Schneider Electric Circuit Protection
Schneider Electric iC60N 2P C32
Circuit Breaker
Genuine surplus Schneider Electric iC60N 2P C32 circuit breaker — verified, tested, and ready to ship with clear lead times.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Poles | 2P |
|---|---|
| Rated current | 32A |
| Trip curve | C (thermal-magnetic, magnetic trip 8×In ±20%) |
| Breaking capacity | 6 kA @ 230/400V (IEC 60898-1) |
| Rated voltage | 400V AC, 125V DC |
| Operating temperature | -35 to 70 °C |
| Mounting | 35 mm DIN rail |
| Mechanical life | 20,000 cycles |
| Electrical life | 10,000 cycles |
| Dimensions (H×W×D) | 85 × 36 × 78.5 mm |
Description
When a 2-pole miniature circuit breaker trips on a live panel, every hour of downtime adds cost. The Schneider Electric iC60N 2P C32 is a genuine surplus option: a 32 A, C-curve Acti9 device that Autronexa verifies against OEM datasheet markings before it ships.
What This Acti9 iC60N Breaker Does in a Panel
The iC60N 2P C32 sits in the Acti9 iC60 family of miniature circuit breakers, a range Schneider Electric lists as active in production. Its job is straightforward: protect two circuits or a two-phase load against overload and short circuit. The C trip curve uses thermal-magnetic protection with a magnetic trip at 8×In ±20%, which suits loads that draw moderate inrush current without nuisance tripping. Rated current is 32 A, and breaking capacity is 6 kA at 230/400V under IEC 60898-1. The device accepts 400V AC or 125V DC, so it can serve in AC distribution boards and certain DC control circuits. Two poles in one body save DIN rail space compared with two single-pole devices.

Technical Specs Breakdown
Three values matter most when replacing this breaker. First, the 6 kA breaking capacity at 230/400V tells you the fault level the device can safely interrupt under IEC 60898-1; check it against your panel’s calculated fault current. Second, the C curve with magnetic trip at 8×In ±20% defines which loads it tolerates — motor and transformer circuits with moderate inrush are typical candidates, while high-inrush loads may need a different curve. Third, endurance: 20,000 mechanical cycles and 10,000 electrical cycles give you a realistic idea of remaining service life in a refurbished unit. The breaker mounts on 35 mm DIN rail, measures 85 × 36 × 78.5 mm, weighs 0.25 kg, and operates from -35 to 70 °C. It is built to EN/IEC 60898-1 and EN/IEC 60947-2.
Surplus Advantage and Sourcing Guide
A genuine surplus or refurbished unit often reaches a maintenance team faster than an OEM factory order, and at a lower cost than full list price. Autronexa sources these units as surplus and refurbished stock, then verifies each one against OEM datasheet markings and part-number cross-reference. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Before ordering, confirm the exact model and pole configuration, and decide whether you need surplus or refurbished condition. Compare this 32 A C-curve 2-pole device with a 1-pole unit when only one circuit needs protection, or with a higher-breaking-capacity model when fault levels exceed 6 kA. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric iC60N 2P C32, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it ships. We source genuine surplus and refurbished components, not grey-market copies.
What condition will the breaker arrive in?
Our default condition is Refurbished: each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus condition may also be available — confirm with Autronexa when you order.
How fast can you ship the iC60N 2P C32?
Lead time depends on current stock. Contact Autronexa for current lead time and availability; surplus and refurbished stock is often ready to ship faster than an OEM factory order.
Does this breaker work in a 400V AC panel?
Yes. The rated voltage is 400V AC, 125V DC, with 6 kA breaking capacity at 230/400V under IEC 60898-1. Confirm your panel's fault level does not exceed that rating.
Is the iC60N 2P C32 still supported by Schneider Electric?
Schneider Electric lists the Acti9 iC60 range as active in production (last verified 2026-09). Contact Autronexa to confirm current OEM support status for your specific revision.
Related & compatible parts
Schneider Electric
170BDO94650
Genuine surplus Schneider Electric 170BDO94650 output module — 16 AC outputs, 115–230V, verified condition and clear lead times…
Schneider Electric
140CPU53414UC
Genuine surplus Schneider Electric 140CPU53414UC CPU Module — verified condition, Modicon Quantum Unity processor, ready to ship.
Schneider Electric
172JNN21032
Genuine surplus Schneider Electric 172JNN21032 serial link adapter for Modicon Momentum — verified condition, ready to ship.
Schneider Electric
140NWM10000C
Genuine surplus Schneider Electric 140NWM10000C LED operator panel for Modicon Quantum — verified condition, practical lead times.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…