Series Advantys STB
Protocols CANopen
Built-in ports 9-pin SUB-D (DB-9S)
Supply voltage 24V DC
Addressable I/O modules max 32 per island
Protection rating IP20
Dimensions (H×W×D) 128.3 × 70 × 40 mm
Weight 0.145 kg
Lifecycle Discontinued (superseded by Modicon X80 range) (Last verified: 2026-09)

Description

When a CANopen island drops offline, the bottleneck is usually the network interface module — and for Advantys STB systems the STBNCO1010 is the part that keeps the bus talking to up to 32 I/O modules. Autronexa supplies this Schneider Electric NIM as genuine surplus, verified before dispatch, so maintenance teams can restore the island without waiting on an OEM allocation queue.

What This Network Interface Module Does in an STB Island

The module is the head of an Advantys STB island. It presents the island to the CANopen network through a single 9-pin SUB-D (DB-9S) port and manages addressing for as many as 32 I/O modules downstream. That architecture matters when a machine has one failed NIM but a full rack of healthy I/O: replacing the head unit restores the whole island instead of forcing a line-by-line rebuild. The unit runs from a 24V DC supply and carries an IP20 protection rating, which suits cabinet-mounted installations. Its 128.3 × 70 × 40 mm housing and 0.145 kg weight match the standard STB footprint, so it drops into the existing slot and wiring envelope. Because the series is discontinued and superseded by the Modicon X80 range, matching the original head module is often the least disruptive path for an existing machine.

Figure 1: Front view of the Schneider Electric STBNCO1010 Module showing its physical design and enclosure.

Why Surplus Beats Waiting on a Discontinued Series

Schneider Electric has discontinued the Advantys STB line, and that changes the sourcing math. OEM channels may quote long allocations or push a migration to Modicon X80 — a project, not a spare-part swap. Genuine surplus and refurbished units keep existing islands running while a migration is planned on your schedule. Each unit we offer is tested against OEM datasheet specifications and functionally verified by our sourcing team before it ships. For a head module that must hold a CANopen conversation with 32 downstream modules, that verification is the difference between a plug-in fix and a second outage. Buyers also avoid paying new-list pricing for a platform the OEM no longer builds.

Sourcing Checklist Before You Order

Confirm three things before committing. First, verify the exact model and revision against the label on your failed unit — the STB family has multiple head variants, and only the CANopen version fits a CANopen network. Second, confirm the downstream module count and power budget of your island so the replacement matches the installed configuration. Third, agree the condition grade up front: surplus and refurbished units are functionally verified, but cosmetic wear varies, so ask for photos and the test record if appearance matters in your panel. Autronexa can cross-reference your part number against OEM markings and confirm current availability. Please verify current lifecycle status and availability with Autronexa before ordering.

Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: STBNCO1010-datasheet.pdf

Frequently asked questions

Is this STBNCO1010 a genuine Schneider Electric module or a copy?

Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it is listed. We supply genuine surplus and refurbished Schneider Electric automation components, not clones.

What condition will the module arrive in?

Units are supplied in the site default condition, Refurbished, meaning tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask for the test record and photos if cosmetic condition matters for your panel.

How fast can you ship the STBNCO1010?

Lead time depends on current stock. Contact Autronexa for the current lead time and availability before placing your order.

Does this module work with my existing Advantys STB island?

It is the CANopen network interface head for Advantys STB and addresses up to 32 I/O modules per island over a 9-pin SUB-D (DB-9S) port. Confirm your island uses CANopen and match the revision on your failed unit before ordering.

Is the Advantys STB series still supported by Schneider Electric?

The series is discontinued and superseded by the Modicon X80 range, per our last verification in 2026-09. Contact Autronexa to confirm OEM support status and current availability.

Related & compatible parts

Schneider Electric

TSX3710101

Genuine surplus Schneider TSX3710101 micro PLC, verified and ready to ship. 100-240 V AC, 8 analog inputs, Modbus…

In Stock

Schneider Electric

ATV320U30N4W

Genuine surplus Schneider ATV320U30N4W 3 kW IP66 drive with C2 EMC filter — verified condition and clear lead…

In Stock

Schneider Electric

140NOE77110

Genuine surplus Schneider 140NOE77110 Ethernet TCP/IP module for Modicon Quantum — verified, tested, and ready to ship.

In Stock

Schneider Electric

TM3DQ16TG

Genuine surplus Schneider Electric TM3DQ16TG 16-channel transistor output module — verified condition, faster than OEM lead time.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: STBNCO1010

We reply within one business day.

STBNCO1010 Quote reply within 1 business day