Schneider Electric I/O & Function Modules
Schneider Electric TSXDSY08R5A
Discrete Output Module
Genuine surplus Schneider TSXDSY08R5A discrete output module — 8 relay-protected outputs, verified condition, faster than OEM lead time.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Discrete Output Number | 8 |
|---|---|
| Discrete Output Type | Relay Protected |
| Discrete Output Voltage | 24...48 V DC conforming to EN/IEC 61131-2, 19...60 V; 24...240 V AC conforming to EN/IEC 61131-2, 20...264 V |
| Contacts Type and Composition | 2 x 2 C/O + 2 x 2 NO |
| Response Time | < 10 ms (activation), < 15 ms (deactivation) |
| Isolation Resistance | > 10 MOhm at 500 V |
| Current Consumption | 80 mA at 24 V DC rack, 55 mA at 5 V DC |
| Electrical Connection | Screw Terminal Block |
| IP Degree of Protection | IP20 |
Description
The Schneider Electric TSXDSY08R5A is an eight-output discrete relay module from the TSX Micro PLCs family, built for maintenance teams who need to replace a failed output card without waiting on OEM lead times. Genuine surplus stock gives you a verified, tested unit at a fraction of new-list pricing.
What This Module Does in a Running System
This is a discrete output module, not an input card. It drives field devices — contactors, solenoids, indicator lamps, small relays — from a TSX Micro rack. Eight relay-protected outputs handle mixed AC and DC loads, so one card can serve a panel that switches both 24 V DC signals and 240 V AC circuits. The contact composition is 2 x 2 C/O + 2 x 2 NO, which gives you changeover contacts on some channels rather than simple normally-open outputs. For a maintenance engineer, that means fewer interposing relays and a simpler panel to troubleshoot. The module uses a screw terminal block for field wiring, and each common carries a 6.3 A interchangeable fast-blow fuse for overload and short-circuit protection. When a channel goes dead, you check the fuse before condemning the card.

Switching Speed and Isolation You Can Plan Around
Three published figures matter most on a service call. Activation response is under 10 ms, and deactivation is under 15 ms — fast enough for interlocking and sequencing duties on a Micro platform. Isolation resistance is greater than 10 MOhm at 500 V, which keeps rack and field circuits cleanly separated. The output stage also carries RC circuit and Ge-Mov overvoltage protection, so inductive kickback from contactor coils is clamped at the card rather than passed back into the rack. Power dissipation is modest — 0.25 W plus 0.24 W per output at state 1 — so thermal loading in a crowded enclosure stays predictable. Current draw is 80 mA at 24 V DC rack and 55 mA at 5 V DC. The module is marked CE and rated IP20, suited to a clean control cabinet rather than a washdown area.

Why Genuine Surplus Fits This Card
TSX Micro installations are long-lived, and the cards inside them are often the first thing to fail. OEM channels for legacy Schneider modules can mean extended lead times or minimum-order friction. Autronexa stocks genuine surplus and refurbished units, each tested against OEM datasheet specifications and functionally verified by our sourcing team. You get the real card, not a clone, with clear lead times before you commit. For maintenance planners, that shortens the gap between fault finding and a working output channel. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric TSXDSY08R5A, or a copy?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. The module you receive is a genuine Schneider Electric unit, not a clone or grey-market substitute.
What condition will the module arrive in?
Units ship in the site default condition, Refurbished — tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a surplus rather than refurbished unit.
How fast can you ship the TSXDSY08R5A?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability before you place the order.
Does this module work with a TSX Micro rack?
Yes — it belongs to the TSX Micro PLCs family and draws 80 mA at 24 V DC rack or 55 mA at 5 V DC. Confirm your rack slot and wiring with your supplier before installation.
Is the TSXDSY08R5A still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability for this module.
Related & compatible parts
Schneider Electric
140DDI67300C
Genuine surplus Schneider 140DDI67300C Modicon Quantum 24-channel discrete input module — verified, tested, and ready to ship.
Schneider Electric
140ERT85410
Genuine surplus Schneider 140ERT85410 multifunction input module — 32 discrete inputs, 2 isolated groups, verified and ready to…
Schneider Electric
140CRA93101C
Genuine surplus Schneider Electric 140CRA93101C adapter module for Modicon Quantum — verified condition, practical lead times.
Schneider Electric
PC-E984-258
Genuine surplus Schneider PC-E984-258 Modicon CPU with 512 KB memory, 2 Modbus ports, and 512 I/O — verified…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…