Schneider Electric Power Supplies
Schneider Electric TSXPSY5500M
Power supply module
Genuine surplus Schneider Electric TSXPSY5500M power supply module for TSX Micro PLCs — verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Primary Voltage | 200-240 V AC (190-264 V) / 100-120 V AC (85-140 V) |
|---|---|
| Network Frequency | 50/60 Hz (limits 47-63 Hz) |
| Input Current | 500 mA at 240 V / 1700 mA at 100 V |
| Total Useful Secondary Power | 50 W |
| Secondary Power | 35 W at 5 V DC / 19 W at 24 V DC |
| Operating Temperature | 0 to 60 °C |
| Protection Type | Internal fuse 4 A time-delayed, overload, overvoltage, short-circuit |
| IP Degree of Protection | IP20 |
Description
The Schneider Electric TSXPSY5500M power supply module is a dual-range AC input unit for TSX Micro PLCs, delivering 50 W total useful secondary power. Maintenance and procurement teams choose genuine surplus or refurbished units to avoid OEM lead times without sacrificing verified authenticity.
Product Overview
Industrial control cabinets have evolved from relay logic to compact PLC racks, and the power supply module has become the quiet backbone of that shift. The TSXPSY5500M belongs to the Schneider Electric TSX Micro PLC family, a line many plants still run for discrete control and small process skids. This module converts plant AC into the DC rails the PLC backplane and I/O need, with a total useful secondary power rating of 50 W. It accepts either 200–240 V AC (190–264 V) or 100–120 V AC (85–140 V) at 50/60 Hz, with network frequency limits of 47–63 Hz. Input current is 500 mA at 240 V and 1700 mA at 100 V, and inrush current reaches 38 A at both 240 V and 100 V. Three front LEDs show battery fault (red), presence of voltages (green), and presence of sensor voltage (green), so technicians can confirm rail health without a meter.

Surplus Advantage
Schneider Electric no longer positions the TSX Micro platform as current production, which makes genuine surplus and professionally refurbished modules the practical route for many maintenance budgets. Autronexa stocks verified surplus and refurbished units, each tested against OEM datasheet specifications and functionally verified by our sourcing team. For this model, that means confirming the dual input range, the 50 W secondary output, and the LED signalling before dispatch. Compared with waiting on an OEM allocation, a verified surplus unit often shortens the path back to a running PLC rack. The module also carries an internal 4 A time-delayed fuse plus overload, overvoltage, and short-circuit protection, so a tested unit protects the same downstream hardware as the original.

Selection & Sourcing Guide
Before ordering, confirm the exact model and revision match for your TSX Micro rack, and decide whether a surplus or refurbished unit suits your maintenance policy. Check that your cabinet supply falls within 190–264 V AC or 85–140 V AC, and that the 50 W secondary budget covers your 5 V DC and 24 V DC loads. The module is rated IP20 and operates from 0 to 60 °C at altitudes up to 2000 m. Ask your supplier for the condition grade and any test record. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric TSXPSY5500M, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished modules, not grey-market copies.
What condition will the TSXPSY5500M arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask us for the specific condition grade and test record on the unit reserved for you.
How fast can you ship the TSXPSY5500M?
Lead time depends on current stock. Contact Autronexa for current lead time and availability — surplus and refurbished units are ready to ship once verified.
Does the TSXPSY5500M suit both 120 V and 240 V plant supplies?
Yes. The module accepts 100–120 V AC (85–140 V) or 200–240 V AC (190–264 V) at 50/60 Hz, with network frequency limits of 47–63 Hz, so it covers common industrial supply voltages.
Related & compatible parts
Schneider Electric
TCSEGDB23F24FA
Genuine surplus Schneider TCSEGDB23F24FA Modbus Plus proxy module — Modbus TCP to Modbus Plus gateway with verified condition…
Schneider Electric
iC60N 2P C20
Genuine surplus Schneider Electric iC60N 2P C20 miniature circuit breaker — 20A, C-curve, 6 kA, verified and ready…
Schneider Electric
ATV71H075N4
Genuine surplus Schneider Electric ATV71H075N4 Altivar 71 drive, 0.75 kW, 380–480 V, verified and ready to ship.
Schneider Electric
140QUCMOE
Genuine surplus Schneider Electric 140QUCMOE universal communications module — verified, tested, and ready to ship for Modicon Quantum…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…