Schneider Electric Circuit Protection

Schneider Electric LC1G2654KUEN

Contactor

Manufacturer: Schneider Electric Part Number: LC1G2654KUEN

Genuine surplus Schneider Electric LC1G2654KUEN contactor — 4-pole, 385A AC-1, wide-band coil. Verified condition, ready to ship.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Poles description 4P (4 NO)
[Ie] rated operational current 385 A (at <40 °C) at <= 1000 V AC-1; 265 A (at <60 °C) at <= 440 V AC-3
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz; <= 460 V DC
[Uc] control circuit voltage 100…250 V AC 50/60 Hz; 100…250 V DC
[Uimp] rated impulse withstand voltage 8 kV
Mechanical durability 8 Mcycles
Dimensions (H x W x D) 225 x 185 x 226 mm
Net weight 8.2 kg
IP degree of protection IP2X front face with shrouds

Description

The Schneider Electric LC1G2654KUEN is a TeSys Giga high-power contactor built for demanding power switching: four normally-open poles, 385 A AC-1 rating, and a wide-band 100…250 V AC/DC coil. Maintenance and procurement teams choose genuine surplus or refurbished units of this model when OEM lead times stretch and production cannot wait.

Why the TeSys Giga Family Changed High-Power Switching

High-power contactor design has shifted over the past decade. Where older frames demanded bulky coils and frequent replacement, the TeSys Giga range introduced built-in bidirectional peak limiting and a wide control-voltage window. This unit reflects that evolution: its coil accepts 100…250 V AC 50/60 Hz or 100…250 V DC, so one stock item covers multiple control circuits. The four-pole configuration (4 NO) with a 385 A AC-1 rating at <40 °C suits power switching where continuous current matters more than motor starting alone. Rated operational voltage reaches <= 1000 V AC 50/60 Hz and <= 460 V DC, while the 8 kV impulse withstand voltage and 1000 V rated insulation voltage place it firmly in industrial distribution and heavy machinery panels.

Figure 1: Front view of the Schneider Electric LC1G2654KUEN Contactor showing its physical design and enclosure.

What Buyers Should Verify Before Sourcing

Because this is a high-current device, matching the exact configuration matters. Confirm the coil voltage band (100…250 V AC/DC) against your control supply, and check that the 4 NO pole arrangement fits your circuit. The power terminals accept bar connections with a 32 x 10 mm busbar cross section or lugs-ring terminals up to 185 mm²; control wiring uses push-in terminals from 0.2…2.5 mm² depending on cable stiffness. The contactor mounts on a plate and measures 225 mm high, 185 mm wide, and 226 mm deep, weighing 8.2 kg. Autronexa supplies genuine surplus and refurbished units, each verified against OEM datasheet markings and functionally checked before dispatch. Please verify current lifecycle status and availability with Autronexa before ordering.

Figure 2: Technical layout and connection details for the Schneider Electric LC1G2654KUEN Contactor.

Surplus Advantage for This Contactor

A 385 A frame is not a shelf item most plants keep in depth. When one fails, the choice is often OEM lead time versus a verified surplus unit. Autronexa stocks refurbished and surplus TeSys Giga contactors tested against OEM datasheet specifications and functionally verified by our sourcing team. The wide-band coil means fewer variants to hold, and the 8 Mcycles mechanical durability of this range supports long service between replacements. For maintenance managers, that translates to practical cost savings versus OEM list price without accepting unverified grey-market stock. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is this LC1G2654KUEN a genuine Schneider Electric contactor or a clone?

Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before listing. We supply genuine surplus and refurbished Schneider Electric components, not copies.

What condition will the contactor arrive in?

Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — confirm the condition you need when requesting a quote.

How fast can you ship the LC1G2654KUEN?

Lead time depends on current stock. Contact Autronexa for verified condition and current availability; surplus and refurbished units are ready to ship once confirmed.

Does the wide-band coil work with both AC and DC control circuits?

Yes. The control circuit accepts 100…250 V AC 50/60 Hz or 100…250 V DC, with operational limits of 0.8 Uc Min to 1.1 Uc Max at <60 °C.

Is the LC1G2654KUEN still supported by Schneider Electric?

Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and availability before ordering.

Related & compatible parts

Schneider Electric

140DDI67300C

Genuine surplus Schneider 140DDI67300C Modicon Quantum 24-channel discrete input module — verified, tested, and ready to ship.

In Stock

Schneider Electric

TM258LF42DR

Genuine surplus Schneider Electric TM258LF42DR Modicon M258 controller — 42 I/O, dual-core ARM, Ethernet/CANopen, verified and ready to…

In Stock

Schneider Electric

STBDDI3610K

Genuine surplus STBDDI3610K digital input kit — 6-channel 24 V DC module with base and connectors, verified and…

In Stock

Schneider Electric

140ACI03000

Genuine surplus Schneider Electric 140ACI03000 analog input module — 8 differential channels, 12-bit, verified and ready to ship.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: LC1G2654KUEN

We reply within one business day.

LC1G2654KUEN Quote reply within 1 business day