Schneider Electric I/O & Function Modules
Schneider Electric TM3DQ16R
Digital Output Module
Genuine surplus Schneider Electric TM3DQ16R relay output module — 16 channels, 2 A per channel, verified condition and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Module type | Digital output (relay) |
|---|---|
| Channels | 16 |
| Signal type | Relay output, NO (normally open) |
| Output range | 5-30 Vdc / 5-250 Vac (max) |
| Output current | 2 A per channel (max), 7 A per common line |
| Isolation | 500 V AC between output and internal logic; 1500 V AC between channel groups |
| Supply voltage | 24 Vdc (via TM3 bus) |
| Operating temperature | 0...+55 °C |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 90 × 27.4 × 84.6 mm |
Description
How do you add 16 relay outputs to a Modicon M2xx PLC without waiting on a factory lead time? The Schneider Electric TM3DQ16R digital output module answers that question: it is a 16-channel relay output expansion for Modicon M221, M241, M251 and M262 controllers, and Autronexa supplies it as verified surplus or refurbished stock so maintenance teams can close a panel gap quickly.
What This Relay Output Module Does in a Modicon System
The TM3DQ16R is a Modicon TM3 expansion module with 16 normally open relay outputs. Each channel carries up to 2 A, and each common line handles up to 7 A, so the module can drive mixed loads rather than only light signalling circuits. The output range covers 5-30 Vdc and 5-250 Vac (max), which lets one module serve both low-voltage control and AC loads in the same cabinet.
Isolation is specified at 500 V AC between output and internal logic, and 1500 V AC between channel groups. That separation matters when relay channels switch different field circuits and you want to keep groups electrically distinct. Module status and bus status diagnostics are available for troubleshooting, and the removable screw terminal block uses a 3.81 mm pitch for field wiring.
The module draws 37 mA at 5 V DC with all outputs on and 5 mA with all outputs off, supplied via the TM3 bus at 24 Vdc. It measures 90 × 27.4 × 84.6 mm and weighs 0.11 kg, so it fits the standard TM3 expansion footprint without extra panel space.

Why Genuine Surplus Fits This Module
This unit is listed as Active, last verified 2026-09, which means the family is still in service across installed M221, M241, M251 and M262 systems. That installed base is exactly why genuine surplus matters: when a machine is down, a tested pull from a decommissioned panel can be faster than a factory order, and it keeps the original Schneider Electric design rather than a substitute.
Autronexa treats each unit as a sourcing item, not a catalogue line. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team before they are offered. You get a clear condition statement and a current lead time instead of an open-ended estimate. For buyers comparing against OEM list price, surplus and refurbished stock also usually reduces cost on a part that is already proven in the field.

Sourcing Checks Before You Order
Confirm the exact model string on the module label matches unit, since the TM3 range includes other channel counts and output types. Check whether your application needs relay outputs or a transistor variant, and verify that the host controller is one of the compatible Modicon platforms listed above. If the module replaces a failed unit, compare the terminal block and wiring pitch before removal so the existing harness can be reused.
Ask for the condition grade — surplus, refurbished or other — and the current lead time in writing. Autronexa can cross-reference the part number and confirm what is in stock. Please verify current lifecycle status and availability with Autronexa before ordering, and contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric TM3DQ16R, or a clone?
Autronexa verifies units against OEM datasheet markings and part-number cross-reference. The module is supplied as genuine surplus or refurbished stock, not as a grey-market copy.
What condition will the TM3DQ16R arrive in?
The site default condition is Refurbished. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Confirm the exact condition grade for your order with Autronexa.
How fast can you ship the TM3DQ16R?
Lead time depends on current stock. Contact Autronexa for the current lead time and availability before placing the order.
Does this module work with a Modicon M241 controller?
Yes. The compatible platforms listed for this module are Modicon M221, M241, M251 and M262. Confirm your controller model and expansion slot before ordering.
Is the TM3DQ16R still supported by Schneider Electric?
The lifecycle status is listed as Active, last verified 2026-09. Contact Autronexa to verify current OEM support status and availability.
Related & compatible parts
Schneider Electric
ASMBII004
Genuine surplus Schneider ASMBII004 42 m Modicon Quantum drop cable — RS-485 / Modbus Plus, pre-terminated, verified and…
Schneider Electric
TWDAMM3HT
Genuine surplus TWDAMM3HT analog I/O module for Schneider Twido base units — verified condition, sourcing help from Autronexa.
Schneider Electric
170XTS10000
Genuine surplus Schneider Electric 170XTS10000 front labels for Modicon Momentum modules — verified condition, set of 10, ready…
Schneider Electric
140NOE77111
Genuine surplus Schneider 140NOE77111 Ethernet TCP/IP module for Modicon Quantum — verified condition, faster than OEM lead times.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…