Schneider Electric I/O & Function Modules
Schneider Electric FBM216
Module
Genuine surplus Schneider Electric FBM216 HART redundant input module — 8 isolated channels, verified condition, faster than OEM lead times.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Supported HART Instrument Types | HART instruments compliant to Version 5, 6, or 7 |
|---|---|
| Interface | 8 individually isolated channels |
| Communication to the Device | Point-to-point, master/slave, asynchronous, half-duplex, at 1200 baud |
| Speed | 2 messages per second |
| Maximum Distance (FBM216b to Field Device) | Up to 3030 m (10000 ft), meets HCF_SPEC-54 Revision 8.1 |
| Analog Accuracy | ±0.075% of full scale |
| Resolution | 15 bits |
| Input Voltage Range (Redundant) | 24 V dc +5% -10% |
| Operating Temperature | -20 to +70°C (-4 to +158°F) |
Description
When HART instruments on a running process need a reliable input path, the Schneider Electric FBM216 redundant input interface module keeps eight isolated channels communicating. This genuine surplus unit suits maintenance and automation teams who need verified Foxboro I/A Series hardware without waiting on OEM lead times.
What This Module Does in a HART Loop
The FBM216 sits between field instruments and the control system, handling HART communication across eight individually isolated channels. It supports instruments compliant with HART Version 5, 6, or 7 and communicates point-to-point, master/slave, asynchronous, half-duplex at 1200 baud. Error checking uses parity on each byte plus one CRC check byte, and the module processes 2 messages per second. The fastest allowed ECB block period is 100 msec, though Foxboro recommends checking the Sizing Guidelines and Excel Workbook for your Control Processor to set optimal loading. Maximum distance from This unitb to a field device meets the HART FSK physical layer specification HCF_SPEC-54, Revision 8.1, up to 3030 m (10000 ft). Each channel provides an isolated 24 V DC ±10% supply for the field device, with loop supply output impedance of 20 Ω including the termination assembly. Internal loop supply compliance voltage at the termination assembly is 18.5 V DC minimum at 20.5 mA.

Signal Accuracy and Isolation You Can Verify
Analog accuracy including nonlinearity is ±0.075% of full scale with a temperature coefficient of 50 PPM/°C. Resolution is 15 bits, update rate 100 ms, and integration time 500 ms. Common mode rejection exceeds 100 db at 50 or 60 Hz, while normal mode rejection exceeds 35 db at 50 or 60 Hz — figures that matter when nearby drives or power circuits inject noise. Each channel is individually galvanically isolated, current limited, and voltage regulated. All field connections are limited by design to less than 37 mA with a single module installed, or 72 mA when redundant modules are installed. The isolation is designed to withstand a common mode potential of 600 V AC applied for one minute between isolated input circuits and earth, or between any channel and another. The module requires I/A Series software v8.2 to v8.8 or Foxboro Evo Control Core Services software v9.0 or later.

Why Genuine Surplus Fits This Module
Autronexa supplies genuine surplus and refurbished automation components, and this unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch. For legacy Foxboro I/A Series installations, OEM lead times on interface modules can stretch while a process waits. A verified surplus unit gives you a practical path to restore redundant HART input capability without paying a brand-new list price. Power consumption is 7 W maximum with heat dissipation of 4 W maximum, and the module is rated for -20 to +70°C operation and Class G3 harsh environments per ISA S71.04. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this FBM216 a genuine Schneider Electric module or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. This is a genuine surplus Foxboro (by Schneider Electric) module, not a grey-market copy.
What condition will the FBM216 arrive in?
The site default condition is Refurbished: units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade confirmed before purchase.
How fast can you ship the FBM216?
Lead time depends on current stock at the time of your request. Contact Autronexa for current lead time and availability; surplus and refurbished units are ready to ship once verified.
Does this module work with my existing I/A Series control system?
The module requires I/A Series software v8.2 to v8.8 or Foxboro Evo Control Core Services software v9.0 or later. Confirm your software version with Autronexa before ordering.
Is the FBM216 still supported by Schneider Electric?
Lifecycle status is not stated in our source data. Contact Autronexa to verify OEM support status and current availability for this part number.
Related & compatible parts
Schneider Electric
LMC058LF42S0
Genuine surplus Schneider LMC058LF42S0 logic controller — 42 I/O, dual-core ARM, verified condition and clear lead times from…
Schneider Electric
170ENT11000
Genuine surplus Schneider Electric 170ENT11000 Ethernet adapter for Modicon Momentum — verified, tested, and ready to ship.
Schneider Electric
140XCA71706
Genuine surplus Schneider Electric 140XCA71706 backplane expander cable for Modicon Quantum — verified condition, 2 m PROFIBUS connectors.
Schneider Electric
140CRA21120C
Genuine surplus Schneider Electric 140CRA21120C DIO drop interface for Modicon Quantum — verified condition and fast sourcing from…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…