Schneider Electric I/O & Function Modules

Schneider Electric 140ARI03010

Analogue input module

Manufacturer: Schneider Electric Part Number: 140ARI03010

Genuine surplus Schneider 140ARI03010 analog input module for Modicon Quantum — 8 differential channels, verified condition, ready to ship.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Analogue input number 8
Input type Differential
Analogue input resolution 13 bits
Input impedance >= 10 MOhm
Absolute accuracy error 0.1 °C
Update time 1200 ms 3 wires; 640 ms 2 wires/4 wires
Bus current requirement 200 mA
Power dissipation 1 W
Module format Standard
Net weight 0.7 lb(US) (0.3 kg)

Description

When a temperature-critical process loses its analog input card, every hour of downtime compounds. The Schneider Electric 140ARI03010 is an 8-channel analog input module for the Modicon Quantum platform, built for Pt 100/200/500/1000 and Ni 100/200/500/1000 temperature probes. Maintenance teams and integrators choose genuine surplus or refurbished units for this model because OEM lead times can stretch while a verified, tested module sits ready to ship.

What This Module Does in a Quantum Rack

The 140ARI03010 occupies a standard slot in a Modicon Quantum automation platform and accepts eight differential temperature-probe inputs. It resolves readings to 13 bits and maintains input impedance of at least 10 MOhm, so it does not load the sensor circuit. Absolute accuracy error is 0.1 °C, with linearity error of +/- 0.01 % full scale and +/- 0.5 °C. Update time is 1200 ms for 3-wire probes and 640 ms for 2-wire or 4-wire configurations. The module draws 200 mA from the bus and dissipates 1 W. Front-panel LEDs show bus activity, external faults, and per-channel on/fault status, which helps technicians diagnose a probe loop without pulling the card.

Figure 1: Front view of the Schneider Electric 140ARI03010 Analogue input module showing its physical design and enclosure.

Surplus Advantage for This unit

Schneider Electric lists this module under the Modicon Quantum range, and the data carries no lifecycle status — so please verify current lifecycle status and availability with Autronexa before ordering. That uncertainty is exactly where surplus sourcing earns its place. Autronexa supplies genuine surplus and refurbished units tested against OEM datasheet specifications and functionally verified by our sourcing team. You avoid the long OEM backlog and full list price while still receiving a module whose markings and part number cross-reference check out. For plants running existing Quantum racks, this is a practical way to keep spare capacity without redesigning the control system.

Figure 2: Technical layout and connection details for the Schneider Electric 140ARI03010 Analogue input module.

Sourcing Checks Before You Order

Confirm three things before committing. First, match the exact part number and any revision notes on the existing card — Quantum racks are sensitive to module format and addressing. Second, confirm your probe type and wiring: the module supports 3-wire, 2-wire, and 4-wire connections, and update time differs between them. Third, decide between surplus and refurbished condition based on how critical the loop is. Autronexa can walk through these details with you; contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: 140ARI03010-datasheet.pdf

Frequently asked questions

Is this a genuine Schneider Electric 140ARI03010, or a clone?

Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished modules, not grey-market copies.

What condition will the 140ARI03010 arrive in?

Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — confirm the exact condition with Autronexa when you request a quote.

How fast can you ship the 140ARI03010?

Lead time depends on current stock. Contact Autronexa for the current lead time and availability; surplus and refurbished units are typically ready to ship faster than an OEM factory order.

Does this module work with Pt 100 and Ni 100 probes?

Yes. The data lists support for Pt 100, Pt 200, Pt 500, Pt 1000 and Ni 100, Ni 200, Ni 500, Ni 1000 temperature probes across the stated temperature ranges. Confirm your specific probe range and wiring against the module's input type before ordering.

Is the 140ARI03010 still supported by Schneider Electric?

The source data does not state lifecycle status. Contact Autronexa to verify OEM support status and current availability before you plan a maintenance window.

Related & compatible parts

Schneider Electric

TM251MESC

Genuine surplus Schneider TM251MESC logic controller — verified condition, faster lead times than OEM, and expert sourcing support.

In Stock

Schneider Electric

140DDO35310C

Genuine surplus Schneider Electric 140DDO35310C Modicon Quantum 32-channel discrete output module — verified condition, sourcing support from Autronexa.

In Stock

Schneider Electric

TM3DQ32UK

Genuine surplus Schneider TM3DQ32UK: 32 NPN transistor outputs, 24 V DC, HE-10. Verified condition, ready to ship.

In Stock

Schneider Electric

140DIO33000C

Genuine surplus Schneider Electric 140DIO33000C intrinsically safe discrete output module — verified condition, ready to ship.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: 140ARI03010

We reply within one business day.

140ARI03010 Quote reply within 1 business day