Bently Nevada Cables & Connectors

Bently Nevada 107770-01-02

Cable Exit Fitting Option:02= 1/2-14 NPT explosion-proof

Manufacturer: Bently Nevada Part Number: 107770-01-02

Genuine Bently Nevada 107770-01-02 velocity transducer housing with 1/2-14 NPT explosion-proof cable exit, factory packed and verified.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Cable Exit Fitting Option 02 = 1/2-14 NPT explosion-proof
Mounting Thread Option 01 = Unthreaded
Housing Model 107770 – Velocity Transducer Housing – CENELEC approved
Hazardous Area Rating CENELEC Zone 1, Group IIC
Condition New & Original in Factory Packing
Factory Warranty 12 Months
RoHS Compliance RoHS Directive 2011/65/EU

Description

The Bently Nevada 107770-01-02 is a CENELEC-approved velocity transducer housing with a 1/2-14 NPT explosion-proof cable exit fitting (Option 02) and an unthreaded mounting (Option 01). Maintenance teams specify it when a 330500 Velomitor Sensor must be installed in Zone 1, Group IIC hazardous areas, because the factory-preinstalled 21128 housing removes field assembly work and its associated labour cost. Sourcing a genuine unit protects the integrity of the measurement loop and avoids repeat installation expense.

What This Housing Does in a Monitoring Loop

The 107770-01-02 combines the 330500 Velomitor Sensor and the 21128 Housing in a single factory-assembled unit. That preinstallation matters for cost control: the sensor-to-housing interface is set at the factory, so technicians do not spend shift time aligning and sealing components on site. The unthreaded mounting option suits installations where the housing is secured by other means, and the 1/2-14 NPT cable exit accepts standard explosion-proof conduit fittings. Because the assembly is rated for CENELEC Zone 1, Group IIC applications, it supports vibration monitoring in hazardous process areas without a separate enclosure. Each avoided field assembly step reduces both labour hours and the risk of a rework call-out.

Figure 1: Front view of the Bently Nevada 107770-01-02 Cable Exit Fitting Option:02= 1/2-14 NPT explosion-proof showing its physical design and enclosure.

Why Genuine Surplus Makes Commercial Sense

Autronexa supplies this housing as genuine surplus and refurbished stock, verified against OEM datasheet markings and part-number cross-reference. For a CENELEC-approved housing, authenticity is not a cosmetic concern: an unverified clone can compromise the hazardous-area rating and force a costly re-certification review. Genuine surplus units also shorten the procurement cycle compared with OEM factory lead times, which keeps maintenance budgets predictable when a transducer housing fails unexpectedly. Every unit is functionally checked before dispatch, and the 12-month factory warranty stated for this configuration adds a layer of cost protection that grey-market stock rarely offers.

Figure 2: Technical layout and connection details for the Bently Nevada 107770-01-02 Cable Exit Fitting Option:02= 1/2-14 NPT explosion-proof.

Sourcing Checks Before You Order

Confirm three details before committing: the cable exit option must read 02 for the 1/2-14 NPT explosion-proof fitting, the mounting thread option must read 01 for unthreaded, and the assembly must be the factory combination of the 330500 sensor and 21128 housing. Ask for the condition grading in writing, since this configuration is listed as new and original in factory packing. Verify that the CENELEC Zone 1, Group IIC rating matches your area classification, and check cable type A or B compliance with EN 60079-25 against your entity parameters. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: 107770-01-02-datasheet.pdf

Frequently asked questions

Is the Bently Nevada 107770-01-02 a genuine part or a clone?

Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before dispatch. The 107770-01-02 is supplied as genuine surplus or refurbished stock, never as an unverified copy.

What condition will the 107770-01-02 arrive in?

This configuration is listed as new and original in factory packing, with a 12-month factory warranty. Contact Autronexa to confirm the current condition grading of available units.

How fast can Autronexa ship the 107770-01-02?

Lead time depends on current verified stock. Contact Autronexa with your part number for current availability and a confirmed dispatch date.

Does the 107770-01-02 suit Zone 1, Group IIC hazardous areas?

Yes. The housing is CENELEC approved and rated for Zone 1, Group IIC applications, with a 1/2-14 NPT explosion-proof cable exit. Confirm your area classification and entity parameters before installation.

Related & compatible parts

Bently Nevada · 3500

3500/15 133300-01

Bently Nevada 3500/15 133300-01 Low Voltage DC Power Input Module. Input: voltage 20 to 30 Vdc; Power: supply…

Available on request

Bently Nevada · 31000 / 32000 Series

31000-16-05-00-037-03-02

Bently Nevada 31000-16-05-00-037-03-02 Proximity Probe Housing. Probe Cable Length: 0.5 m (20 in); O-Ring Material: Neoprene®.

Available on request

Bently Nevada · 31000 / 32000 Series

31000-16-05-00-035-02-02

Bently Nevada 31000-16-05-00-035-02-02 Proximity Probe Housing. Fittings: Two 3/4-14 NPT fittings, one plug; O-Ring Material: Neoprene®.

Available on request

Bently Nevada

105M6193-03

Genuine surplus Bently Nevada 105M6193-03 stainless steel housing for 2300 series, verified for hazardous-area use and ready to…

In Stock

News & guides for Bently Nevada

View all articles

Request a quote for this part

Part number: 107770-01-02

We reply within one business day.

107770-01-02 Quote reply within 1 business day