condition stated on the listing — refurbished stock is tested against OEM datasheet specifications and functionally verified by our sourcing team. Confirm the condition of the specific unit with Autronexa before ordering.
How fast can Autronexa ship this output module?
Lead time depends on current stock. Contact Autronexa with the part number for verified condition and current availability; surplus and refurbished units are typically ready to ship once confirmed.
Does the BMXDDO1612 work in both M340 and M580 racks?
Yes. Lifecycle data lists the Modicon X80 platform as shared I/O for M340 and M580 systems, so this output slice fits both families.
Is the BMXDDO1612 still supported by Schneider Electric?
Lifecycle data lists the platform as active, last verified in September 2026. Please verify current lifecycle status and availability with Autronexa before ordering.
Related & compatible parts
Schneider Electric
ATV71HU55N4
Genuine surplus Schneider ATV71HU55N4 Altivar 71 drive, 5.5 kW, verified condition and ready to ship from Autronexa.
Schneider Electric · Advantys STB
STBAVI1270
Genuine surplus STBAVI1270: 2-channel ±10V analog input for Advantys STB. Verified condition, faster than OEM lead time.
Schneider Electric
140CPS11400
Genuine surplus Schneider 140CPS11400 power supply — 8A, 24V DC, DIN rail, verified condition with clear lead times.
Schneider Electric
171CCC96030
Genuine surplus Schneider Electric 171CCC96030 M1/M1E Processor Adapter Module — verified condition, Ethernet-ready, ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…