Schneider Electric I/O & Function Modules Advantys STB

Schneider Electric STBPDT3100

Module

Manufacturer: Schneider Electric Part Number: STBPDT3100

Genuine surplus STBPDT3100 PDM for Advantys STB — 24V DC, verified condition, faster than OEM lead time.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Supply voltage 24V DC (19.2-30V)
Max current for inputs 4 A @30 °C, 2.5 A @60 °C
Max current for outputs 8 A @30 °C, 5 A @60 °C
Sensor/actuator bus voltage 19.2-30V DC
Overcurrent protection 5 A time-delayed fuse (inputs), 10 A time-delayed fuse (outputs)
Reverse polarity protection Yes (on actuator bus)
Nominal consumption 0 mA on 5V logic power supply
Mounting base STBXBA2200 (18.4 mm)
Protection rating IP20
Hot plug/plug out with power on No

Description

The STBPDT3100 is a Schneider Electric Advantys STB power distribution module that feeds 24V DC to a distributed I/O island, and maintenance teams turn to genuine surplus units because the line is discontinued and OEM replacements now sit in the Modicon X80 range. Autronexa supplies this module as verified surplus, giving you a tested part without the migration cost of re-engineering an existing STB slice.

Where This PDM Fits in an Advantys STB Island

The Advantys STB series splits power and I/O across separate modules, and this power distribution module handles the supply side. It accepts 24V DC across a 19.2–30V window, so a sagging or slightly high supply rail does not immediately drop the island. The module draws 0 mA from the 5V logic power supply, which means it adds distribution capacity without loading the logic budget — a practical saving when you are squeezing more slices onto an existing island instead of buying a larger supply.

Current capacity is split by temperature, and that split drives real cost decisions. Inputs carry 4 A at 30 °C but only 2.5 A at 60 °C; outputs carry 8 A at 30 °C and 5 A at 60 °C. A cabinet running hot effectively derates the module, so thermal planning is part of the electrical budget. Protection is built in: a 5 A time-delayed fuse on inputs and a 10 A time-delayed fuse on outputs, plus reverse polarity protection on the actuator bus. The grounding terminal tolerates 30 A for 2 minutes. The module clips onto the STBXBA2200 mounting base (18.4 mm), and it does not support hot plug or plug-out with power on — plan shutdowns accordingly rather than risking a live swap.

Figure 1: Front view of the Schneider Electric STBPDT3100 Module showing its physical design and enclosure.

Surplus Advantage for a Discontinued STB Module

Schneider Electric lists this module as discontinued, superseded by the Modicon X80 range. That status is the core sourcing problem: a like-for-like replacement is no longer built new, and moving to X80 means new bases, new wiring and revalidation time. Genuine surplus stock keeps the existing island running on its original platform, and every unit Autronexa supplies is tested against OEM datasheet specifications and functionally verified by our sourcing team. You get a verified part with a clear lead time instead of an open-ended migration project.

Sourcing Checklist Before You Order

Confirm the mounting base — this module is specified for the STBXBA2200 at 18.4 mm, and a mismatched base is the most common reason a replacement will not seat. Check the cabinet’s actual operating temperature against the derated current figures above, because a unit sized at 30 °C may not carry the same load at 60 °C. Verify the exact model string, since the STB family uses closely related part numbers. Decide whether you need surplus or refurbished condition and ask for the grading in writing. Please verify current lifecycle status and availability with Autronexa before ordering.

📄 Download Datasheet: STBPDT3100-datasheet.pdf

Frequently asked questions

Is this STBPDT3100 a genuine Schneider Electric module or a copy?

Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it is listed. This is genuine surplus Schneider Electric stock, not a grey-market clone.

What condition will the module arrive in?

Units ship in the condition stated on your quote. Our default is refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask for the condition grading in writing when you request a quote.

How fast can you ship the STBPDT3100?

Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; we confirm the lead time before you commit.

Which mounting base does this power distribution module need?

The datasheet specifies the STBXBA2200 base at 18.4 mm. Confirm your existing base matches before ordering, since a mismatched base will prevent the module from seating correctly.

Is the STBPDT3100 still supported by Schneider Electric?

Schneider Electric lists this module as discontinued and superseded by the Modicon X80 range. Contact Autronexa to verify OEM support status and current availability of genuine surplus units.

Related & compatible parts

Schneider Electric

TM3DI32K

Genuine surplus Schneider TM3DI32K discrete input module — 32 sinking/sourcing inputs, 24V DC, HE10 connector. Verified condition, ready…

In Stock

Schneider Electric

BMEH586040

Genuine surplus Schneider BMEH586040 redundant processor for Modicon M580 — verified condition, faster lead times than OEM.

In Stock

Schneider Electric

ATV930C13N4

Genuine surplus Schneider ATV930C13N4 drive — 132 kW ND/110 kW HD, dual-rated, verified condition, faster than OEM lead…

In Stock

Schneider Electric

SR3B261JD

Genuine surplus SR3B261JD Zelio Logic smart relay: 26 I/O, 12V DC, verified condition and faster sourcing than OEM…

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: STBPDT3100

We reply within one business day.

STBPDT3100 Quote reply within 1 business day