Bently Nevada Cables & Connectors
Bently Nevada 107770-02-02
Cable Exit Fitting Option02= 1/2-14 NPT explosion-proof
Genuine Bently Nevada 107770-02-02 velocity transducer housing with 3/4-14 NPT mounting and 1/2-14 NPT explosion-proof cable exit, CENELEC approved.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Condition | New & Original in Factory Packing |
|---|---|
| Factory Warranty | 12 Months |
| Model | 107770 – Velocity Transducer Housing – CENELEC approved |
| Mounting Thread Option | 02 = 3/4-14 NPT |
| Cable Exit Fitting Option | 02 = 1/2-14 NPT explosion-proof |
| Hazardous Area Rating | CENELEC Zone 1, Group IIC |
| Compliance | RoHS Directive 2011/65/EU |
Description
The Bently Nevada 107770-02-02 is a CENELEC-approved velocity transducer housing that combines a 330500 Velomitor Sensor with a 21128 Housing preinstalled at the factory. It suits maintenance and procurement teams that need a genuine, correctly configured housing for Zone 1, Group IIC hazardous-area velocity monitoring without waiting on a full OEM build cycle. Autronexa supplies this unit as new and original in factory packing, so the configuration you receive matches the part number exactly.
What the 107770-02-02 Housing Provides
This housing is more than a mechanical enclosure. It packages the 330500 Velomitor Sensor and the 21128 Housing as one factory-assembled unit, which removes the risk of mixing a sensor with an incompatible housing in the field. This unit variant is defined by two thread options: a 3/4-14 NPT mounting thread and a 1/2-14 NPT explosion-proof cable exit fitting. Because both threads are fixed by the part number, buyers should confirm their conduit and mounting interfaces before ordering. The assembly is rated for CENELEC Zone 1, Group IIC hazardous-area applications and falls under RoHS Directive 2011/65/EU.

Hazardous-Area Installation Considerations
Safe use in classified areas depends on the entity parameters and cable selection, not on the housing alone. For Zone 0/1, the equipment must be connected to equipment that meets the listed entity parameters, and Type A or B cables in compliance with EN 60079-25 must respect the cable parameters listed with those entity parameters. For Zone 2, the supply electrical parameters must not exceed the values in the applicable tables. These conditions come from the manufacturer’s hazardous-area documentation, so always work from the official manual during installation and inspection. Periodic inspection of the cable exit fitting and mounting thread helps catch loosening or corrosion before it affects signal integrity.

Why Genuine Surplus Makes Sense Here
Hazardous-area velocity monitoring leaves little room for unverified hardware. A clone housing may fit the threads but cannot be assumed to meet the same CENELEC Zone 1, Group IIC conditions of safe use. Autronexa focuses on genuine surplus and refurbished automation components, and this unit is offered as new and original in factory packing with a 12-month factory warranty. That combination gives maintenance planners a practical alternative when an OEM lead time threatens a scheduled outage. Every unit is checked against OEM datasheet markings and part-number cross-reference before it ships, and our sourcing team can confirm current availability and lead time for your site.
Choosing the Right Thread Configuration
The 107770 family uses option codes to define mounting and cable exit threads, so the suffix matters. This unit carries a 3/4-14 NPT mounting thread and a 1/2-14 NPT explosion-proof cable exit. Before ordering, verify the mating conduit size, the required hazardous-area rating, and whether your installation calls for the 330500 Velomitor Sensor preinstalled as part of the assembly. If your drawing references a different option code, contact Autronexa with the full part number so the team can confirm the correct configuration rather than substitute a near match.
Frequently asked questions
Is this a genuine Bently Nevada 107770-02-02, or a clone?
Autronexa supplies this unit as new and original in factory packing. Each housing is checked against OEM datasheet markings and part-number cross-reference before shipment, so the 3/4-14 NPT mounting and 1/2-14 NPT cable exit match the 107770-02-02 configuration.
What condition will the 107770-02-02 arrive in?
This unit is listed as new and original in factory packing and carries a 12-month factory warranty. Contact Autronexa if you need the current condition grading confirmed for a specific order.
How fast can Autronexa ship the 107770-02-02?
Lead time depends on current stock at the time of your request. Contact Autronexa with your part number for verified condition and current availability before committing to an outage schedule.
Does the 107770-02-02 suit Zone 1, Group IIC hazardous areas?
Yes. The 107770 housing is CENELEC approved and rated for Zone 1, Group IIC applications. Safe use still requires connection to equipment meeting the listed entity parameters and Type A or B cables compliant with EN 60079-25.
Related & compatible parts
Bently Nevada
3500/15-05-05-00
The Bently Nevada 3500/15 is the power supply module for the 3500 machinery protection system, delivering regulated power…
Bently Nevada · 31000 / 32000 Series
31000-16-05-15-040-02-02
Bently Nevada 31000-16-05-15-040-02-02 Proximity Probe Housing. Standoff Adapter: 15 Minimum length 1.5 in (38 mm); Strength: (typical).
Bently Nevada
107770-03-01
Genuine Bently Nevada 107770-03-01 velocity transducer housing with 1/2-14 NPT mounting and cable exit plug, CENELEC approved for…
Bently Nevada · 3500/40M
3500/40M-01-00
Bently Nevada 3500/40M-01-00 Proximitor/Seismic Monitor. Hazardous Area Approval: 00 — None; Category: Monitor order code.
News & guides for Bently Nevada
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Bently Nevada 3500/91 EGD Gateway: Mark VIe Interface, Slots and Limits
TL;DR: The Bently Nevada 3500/91 is the EGD (Ethernet Global Data) communication gateway for a 3500 rack. It publishes rack,…
Bently Nevada 3500/50M Tachometer Module: Channels, Alarms, Spares
The 3500/50M is a two-channel speed module with no onboard relay contacts and no numeric display. What it measures, how…
Bently Nevada Orbit 60 conneX: Bidirectional DCS Interface
Bently Nevada’s Orbit 60 condition monitoring platform connects to the rest of the plant through conneX—a bidirectional digital interface that…
Bently Nevada 3500 Machinery Protection System: Specifications and Configuration
The Bently Nevada 3500 Machinery Protection System is a rack-based, modular monitoring and protection platform for rotating machines such as…
Bently Nevada 3300 XL Proximity Probe: Materials, Ratings, and Mounting
The Bently Nevada 3300 XL proximity transducer system measures radial vibration, axial position, and phase reference on rotating machinery shafts.…
Bently Nevada 32000 Metric Probe Housing: Construction and Protection Ratings
The Bently Nevada 32000 Metric Proximity Probe Housing is a mounting assembly that secures a 3300 XL proximity probe in…