Schneider Electric Power Supplies
Schneider Electric TSXPSY1610
Power supply module
Genuine surplus Schneider Electric TSXPSY1610 power supply for Modicon — verified condition, fast lead time, practical sourcing support.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Primary Voltage | 24 V DC (19.2...30 V) |
|---|---|
| Input Current | ≤ 1500 mA at 24 V |
| Inrush Current | 100 A at 24 V |
| I²t on Activation | 12.5 A².s |
| Operating Humidity | 10…95 % without condensation |
| Storage Humidity | 5…95 % without condensation |
| Operating Altitude | 0...6561.68 ft (0...2000 m) |
| IP Degree of Protection | IP20 |
| Pollution Degree | 2 |
| Weight | 1.00 lbs (0.45 kg) |
Description
The Schneider Electric TSXPSY1610 is a 24 V DC power supply module for Modicon series applications, delivering up to 1500 mA input current at 24 V. Maintenance and procurement teams choose genuine surplus or refurbished units to avoid OEM lead times and keep legacy control systems running without compromise on authenticity.
What This Power Supply Does in a Modicon System
The module accepts a primary input voltage of 24 V DC, with an operating range of 19.2 to 30 V, so it tolerates the normal supply variations found on industrial backplanes. At nominal 24 V it draws no more than 1500 mA, and it can absorb an inrush current of up to 100 A — a figure that matters when several modules power up together and the supply must ride through the initial surge. The I²t on activation is 12.5 A².s, which helps engineers assess coordination with upstream protection. Housed with an IP20 degree of protection and a pollution degree 2 rating, the unit is intended for controlled cabinet environments. Its TC (Thermal Classification) protective treatment adds a layer of resilience against thermal stress during operation.

Why Genuine Surplus Makes Sense Here
Modicon installations often stay in service well beyond original procurement cycles, and sourcing a genuine replacement through new-part channels can mean extended lead times. Autronexa stocks surplus and refurbished automation components, and every unit is verified against OEM datasheet markings and functionally checked before it ships. For this power supply, that means you get a part that matches the original 24 V DC input profile — not a grey-market substitute with unknown inrush behaviour. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team, so the 1500 mA input current and 100 A inrush rating you rely on are confirmed, not assumed. When a cabinet is down, that verification step is the difference between a quick restart and a second failure.

Sourcing Checklist for This Module
Before ordering, confirm the exact model reference on your existing unit and match it to the TSXPSY1610 designation. Check whether your application requires the full 19.2 to 30 V input window or operates close to nominal 24 V, and review the cabinet environment against the IP20 and pollution degree 2 ratings. Ask your supplier whether the unit is surplus or refurbished and request the verification details. Autronexa provides practical sourcing help across Schneider Electric and related automation brands, with clear condition notes and current availability. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric TSXPSY1610, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished components, not grey-market copies.
What condition will the TSXPSY1610 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — contact us for current stock and condition notes.
How fast can you ship the TSXPSY1610?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus and refurbished units are ready to ship when in stock.
Does this module work with Modicon series applications?
Yes — the TSXPSY1610 is designed for Modicon series applications with a 24 V DC input range of 19.2 to 30 V. Confirm your specific rack and revision requirements with our sourcing team.
Is the TSXPSY1610 still supported by Schneider Electric?
Lifecycle status is not stated in our current data. Contact Autronexa to verify OEM support status and availability before ordering.
Related & compatible parts
Schneider Electric
TM258LF42DT4L
Genuine surplus Schneider Electric TM258LF42DT4L controller — 42 I/O, Ethernet, CANopen, verified condition and ready to ship.
Schneider Electric
TM258LF42DR
Genuine surplus Schneider Electric TM258LF42DR Modicon M258 controller — 42 I/O, dual-core ARM, Ethernet/CANopen, verified and ready to…
Schneider Electric · BME Series
BMENOC0311C
Schneider BMENOC0311C I/O & Function Modules. Standards: EN/IEC 61131-2; Hazardous Location: class I division 2.
Schneider Electric · Advantys STB
STBACO8220
Genuine surplus Schneider STBACO8220: 2-channel HART analog output, 4-20 mA, 15-bit, hot-swappable. Verified condition, sourcing help from Autronexa.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…