Schneider Electric I/O & Function Modules
Schneider Electric 140AIO33000
Intrinsically Safe Analog Output Module
Genuine surplus Schneider Electric 140AIO33000 intrinsically safe analog output module — 8 outputs, verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Number of Outputs | 8 |
|---|---|
| Output Ranges | 0...20 mA, 0...25 mA, 4...20 mA |
| Accuracy | ±0.2% of full scale at 25°C |
| Maximum Loop Resistance | 500 Ohm |
| Update Time | 4 ms |
| Setting Time | 1 ms to ±0.1% of final value |
| Power Dissipation | 12.5 W |
| Bus Current Requirement | 2.5 A |
| Operating Temperature | 0...60 °C |
| Marking | CE, II1 G/D-EEx ia IIC |
Description
The Schneider Electric 140AIO33000 is an intrinsically safe analog output module from the Modicon Quantum series, built for control systems in hazardous zones. Maintenance and procurement teams choose genuine surplus or refurbished units to avoid OEM lead times while keeping verified authenticity and clear condition reporting. Autronexa supplies this module with practical sourcing support and current availability confirmed before order.
What This Module Does in a Quantum System
The module provides eight analog output channels for the Modicon Quantum automation platform. It supports 0…20 mA, 0…25 mA and 4…20 mA output ranges, with 4…20 mA available at 15-bit resolution. Accuracy is ±0.2% of full scale at 25°C, and linearity stays within ±1 LSB. An update time of 4 ms and a setting time of 1 ms to ±0.1% of final value suit control loops that need repeatable response. An internal fuse protects the module, and isolation between channels and bus is rated 1780 Vrms for 60 s AC. The unit is marked CE and II1 G/D-EEx ia IIC, with hazardous-location certifications including Class 1, Division 1 groups A, B, C and SIRA 02ATEX2345X. Hot swapping is not allowed per intrinsic safety standards.

Surplus Advantage for This Safety-Rated Module
Intrinsically safe modules often carry long OEM lead times because they sit in a specialised certification category. Genuine surplus and professionally refurbished units give maintenance teams a practical alternative. Autronexa verifies each module against OEM datasheet markings and part-number cross-reference, then functionally checks it before dispatch. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. For this model, the relevant checks include the eight output channels, the ±0.2% accuracy at 25°C, the 500 Ohm maximum loop resistance and the internal fuse. Because the module carries hazardous-area markings, buyers should confirm the exact certification suffix and revision match their existing installation before ordering.

Sourcing Checks Before You Order
Confirm the exact model and any revision notes on your existing module, then match the certification marking to your hazardous-zone classification. Decide whether your application needs surplus, refurbished or another condition grade, and verify that the 4…20 mA range and 15-bit resolution fit your loop requirements. The module operates from 0…60 °C ambient and stores from -40…85 °C, with 95% relative humidity without condensation. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 140AIO33000, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference. The module carries the CE and II1 G/D-EEx ia IIC markings stated in the datasheet, and we confirm these before dispatch.
What condition will the 140AIO33000 arrive in?
Our default condition is refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available depending on stock. Contact Autronexa for the current condition grade of this specific module.
How fast can you ship the 140AIO33000?
Lead time depends on current stock and condition grade. Contact Autronexa for current lead time and availability before placing your order.
Does this module work with Modicon Quantum systems?
Yes, it is part of the Modicon Quantum automation platform and supports Concept V2.2 and above, ProWORX and Unity Pro software designations. Confirm your exact system revision with Autronexa before ordering.
Is the 140AIO33000 still supported by Schneider Electric?
Lifecycle status is not stated in our datasheet data. Contact Autronexa to verify OEM support status and current availability.
Related & compatible parts
Schneider Electric
BMEP584040S
Genuine surplus BMEP584040S safety processor — verified, tested, and ready to ship from Autronexa.
Schneider Electric
BMENUA0100
Genuine surplus Schneider Electric BMENUA0100 serial module for Modicon M580 — verified condition, practical lead times, and sourcing…
Schneider Electric
140DDI84100
Genuine surplus Schneider Electric 140DDI84100 Modicon Quantum 16-point DC input module — verified, tested, and ready to ship…
Schneider Electric
BMXRMS128MPF
Genuine surplus Schneider Electric BMXRMS128MPF 128MB SD flash memory card for Modicon M340 processors — verified condition, ready…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…