Technical specifications

Rated supply voltage 100...240 V AC
Discrete I/O number 24
Discrete input number 14 (24 V DC)
Discrete output number 10 relay
Power consumption 25 W at 100...240 V AC
Supply voltage limits 85…264 V
Response time 2 ms turn-on, turn-off
IP degree of protection IP20
Operating temperature 0…55 °C

Description

Overview

When a Modicon M218 logic controller fails on a running line, every hour of downtime adds cost. The Schneider Electric TM218LDA24DRN is a compact base unit with 24 discrete I/O — 14 DC inputs and 10 relay outputs — rated for 100…240 V AC supply. Autronexa supplies this model as genuine surplus and professionally refurbished stock, verified against OEM datasheet markings before dispatch, so you get a practical replacement without the long OEM lead time.

Figure 1: Front view of the Schneider Electric TM218LDA24DRN Logic controller showing its physical design and enclosure.

Technical Specs Breakdown

The supply range of 85…264 V covers common industrial AC feeds with margin, and the 25 W consumption at 100…240 V AC keeps panel loading predictable. Discrete inputs accept 24 V DC, while the 10 relay outputs switch external loads directly. Input impedance is 4700 Ohm for standard inputs and 2800 Ohm for high-speed inputs, with a 2 ms response time for turn-on and turn-off. The IP20 rating suits cabinet mounting, and the 0…55 °C operating range fits most control rooms. Please verify current lifecycle status and availability with Autronexa before ordering.

Figure 2: Technical layout and connection details for the Schneider Electric TM218LDA24DRN Logic controller.

Surplus Advantage

New-from-OEM channels for established Modicon M218 bases often carry long lead times, and grey-market listings rarely confirm what is inside the housing. Autronexa’s refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team before they leave the warehouse. That means the 24 I/O count, the 100…240 V AC supply rating, and the relay output configuration are confirmed on the bench — not assumed from a label. For maintenance teams holding spares budgets, genuine surplus and refurbished stock is a practical middle path: verified condition, clear lead times, and cost savings versus OEM list price. Contact Autronexa with your part number for verified condition and current availability.

Selection & Sourcing Guide

Before ordering, confirm the exact model code on your existing unit — the M218 family includes variants with different I/O mixes, and the 24-discrete-I/O base is not interchangeable with larger configurations. Check whether your application relies on the high-speed inputs (2800 Ohm impedance) or standard inputs (4700 Ohm), since both appear on this model. If you are replacing a unit in a panel, verify the 85…264 V supply limits against your feed and allow for the 0…55 °C ambient rating. Autronexa can cross-reference your existing part number and confirm the revision you need. Surplus and refurbished, ready to ship — ask for the condition report before you commit.

📄 Download Datasheet: TM218LDA24DRN-datasheet.pdf

Frequently asked questions

Is this a genuine Schneider Electric TM218LDA24DRN, or a clone?

Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before listing. We supply genuine surplus and refurbished components only — not grey-market copies.

What condition will the TM218LDA24DRN arrive in?

Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the specific condition report on the unit in stock.

How fast can you ship this logic controller?

Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability — we confirm lead time before you order.

Does the TM218LDA24DRN support the 24 V DC inputs my panel uses?

Yes — the data confirms 14 discrete inputs at 24 V DC, with input impedance of 4700 Ohm for standard inputs and 2800 Ohm for high-speed inputs. Confirm your field wiring against the datasheet before installation.

Is the Modicon M218 series still supported by Schneider Electric?

Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and availability before ordering.

Related & compatible parts

Schneider Electric

TM5SAI4L

Genuine surplus Schneider Electric TM5SAI4L analog input module — 4 channels, 12-bit, verified condition and ready to ship…

In Stock

Schneider Electric

TM5SAI2L

Genuine surplus Schneider Electric TM5SAI2L analog input module — 2 channels, 12-bit, verified condition and clear lead times…

In Stock

Schneider Electric

ATV930D45N4

Genuine surplus Schneider ATV930D45N4 drive — 45 kW ND/37 kW HD, dual-rated, verified condition and ready to ship…

In Stock

Schneider Electric

ATV930C20N4F

Genuine surplus Schneider ATV930C20N4F floor-standing drive, 200 kW ND, IP21 — verified condition, faster than OEM lead time.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: TM218LDA24DRN

We reply within one business day.

TM218LDA24DRN Quote reply within 1 business day