Schneider Electric I/O & Function Modules Advantys STB
Schneider Electric STBDRA3290
Relay output module
Genuine surplus Schneider STBDRA3290 relay output module — 2 channels, 7 A each, hot-swappable. Verified condition and current availability from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Module type | Standard relay output module (high current) |
|---|---|
| Channels | 2 |
| Output type | Relay |
| Signal type | 24V DC or 115/230V AC |
| Output current | 7 A per channel |
| Isolation | 1780V AC field-to-bus |
| Hot swapping | Yes |
| Supply voltage | 24V DC (via PDM) |
| I/O base | STBXBA3000 (28.1 mm) |
| PDM | STBPDT3100 (24V DC) |
| Protection rating | IP20 |
| Weight | 0.130 kg |
Description
When a relay output channel fails on a running Advantys STB island, production stops until a replacement is in hand. The Schneider Electric STBDRA3290 is a standard 2-channel high-current relay output module for the Advantys STB distributed I/O family — the genuine part maintenance teams need to restore switching without re-engineering the island. Autronexa supplies verified surplus and refurbished units with clear condition notes and practical lead times.
What This Advantys STB Module Does
The STBDRA3290 is a standard relay output module with two output channels, each rated at 7 A. It switches either 24V DC or 115/230V AC signals, so it can drive contactors, solenoids, and indicator circuits from the same island. Field-to-bus isolation is 1780V AC, which protects the bus side from switching transients on the field wiring. The module is hot-swappable, meaning it can be replaced on a live island without shutting down the other modules. It mounts on the STBXBA3000 I/O base (28.1 mm) and takes 24V DC supply via the STBPDT3100 PDM. The housing carries an IP20 protection rating and weighs 0.130 kg.

Why Genuine Surplus Fits This Discontinued Module
Schneider Electric lists this module as discontinued, superseded by the Modicon X80 range (last verified 2026-09). That status changes the sourcing question: the practical need is a genuine, working module that matches the existing island, not a migration project. Surplus and refurbished stock fills that gap. Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team, so channel switching and isolation are checked before dispatch. For maintenance managers, this means a verified part with a known condition rather than an unknown pull. Because these are surplus and refurbished units, availability moves with stock — confirm current lead time with Autronexa before committing to a maintenance window.
Buyer’s Checklist Before You Order
Start with the base and power hardware: this module requires the STBXBA3000 I/O base and the STBPDT3100 24V DC PDM, so verify both are present in the island. Confirm the load current per channel stays within the 7 A rating and that the switched voltage matches either 24V DC or 115/230V AC. Check that the replacement position is a standard relay output slot, since the module type is fixed. Decide between surplus and refurbished condition based on how critical the circuit is, and ask for the condition note in writing. Finally, because the series is discontinued, please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this STBDRA3290 a genuine Schneider Electric module or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We do not sell grey-market copies. Ask for the verification note with your quote.
What condition will the STBDRA3290 arrive in?
Units ship in the condition stated on your order — our default is refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available when stock allows.
How fast can you ship this relay output module?
Lead time depends on current stock, since the module is discontinued. Contact Autronexa for current lead time and availability before scheduling your maintenance window.
Does the STBDRA3290 need any additional hardware to operate?
Yes. It mounts on the STBXBA3000 I/O base (28.1 mm) and receives 24V DC supply through the STBPDT3100 PDM. Confirm both are present in your island before ordering.
Is the STBDRA3290 still supported by Schneider Electric?
Schneider Electric lists this module as discontinued and superseded by the Modicon X80 range (last verified 2026-09). Contact Autronexa to verify OEM support status and current availability.
Related & compatible parts
Schneider Electric
490NAC0100
Genuine surplus Schneider 490NAC0100 hot standby copper adapter for Modicon M580 redundant processors — verified condition, ready to…
Schneider Electric
140CRA93100
Genuine surplus Schneider Electric 140CRA93100 RIO drop adaptor module for Modicon Quantum — verified condition, cost-saving alternative to…
Schneider Electric
ATV610C11N4Z
Genuine surplus Schneider ATV610C11N4Z 110 kW drive — verified condition, faster lead time than OEM, practical sourcing support.
Schneider Electric
140XBE10000
Genuine surplus Schneider Electric 140XBE10000 backplane expander for Modicon Quantum 12...16-slot backplanes — verified condition, ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…